Continuous depth-of-interaction measurement in a single-layer pixelated crystal array using a single-ended readout

被引:66
作者
Ito, Mikiko [1 ]
Lee, Min Sun [1 ,2 ]
Lee, Jae Sung [1 ,2 ,3 ,4 ,5 ]
机构
[1] Seoul Natl Univ, Dept Nucl Med, Seoul 110744, South Korea
[2] Seoul Natl Univ, Interdisciplinary Programs Radiat Appl Life Sci, Seoul 110744, South Korea
[3] Seoul Natl Univ, Dept Biomed Sci, Seoul 110744, South Korea
[4] Seoul Natl Univ, WCU Brain & Cognit Sci, Seoul 110744, South Korea
[5] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul 110744, South Korea
关键词
INTERACTION DETECTOR; SPATIAL-RESOLUTION; PET; PERFORMANCE; DESIGN; POSITION; LIGHT; LSO; SCINTILLATOR; BLOCK;
D O I
10.1088/0031-9155/58/5/1269
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a depth-of-interaction (DOI)-encoding method to extract continuous DOI information using a single-layer scintillation crystal array with single-ended readout for cost-effective high-resolution positron emission tomography (PET). DOI information is estimated by different light dispersions along the x-and y-directions tailored by the geometric shape of reflectors around the crystals. The detector module comprised a 22 x 22 array of unpolished LGSO crystals (2.0 x 2.0 x 20 mm(3)). A multi-anode photomultiplier tube with 64 anodes measured light dispersion in the crystal array. Gain non-uniformity of each anode was corrected by an analogue gain compensation circuit. DOI information was determined from peaks in the x and y anode-signal distributions normalized by the total energy of the distribution. Average DOI resolution (full width at half maximum, FWHM) over all crystals and depths was estimated to be 4.2 mm. Average energy resolution from the 2 to 18 mm DOI positions was 11.3% +/- 0.79%, with 13% difference in photo-peak positions. Average time resolutions (FWHM) were 320-356 ps. Energy, time and DOI resolutions were uniform over all crystal positions except at the array's edge. This DOI-PET detector shows promise for applications that require high resolution and sensitivity at low cost.
引用
收藏
页码:1269 / 1282
页数:14
相关论文
共 50 条
[1]   High precision axial coordinate readout for an axial 3-D PET detector module using a wave length shifter strip matrix [J].
Braem, A. ;
Chesi, E. ;
Joram, C. ;
Seguinot, J. ;
Weilhammer, P. ;
De Leo, R. ;
Nappi, E. ;
Lustermann, W. ;
Schinzel, D. ;
Johnson, I. ;
Renker, D. ;
Albrecht, S. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (03) :1513-1521
[2]   Study of spatial resolution and depth of interaction of APD-based PET detector modules using light sharing schemes [J].
Bruyndonckx, P ;
Léonard, S ;
Liu, JG ;
Tavernier, S ;
Szupryczynski, P ;
Fedorov, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1415-1419
[3]   Towards a continuous crystal APD-based PET detector design [J].
Bruyndonckx, Peter ;
Lemaitre, Cedric ;
Schaart, Dennis ;
Maas, Marnix ;
van der Laan, D. J. ;
Krieguer, Magalie ;
Devroede, Olivier ;
Tavernier, Stefaan .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) :182-186
[4]   COLLECTION OF SCINTILLATION LIGHT FROM SMALL BGO CRYSTALS [J].
CHERRY, SR ;
SHAO, YP ;
TORNAI, MP ;
SIEGEL, S ;
RICCI, AR ;
PHELPS, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1058-1063
[5]   Use of a neural network to exploit light division in a triangular scintillating crystal [J].
Delorme, S ;
Frei, R ;
Joseph, C ;
Loude, JF ;
Morel, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 373 (01) :111-118
[6]   INITIAL CHARACTERIZATION OF A POSITION-SENSITIVE PHOTODIODE BGO DETECTOR FOR PET [J].
DERENZO, SE ;
MOSES, WW ;
JACKSON, HG ;
TURKO, BT ;
CAHOON, JL ;
GEYER, AB ;
VULETICH, T .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1084-1089
[7]   Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depth-encoding PET detector [J].
Du, Huini ;
Yang, Yongfeng ;
Cherry, Simon R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (09) :2499-2514
[8]   Continuous depth-of-interaction encoding using phosphor-coated scintillators [J].
Du, Huini ;
Yang, Yongfeng ;
Glodo, Jarek ;
Wu, Yibao ;
Shah, Kanai ;
Cherry, Simon R. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (06) :1757-1771
[9]   Dedicated PET scanners for breast imaging [J].
Freifelder, R ;
Karp, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (12) :2463-2480
[10]   Concept verification of three-layer DOI detectors for small animal PET [J].
Hong, Seong Jong ;
Kwon, Sun Il ;
Ito, Mikiko ;
Lee, Geon Song ;
Sim, Kwang-Souk ;
Park, Kwang Suk ;
Rhee, June Tak ;
Lee, Jae Sung .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) :912-917