Relation between mixed venous oxygen saturation and cerebral oxygen saturation measured by absolute and relative near-infrared spectroscopy during off-pump coronary artery bypass grafting

被引:51
作者
Moerman, A. [1 ]
Vandenplas, G. [2 ]
Bove, T. [2 ]
Wouters, P. F. [1 ]
De Hert, S. G. [1 ]
机构
[1] Ghent Univ Hosp, Dept Anesthesiol, B-9000 Ghent, Belgium
[2] Ghent Univ Hosp, Dept Cardiac Surg, B-9000 Ghent, Belgium
关键词
coronary artery bypass; off-pump; monitoring; intraoperative; oximetry; pulmonary artery catheterization; spectroscopy; near-infrared; CARDIAC-SURGERY PATIENTS; CARDIOPULMONARY BYPASS; OXIMETRY;
D O I
10.1093/bja/aes375
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. We hypothesized that previously reported contradictory results regarding the equivalence of mixed venous (Smv(O2)) and cerebral (rS(c)O(2)) oxygen saturation might be related to time delay issues and to measurement technology. In order to explore these two factors, we designed a prospective clinical study comparing Smv(O2) with relative (INVOS (R)) and absolute (Foresight (R)) rS(c)O(2) measurements. Methods. Forty-two consenting patients undergoing elective off-pump coronary artery bypass grafting were included. Two INVOS and two Foresight sensors continuously registered rS(c)O(2). Smv(O2) was measured continuously via a pulmonary artery catheter. Data were assessed by within-and between-group comparisons and correlation analysis. Results. A similar time delay of 19 (4) and 18 (4) s was found for Smv(O2) compared with rS(c)O(2) measurements by Foresight and INVOS, respectively, during haemodynamic changes. After adjusting for this time delay, the correlation between SmvO(2) and rS(c)O(2) increased from r=0.25 to 0.75 (P<0.001) for Foresight, and from r=0.28 to 0.73 (P<0.001) for INVOS. Comparison of Foresight and INVOS revealed significant differences in absolute rS(c)O(2) values (range 58-89% for Foresight and 28-95% for INVOS). Changes in rS(c)O(2) in response to acute haemodynamic alterations were significantly more pronounced with INVOS compared with Foresight (P<0.001). Conclusions. Considering the important time delay with Smv(O2), rS(c)O(2) seems to reflect more appropriately acute haemodynamic alterations. This might suggest its use as a valid alternative to invasive monitoring of tissue oxygen saturation. Relative and absolute rS(c)O(2) measurements demonstrated significant differences in measured rS(c)O(2) values and in the magnitude of rS(c)O(2) changes during haemodynamic alterations.
引用
收藏
页码:258 / 265
页数:8
相关论文
共 20 条
[1]   Correlation between cerebral and mixed venous oxygen saturation during moderate versus tepid hypothermic hemodiluted cardiopulmonary bypass [J].
Baraka, Anis ;
Naufal, Maud ;
El-Khatib, Mohamad .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 20 (06) :819-825
[2]   Noninvasive cerebral oximeter as a surrogate for mixed venous saturation in children [J].
Bhutta, Adnan T. ;
Ford, Jesse W. ;
Parker, James G. ;
Prodhan, Parthak ;
Fontenot, Eudice E. ;
Seib, Paul M. ;
Stroope, Brittany I. ;
Frazier, Elizabeth A. ;
Schmitz, Michael L. ;
Drummond-Webb, Jonathan J. ;
Morrow, William R. .
PEDIATRIC CARDIOLOGY, 2007, 28 (01) :34-41
[3]   Cerebral saturations trend with mixed venous saturations in patients undergoing extracorporeal life support [J].
Cua, CL ;
Hoffman, TM ;
Taeed, R ;
Weinstein, S ;
Gomez, D ;
Olshove, VF ;
Craenen, JM .
PERFUSION-UK, 2004, 19 (03) :171-176
[4]   Impact of Extracranial Contamination on Regional Cerebral Oxygen Saturation A Comparison of Three Cerebral Oximetty Technologies [J].
Davie, Sophie N. ;
Grocott, Hilary P. .
ANESTHESIOLOGY, 2012, 116 (04) :834-840
[5]   Cerebral near-infrared spectroscopy in adult patients after cardiac surgery is not useful for monitoring absolute values but may reflect trends in venous oxygenation under clinical conditions [J].
Dullenkopf, Alexander ;
Baulig, Werner ;
Weiss, Markus ;
Schmid, Edith R. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (04) :535-539
[6]  
Fischer GW, 2010, HEART LUNG VESSEL, V2, P249
[7]   Significant decrease of cerebral oxygen saturation during single-lung ventilation measured using absolute oximetry [J].
Hemmerling, T. M. ;
Bluteau, M. C. ;
Kazan, R. ;
Bracco, D. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (06) :870-875
[8]   MIXED VENOUS OXYGEN-SATURATION DURING CARDIOPULMONARY BYPASS POORLY PREDICTS REGIONAL VENOUS SATURATION [J].
MCDANIEL, LB ;
ZWISCHENBERGER, JB ;
VERTREES, RA ;
NUTT, L ;
UCHIDA, T ;
NGUYEN, T ;
KRAMER, GC .
ANESTHESIA AND ANALGESIA, 1995, 80 (03) :466-472
[9]  
Moerman A, 2010, ACTA ANAESTH BELG, V61, P185
[10]   Monitoring brain oxygen saturation during coronary bypass surgery: A randomized, prospective study [J].
Murkin, John M. ;
Adams, Sandra J. ;
Novick, Richard J. ;
Quantz, Mackenzie ;
Bainbridge, Daniel ;
Iglesias, Ivan ;
Cleland, Andrew ;
Schaefer, Betsy ;
Irwin, Beverly ;
Fox, Stephanie .
ANESTHESIA AND ANALGESIA, 2007, 104 (01) :51-58