共 23 条
Prospective Evaluation of Standalone XEN Gel Implant and Combined Phacoemulsification-XEN Gel Implant Surgery: 1-Year Results
被引:125
作者:
Mansouri, Kaweh
[1
,2
]
Guidotti, Jacopo
[1
]
Rao, Harsha L.
[3
]
Ouabas, Adel
[1
]
D'Alessandro, Elisa
[1
]
Roy, Sylvain
[1
]
Mermoud, Andre
[1
]
机构:
[1] Swiss Vis Network, Montchoisi Clin, Glaucoma Res Ctr, CH-1006 Lausanne, Switzerland
[2] Univ Colorado, Sch Med, Dept Ophthalmol, Denver, CO 80202 USA
[3] Narayana Nethralaya, Bengaluru, Karnataka, India
关键词:
glaucoma;
surgery;
XEN gel stent;
minimally invasive glaucoma surgery;
OPEN-ANGLE GLAUCOMA;
INTRAOCULAR-PRESSURE;
SURGICAL-TREATMENT;
FOLLOW-UP;
STENT;
TRABECULECTOMY;
TRIAL;
COMPLICATIONS;
MICROSTENT;
SAFETY;
D O I:
10.1097/IJG.0000000000000858
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
Purpose: To evaluate the safety and efficacy of XEN gel implant (Allergan Inc., Irvine) as a standalone versus combined XEN-Phacoemulsification surgery (XEN+cataract) in glaucoma patients. Methods: Prospective, interventional study. One-hundred forty-nine eyes (113 patients) with open-angle glaucoma and uncontrolled intraocular pressure (IOP) despite medical treatment were enrolled at a tertiary glaucoma center and followed up for a minimum of 1 year. Approximately two-thirds of patients underwent combined XEN+cataract surgery, while the remainder had XEN alone surgery. Primary outcome was a 20% or more decrease in IOP from medicated baseline at 1 year. Mean IOP, mean number of medications at last follow-up, and incidence of adverse effects were analyzed. Results: Of 149 enrolled eyes, data of 87 (58%) were available at 1 year. A total of 109 (73.2%) eyes underwent XEN+cataract surgery and 40 (26.8%) XEN alone surgery. Mean medicated IOP was 20.0 +/- 7.1 at baseline and 13.9 +/- 4.3 mm Hg at 1 year (P < 0.01), a 31% IOP reduction. Mean medications dropped from 1.9 +/- 1.3 preoperatively to 0.5 +/- 0.8 at 1 year (P < 0.001). In total, 62.1% of patients achieved a = 20% IOP reduction; this proportion was higher in the XEN alone group. 57.7% of eyes achieved complete success (without any antiglaucoma medications) and 71.1% qualified success (with or without medications) when IOP < 16 mm Hg was considered as the definition of success. In all, 37% of patients required needling intervention. Adverse effects included bleb revision in 5 eyes, choroidal detachment in 2 eyes, and second glaucoma surgery in 9 eyes. Conclusions: The XEN gel implant as a standalone procedure or combined with cataract surgery demonstrated safe and sustained IOP reduction after 1 year.
引用
收藏
页码:140 / 147
页数:8
相关论文