Differences in crestal bone-to-implant contact following an under-drilling compared to an over-drilling protocol. A study in the rabbit tibia

被引:30
作者
Cohen, Omer [1 ]
Ormianer, Zeev [2 ]
Tal, Haim [1 ]
Rothamel, Daniel [4 ]
Weinreb, Miron [3 ]
Moses, Ofer [1 ]
机构
[1] Tel Aviv Univ, Maurice & Gabriela Goldschleger Sch Dent Med, Dept Periodontol & Dent Implantol, Tel Aviv, Israel
[2] Tel Aviv Univ, Sch Dent Med, Dept Oral Rehabil, Tel Aviv, Israel
[3] Tel Aviv Univ, Sch Dent Med, Dept Oral Biol, Tel Aviv, Israel
[4] Univ Cologne, Dept Oral & Maxillo Facial Plast Surg, Cologne, Germany
关键词
BIC; Insertion; Torque; Implants; Over-drilling; Under-drilling; OSTEOBLAST GENE-EXPRESSION; INSERTION TORQUE; FORMATION ADJACENT; STABILITY; DENSITY; MICROMOTION; DOGS;
D O I
10.1007/s00784-016-1765-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The objective of this study is to compare bone-to-implant contact (BIC) between implants inserted at high torque due to under-drilling of the crestal bone to those inserted at low torque due to over-drilling of the crestal bone. Forty implants with diameters of 3.75 mm (group A) or 3.55 mm (group B) were inserted in the proximal tibiae of NZW rabbits in two separate surgeries on day 0 or 21. Osteotomy of the crestal bone was finalized with a 3.65-mm drill. In group A, implants were inserted at torque ae<yen>35 Ncm (under-drilling) and in group B with torque < 10 Ncm (over-drilling). Implants and their surrounding bone were retrieved on day 42, thus creating 3- and 6-week observation periods, processed for non-decalcified histology and stained with toluidine blue. Crestal BIC (c-BIC) and total BIC (t-BIC) were measured. Wilcoxon test was used to evaluate differences between groups. Three weeks post-surgery, the mean c-BIC in group A was 16.3 +/- 3.3 vs 31.5 +/- 3.4 % in group B (P < 0.05). At 6 weeks, a similar trend was observed (group A: 28.7 +/- 3.6 %; group B: 38.4 +/- 4.9 %) (P > 0.05). No differences in t-BIC were noted at 3 weeks and at 6 weeks between the groups. Insertion of implants with an over-drilling protocol of the crestal aspect of the osteotomy resulted in increased short-term crestal bone-to-implant contact. Insertion of implants with a high torque following an under-drilling protocol, commonly used for immediate loading, may reduce crestal bone-to-implant contact at early healing stages.
引用
收藏
页码:2475 / 2480
页数:6
相关论文
共 22 条
[1]   Early bone formation adjacent to rough and turned endosseous implant surfaces - An experimental study in the dog [J].
Abrahamsson, I ;
Berglundh, T ;
Linder, E ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :381-392
[2]   Tissue characteristics at microthreaded implants: An experimental study in dogs [J].
Abrahamsson, Ingemar ;
Berglundh, Tord .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2006, 8 (03) :107-113
[3]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[4]   Implant Compression Necrosis: Current Understanding and Case Report [J].
Bashutski, Jill D. ;
D'Silva, Nisha J. ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2009, 80 (04) :700-704
[5]   De novo alveolar bone formation adjacent to endosseous implants -: A model study in the dog [J].
Berglundh, T ;
Abrahamsson, I ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (03) :251-262
[6]   Biomechanical Evaluation of Undersized Drilling on Implant Biomechanical Stability at Early Implantation Times [J].
Coelho, Paulo G. ;
Marin, Charles ;
Teixeira, Hellen S. ;
Campos, Felipe E. ;
Gomes, Julio B. ;
Guastaldi, Fernando ;
Anchieta, Rodolfo B. ;
Silveira, Lucas ;
Bonfante, Estevam A. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (02) :E69-E75
[8]   Effect of insertion torque on titanium implant osseointegration: an animal experimental study [J].
Duyck, Joke ;
Roesems, Rutger ;
Cardoso, Marcio V. ;
Ogawa, Toru ;
Camargos, Germana De Villa ;
Vandamme, Katleen .
CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (02) :191-196
[9]   The effect of static bone strain on implant stability and bone remodeling [J].
Halldin, Anders ;
Jimbo, Ryo ;
Johansson, Carina B. ;
Wennerberg, Ann ;
Jacobsson, Magnus ;
Albrektsson, Tomas ;
Hansson, Stig .
BONE, 2011, 49 (04) :783-789
[10]  
Krassas G. E., 2001, Journal of Musculoskeletal & Neuronal Interactions, V2, P143