Benefits of solvent concentration pulses in retention time modelling of liquid chromatography

被引:8
作者
Navarro-Huerta, J. A. [1 ]
Gisbert-Alonso, A. [1 ]
Torres-Lapasio, J. R. [1 ]
Garcia-Alvarez-Coque, M. C. [1 ]
机构
[1] Univ Valencia, Fac Chem, Dept Analyt Chem, C Dr Moliner 50, E-46100 Burjassot, Spain
关键词
HPLC; Isocratic elution; Gradient elution; Transient solvent increases; Experimental designs; Prediction of retention; GRADIENT ELUTION; OPTIMIZATION; SELECTIVITY; EQUATIONS; LIMITS;
D O I
10.1016/j.chroma.2019.03.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The advantages and disadvantages of the use of isocratic experimental designs including transient increments of organic solvent (i.e., pulses) in the mobile phase(s) of lowest elution strength are explored with modelling purposes. For retained solutes, this type of mixed design offers similar or better predictive capability than gradient designs, shorter measurement time than pure isocratic designs, and retention model parameters that agree with those derived from pure isocratic experiments, with similar uncertainties. The predicted retention times are comparable to those offered by models adjusted from pure isocratic designs, and the solvent waste is appreciably lower. Under a practical standpoint, mixed designs including pulse(s) can be easily constructed by replacing the slowest isocratic runs with runs containing a pulse of short duration at an intermediate time. This allows the elution of the fastest solutes with appreciable retention in the initial sector of the elution program, previous to the pulse, and the elution of the slow solutes after the pulse, also in acceptable times. The fitting of the retention data obtained with pulses is simpler compared to gradient elution, and involves solving the integral equation of gradient elution, simplified by the presence of isocratic sectors. Experiments involving pulses reveal the existence of discrepancies in the predictions for solutes eluting in the nearby of the pulse, offered by the fundamental equation of gradient elution when this is solved using numerical integration. The correction of such discrepancies implies the inclusion of intra-column delays, in the arrival of changes in the concentration of organic modifier in the gradient to the instantaneous position of the solute, along the whole migration. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:76 / 88
页数:13
相关论文
共 50 条
[41]   A principal component analysis approach for developing retention models in liquid chromatography [J].
Nikitas, P. ;
Pappa-Louisi, A. ;
Tsoumachides, S. ;
Jouyban, A. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1251 :134-140
[42]   The effect of particle and ligand types on retention and peak shape in liquid chromatography [J].
Kadlecova, Zuzana ;
Kalikova, Kveta ;
Ansorge, Martin ;
Gilar, Martin ;
Tesarova, Eva .
MICROCHEMICAL JOURNAL, 2020, 159
[43]   Retention prediction of a set of amino acids under gradient elution conditions in hydrophilic interaction liquid chromatography [J].
Gika, Helen ;
Theodoridis, Georgios ;
Mattivi, Fulvio ;
Vrhovsek, Urska ;
Pappa-Louisi, Adriani .
JOURNAL OF SEPARATION SCIENCE, 2012, 35 (03) :376-383
[44]   The impact of sampling time on peak capacity and analysis speed in on-line comprehensive two-dimensional liquid chromatography [J].
Potts, Lawrence W. ;
Stoll, Dwight R. ;
Li, Xiaoping ;
Carr, Peter W. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (36) :5700-5709
[45]   Possibilities of retention prediction in fast gradient liquid chromatography. Part 3: Short silica monolithic columns [J].
Jandera, Pavel ;
Hajek, Tomas .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1410 :76-89
[46]   Simultaneous optimization of the analysis time and the concentration detectability in open-tubular liquid chromatography [J].
Desmet, G ;
Baron, GV .
JOURNAL OF CHROMATOGRAPHY A, 2000, 867 (1-2) :23-43
[47]   Modulation of retention and selectivity in oil-in-water microemulsion liquid chromatography: A review [J].
Pankajkumar-Patel, N. ;
Peris-Garcia, E. ;
Ruiz-Angel, M. J. ;
Carda-Broch, S. ;
Garcia-Alvarez-Coque, M. C. .
JOURNAL OF CHROMATOGRAPHY A, 2019, 1592 :91-100
[48]   Accuracy of retention model parameters obtained from retention data in liquid chromatography [J].
Brau, Tyler ;
Pirok, Bob ;
Rutan, Sarah ;
Stoll, Dwight .
JOURNAL OF SEPARATION SCIENCE, 2022, 45 (17) :3241-3255
[49]   Optimum solvent selectivity and gradient mode for deoxyribonucleosides in reversed-phase high-performance liquid chromatography [J].
Lee, CH ;
Lee, JW ;
Row, KH .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :337-344
[50]   Study on the retention equation in hydrophilic interaction liquid chromatography [J].
Jin, Gaowa ;
Guo, Zhimou ;
Zhang, Feifang ;
Xue, Xingya ;
Jin, Yu ;
Liang, Xinmiao .
TALANTA, 2008, 76 (03) :522-527