Analysis of perchlorate in foods and beverages by ion chromatography coupled with tandem mass spectrometry (IC-ESI-MS/MS)

被引:159
作者
El Aribi, Houssain
Le Blanc, Yves J. C.
Antonsen, Stephen
Sakuma, Takeo
机构
[1] Appl Biosyst MDS Sciex, Concord, ON L4K 4V8, Canada
[2] Dionex Canada Ltd, Oakville, ON L6J 7W5, Canada
关键词
perchlorate; produce; wine; beer; IC; ESI-MS/MS;
D O I
10.1016/j.aca.2006.03.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new IC-ESI-MS/MS method, with simple sample preparation procedure, has been developed for quantification and confirmation of perchlorate (ClO4-) anions in water, fresh and canned food, wine and beer samples at low part-per-trillion (ng l(-1)) levels. To the best of our knowledge, this is the first time an analytical method is used for determination of perchlorate in wine and beer samples. The IC-ESI-MS/MS instrumentation consisted of an ICS-2500 ion chromatography (IC) system coupled to either an API 2000 (TM) or an API 3200 (TM) mass spectrometer. The IC-ESI-MS/MS system was optimized to monitor two pairs of precursor and fragment ion transitions, i.e., multiple reaction monitoring (MRM). All samples had oxygen-18 isotope labeled perchlorate internal standard (ISTD) added prior to extraction. Chlorine isotope ratio (Cl-35/Cl-37) was used as a confirmation tool. The transition of (ClO4-)-Cl-35-O-16 (m/z 98.9) into (ClO3-)-Cl-35-O-16 (m/z 82.9) was monitored for quantifying the main analyte; the transition of (ClO4-)-Cl-37-O-16 (m/z 100.9) into (ClO3-)-Cl-37-O-16 (m/z 84.9) was monitored for examining a proper isotopic abundance ratio of Cl-35/Cl-37; and the transition of (ClO4-)-Cl-35-O-18 (m/z 107.0) into (ClO3-)-Cl-35-O-18 (m/z 89.0) was monitored for quantifying the internal standard. The minimum detection limit (MDL) for this method in de-ionized water is 5 ng l(-1) (ppt) using the API 2000 (TM) mass spectrometer and 0.5 ng l(-1) using the API 3200 (TM) mass spectrometer. Over 350 food and beverage samples were analyzed mostly in triplicate. Except for four, all samples were found to contain measurable amounts of perchlorate. The levels found ranged from 5 ng l(-1) to 463.5 +/- 6.36 mu g kg(-1) using MRM 98.9 -> 82.9 and 100 mu l injection. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 29 条
[1]  
*DION CORP, 134 DION CORP
[2]  
*DION CORP, 145 DION CORP
[3]  
*DION CORP, 148 DION CORP
[4]   Quantitative analysis of perchlorate in extracts of whole fish homogenates by ion chromatography: comparison of suppressed conductivity detection and electrospray ionization mass spectrometry [J].
Dodds, ED ;
Kennish, JM ;
von Hippel, FA ;
Bernhardt, R ;
Hines, ME .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (5-6) :881-887
[5]   Determination of perchlorate in tobacco plants and tobacco products [J].
Ellington, JJ ;
Wolfe, NL ;
Garrison, AW ;
Evans, JJ ;
Avants, JK ;
Teng, QC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (15) :3213-3218
[6]   Trace level determination of perchlorate in water matrices and human urine using ESI-FAIMS-MS [J].
Ells, B ;
Barnett, DA ;
Purves, RW ;
Guevremont, R .
JOURNAL OF ENVIRONMENTAL MONITORING, 2000, 2 (05) :393-397
[7]   Health effects assessment for environmental perchlorate contamination: The dose response for inhibition of thyroidal radioiodine uptake in humans [J].
Greer, MA ;
Goodman, G ;
Pleus, RC ;
Greer, SE .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2002, 110 (09) :927-937
[8]  
Hawley G.G., 1977, CONDENSED CHEM DICT
[9]   Perchlorate in milk [J].
Kirk, AB ;
Smith, EE ;
Tian, K ;
Anderson, TA ;
Dasgupta, PK .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (21) :4979-4981
[10]   Analysis of perchlorate in groundwater by electrospray ionization mass spectrometry/mass spectrometry [J].
Koester, CJ ;
Beller, HR ;
Halden, RU .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (09) :1862-1864