Simultaneous noncontrast angiography and intraPlaque hemorrhage (SNAP) imaging for carotid atherosclerotic disease evaluation

被引:121
作者
Wang, Jinnan [1 ]
Boernert, Peter [2 ]
Zhao, Huilin [3 ]
Hippe, Daniel S. [4 ]
Zhao, Xihai [5 ]
Balu, Niranjan [4 ]
Ferguson, Marina S. [4 ]
Hatsukami, Thomas S. [6 ]
Xu, Jianrong [3 ]
Yuan, Chun [4 ,5 ]
Kerwin, William S. [4 ]
机构
[1] Philips Res N Amer, Clin Sites Res Program, Briarcliff Manor, NY USA
[2] Philips Res Europe, Tomog Imaging Syst, Hamburg, Germany
[3] Shanghai Jiao Tong Univ, Renji Hosp, Shanghai 200030, Peoples R China
[4] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[5] Tsinghua Univ, Dept Biomed Engn, Beijing 100084, Peoples R China
[6] Univ Washington, Dept Surg, Seattle, WA 98195 USA
关键词
MR angiography; intraplaque hemorrhage; SNAP; vessel wall; MAGNETIC-RESONANCE ANGIOGRAPHY; SENSITIVE INVERSION-RECOVERY; MR-ANGIOGRAPHY; PLAQUE; FLOW; SEQUENCE; EVENTS; ARTERY; ENDARTERECTOMY; ASSOCIATION;
D O I
10.1002/mrm.24254
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A simultaneous noncontrast angiography and intraplaque hemorrhage (SNAP) MR imaging technique is proposed to detect both luminal stenosis and hemorrhage in atherosclerosis patients in a single scan. Thirteen patients with diagnosed carotid atherosclerotic plaque were admitted after informed consent. All scans were performed on a 3T MR imaging system with SNAP, 2D time-of-flight and magnetization-prepared 3D rapid acquisition gradient echo sequences. The SNAP sequence utilized a phase sensitive acquisition, and was designed to provide positive signals corresponding to intraplaque hemorrhage and negative signals corresponding to lumen. SNAP images were compared to time-of-flight images to evaluate lumen size measurements using linear mixed models and the intraclass correlation coefficient. Intraplaque hemorrhage identification accuracy was evaluated by comparing to magnetization-prepared 3D rapid acquisition gradient echo images using Cohen's Kappa. Diagnostic quality SNAP images were generated from all subjects. Quantitatively, the lumen size measurements by SNAP were strongly correlated (intraclass correlation coefficient = 0.96, P < 0.001) with those measured by time-of-flight. For intraplaque hemorrhage detection, strong agreement (kappa = 0.82, P < 0.001) was also identified between SNAP and magnetization-prepared 3D rapid acquisition gradient echo images. In conclusion, a SNAP imaging technique was proposed and shows great promise for imaging both lumen size and carotid intraplaque hemorrhage with a single scan. Magn Reson Med, 2013. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:337 / 345
页数:9
相关论文
共 34 条
[1]   Detection of intraplaque hemorrhage by magnetic resonance imaging in symptomatic patients with mild to moderate carotid stenosis predicts recurrent neurological events [J].
Altaf, Nishath ;
Daniels, Lucy ;
Morgan, Paul S. ;
Auer, Dorothee ;
MacSweeney, Shane T. ;
Moody, Alan R. ;
Gladman, John R. .
JOURNAL OF VASCULAR SURGERY, 2008, 47 (02) :337-342
[2]   On the Overestimation of Early Wall Thickening at the Carotid Bulb by Black Blood MRI, With Implications for Coronary and Vulnerable Plaque Imaging [J].
Antiga, L. ;
Wasserman, B. A. ;
Steinman, D. A. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (05) :1020-1028
[3]   Improvements in Carotid Plaque Imaging Using a New Eight-Element Phased Array Coil at 3T [J].
Balu, Niranjan ;
Yarnykh, Vasily L. ;
Scholnick, Joshua ;
Chu, Baocheng ;
Yuan, Chun ;
Hayes, Cecil .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) :1209-1214
[4]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[5]   Three-dimensional flow-independent peripheral angiography [J].
Brittain, JH ;
Olcott, EW ;
Szuba, A ;
Gold, GE ;
Wright, GA ;
Irarrazaval, P ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :343-354
[6]  
Brockwell P. J., 2002, SPRINGER TEXTS STAT
[7]   Hemorrhage in the atherosclerotic carotid plaque: A high-resolution MRI study [J].
Chu, BC ;
Kampschulte, A ;
Ferguson, MS ;
Kerwin, WS ;
Yarnykh, VL ;
O'Brien, KD ;
Polissar, NL ;
Hatsukami, TS ;
Yuan, C .
STROKE, 2004, 35 (05) :1079-1084
[8]  
Davidson A., 1997, BOOTSTRAP METHODS TH
[9]  
Diggle P., 2002, ANAL LONGITUDINAL DA
[10]   3D Noncontrast MR Angiography of the Distal Lower Extremities Using Flow-Sensitive Dephasing (FSD)-Prepared Balanced SSFP [J].
Fan, Zhaoyang ;
Sheehan, John ;
Bi, Xiaoming ;
Liu, Xin ;
Carr, James ;
Li, Debiao .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (06) :1523-1532