Embedded piezoelectric ceramic transducers in sandwiched beams

被引:45
作者
Annamdas, VGM [1 ]
Soh, CK [1 ]
机构
[1] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore 639798, Singapore
关键词
D O I
10.1088/0964-1726/15/2/037
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Surface bonded piezoelectric ceramic (PZT) transducers are currently the most prominent area of research in structural health monitoring using electromechanical impedance methods. This paper presents a new embedded PZT patch and its interaction with the host sandwiched beam. Durability and protection from surface finish, vandalism and the environment are important features of the embedment. The paper also demonstrates the use of thickness vibration of the PZT patch in electromechanical admittance formulations. This embedded PZT-structure interaction model is based on the new concept of 'average sum impedance'. The formulations used for this model can be conveniently employed to extract the mechanical impedance of any 'unknown' PZT patch embeddable plane structure. The mechanical impedance of the structure is obtained from the admittance signatures of the embedded PZT patch. The proposed model is experimentally verified on sandwiched beams.
引用
收藏
页码:538 / 549
页数:12
相关论文
共 26 条
[1]  
*AG TECHN, 2004, TEST MEAS CAT
[2]  
*ANSYS INC, 2000, ANSYS REF MAN REL 5
[3]   Qualitative impedance-based health monitoring of civil infrastructures [J].
Ayres, JW ;
Lalande, F ;
Chaudhry, Z ;
Rogers, CA .
SMART MATERIALS & STRUCTURES, 1998, 7 (05) :599-605
[4]  
Bathe K, 2007, Finite element procedures
[5]   Structural health monitoring by piezo-impedance transducers. I: Modeling [J].
Bhalla, S ;
Soh, CK .
JOURNAL OF AEROSPACE ENGINEERING, 2004, 17 (04) :154-165
[6]   Structural impedance based damage diagnosis by piezo-transducers [J].
Bhalla, S ;
Soh, CK .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2003, 32 (12) :1897-1916
[7]  
Doebling SW., 1998, Shock Vib. Digest, V30, P99, DOI [10.1177/058310249803000201, DOI 10.1177/058310249803000201]
[8]   Experimental investigation of E/M impedance health monitoring for spot-welded structural joints [J].
Giurgiutiu, V ;
Reynolds, A ;
Rogers, CA .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 1999, 10 (10) :802-812
[9]  
Giurgiutiu V, 2000, J INTEL MAT SYST STR, V11, P959, DOI [10.1106/AlHU-23JD-M5AU-ENGW, 10.1106/A1HU-23JD-M5AU-ENGW]
[10]  
*HEWL PACK, 4192A HP LF