3D Cone-Beam Rebinning and Reconstruction for Animal PET Transmission Tomography

被引:0
作者
Deng, Junjun [1 ]
Siegel, Stefan [1 ]
Chen, Mu [1 ]
机构
[1] Siemens Med Solut USA Inc, Mol Imaging Preclin Solut, Knoxville, TN 37932 USA
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
关键词
ATTENUATION CORRECTION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In PET scanners, one or multiple collimated point sources are used to acquire transmission measurements to generate attenuation maps for emission tomography [1]. The transmission acquisition is, intrinsically, 3D cone beam geometry. The acquired list-mode data are transformed into sinograms in the histogram process. Thereafter, transmission images are reconstructed from the sinograms, which are then re-projected to generate an attenuation map. Conventionally, a 2D rebinning method is used to transform the list-mode data into 2D parallel beam sinograms [2], and, accordingly, 2D reconstruction algorithms are employed to generate transmission images. Due to the inaccuracy of the 2D rebinning method, only limited oblique Lines of Response (LOR) can be used, causing limited axial coverage. If more oblique LORs were to be accepted in the rebinning process, artifacts would be introduced in the transmission images that may result in inaccurate attenuation correction factors. To address this issue, a 3D cone-beam rebinning process is proposed to faithfully transform the list-mode data, and the associated reconstruction algorithms for cone-beam geometry have been adopted to generate the transmission images. The experimental results showed the new method produced better images, especially in the axial direction.
引用
收藏
页码:2885 / 2888
页数:4
相关论文
共 6 条
[1]   Attenuation correction for small animal PET tomographs [J].
Chow, PL ;
Rannou, FR ;
Chatziioannou, AF .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08) :1837-1850
[2]  
Daube-Whitherspoon M. E., 2003, NUCL SCI S IEEE, V4, P2839
[3]   ATTENUATION CORRECTION IN PET USING SINGLE-PHOTON TRANSMISSION MEASUREMENT [J].
DEKEMP, RA ;
NAHMIAS, C .
MEDICAL PHYSICS, 1994, 21 (06) :771-778
[4]   Ordered subsets algorithms for transmission tomography [J].
Erdogan, H ;
Fessler, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :2835-2851
[5]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[6]   SINGLES TRANSMISSION IN VOLUME-IMAGING PET WITH A CS-137 SOURCE [J].
KARP, JS ;
MUEHLLEHNER, G ;
QU, H ;
YAN, XH .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) :929-944