Impact of electronic imaging on clinician behavior in the urgent care setting

被引:2
作者
Mattern, CWT [1 ]
Erickson, BJ [1 ]
King, BF [1 ]
Okryznski, TW [1 ]
机构
[1] Mayo Med Ctr, Rochester, MN 55905 USA
关键词
D O I
10.1007/BF03168785
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Although it is intuitively valuable that more expedient delivery of radiographic images and reports to clinicians would improve patient care, it is important to document these outcomes to validate further advances in these areas. We evaluated the care of 215 patients seen at a walk-in clinic to determine what benefit digital imaging is to the patient. Cohorts consisted of all patients for whom specified radiology examinations were ordered during a 7-day period. The first cohort was recruited when analog films were used. The second cohort received examinations performed with computed radiography (CR) acquisition and computer display, which had been in use for 2 years. Patients were categorized as to the type of study they received, as well as whether a staff radiologist was immediately available to read the study. Clinical behavior was characterized by outcome measures of time to final diagnosis, time to final treatment, and need for follow-up. Our analysis demonstrated a reduction in time to final diagnosis that was better appreciated during the times when a staff radiologist was not immediately available. It also suggested that greater time reductions were seen for patients who received extremity examinations than those who received chest, sinus, or rib films. These data suggest that digital imaging is a useful tool to improve clinical outcome of patients seen in the acute care setting, Copyright (C) 1999 by W.B. Saunders Company.
引用
收藏
页码:148 / 151
页数:4
相关论文
共 11 条
[1]   Radiology report times: Impact of picture archiving and communication systems [J].
Bryan, S ;
Weatherburn, G ;
Watkins, J ;
Roddie, M ;
Keen, J ;
Muris, N ;
Buxton, MJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1153-1159
[2]   EFFECT OF A DIGITAL IMAGING NETWORK ON PHYSICIAN BEHAVIOR IN AN INTENSIVE-CARE UNIT [J].
DESIMONE, DN ;
KUNDEL, HL ;
ARENSON, RL ;
SESHADRI, SB ;
BRIKMAN, IS ;
KHALSA, SS ;
DAVEY, MJ ;
BRISBON, NE .
RADIOLOGY, 1988, 169 (01) :41-44
[3]   Prospective study of PACS: Information flow and clinical action in a medical intensive care unit [J].
Kundel, HL ;
Seshadri, SB ;
Langlotz, CP ;
Lanken, PN ;
Horii, SC ;
Nodine, CF ;
Polansky, M ;
Feingold, E ;
Brikman, I ;
Bozzo, M ;
Redfern, R .
RADIOLOGY, 1996, 199 (01) :143-149
[4]   Accuracy of bedside chest hard-copy screen-film versus hard- and soft-copy computed radiographs in a medical intensive care unit: Receiver operating characteristic analysis [J].
Kundel, HL ;
Gefter, W ;
Aronchick, J ;
Miller, W ;
Hatabu, H ;
Whitfill, CH ;
Miller, W .
RADIOLOGY, 1997, 205 (03) :859-863
[5]   Electronic imaging impact on image and report turnaround times [J].
Mattern, CWT ;
King, BF ;
Hangiandreou, NJ ;
Swenson, A ;
Jorgenson, LL ;
Webbles, WE ;
Okrzynski, TW ;
Erickson, BJ ;
Williamson, B ;
Forbes, GS .
JOURNAL OF DIGITAL IMAGING, 1999, 12 (02) :155-159
[6]   EXACT SIGNIFICANCE TESTING TO ESTABLISH TREATMENT EQUIVALENCE WITH ORDERED CATEGORICAL-DATA [J].
MEHTA, CR ;
PATEL, NR ;
TSIATIS, AA .
BIOMETRICS, 1984, 40 (03) :819-825
[7]   Direct digital versus conventional film screen radiography of the musculoskeletal system [J].
Piraino, DW ;
Davros, WJ ;
Lieber, M ;
Richmond, BJ ;
Schils, JP ;
Recht, MP ;
Grooff, PN ;
Belhobek, GH .
JOURNAL OF DIGITAL IMAGING, 1998, 11 (03) :172-173
[8]   Comparison between conventional radiography and thoravision in the study of the normal chest [J].
Procacci, C ;
Minniti, S ;
Biondetti, PP ;
Moore, F ;
Caumo, F ;
Ternullo, S ;
Carbognin, G ;
BergamoAndreis, IA .
JOURNAL OF DIGITAL IMAGING, 1997, 10 (03) :183-184
[9]   PACS workstation usage and patient outcome surrogates. [J].
Redfern, RO ;
Kundel, HL ;
Seshadri, SB ;
Langlotz, C ;
Horii, SC ;
Nodine, C ;
Lanken, PN ;
Polansky, M ;
Brikman, I ;
Bozzo, M .
PACS DESIGN AND EVALUATION: ENGINEERING AND CLINICAL ISSUES - MEDICAL IMAGING 1997, 1997, 3035 :424-430
[10]   Impact of filmless imaging on the frequency of clinician review of radiology images [J].
Reiner, BI ;
Siegel, EL ;
Hooper, F ;
Protopapas, Z .
JOURNAL OF DIGITAL IMAGING, 1998, 11 (03) :149-150