Development of the relationship between odor intensity and threshold dilution ratio for swine units

被引:9
|
作者
Chen, YC
Bundy, DS
Hoff, SJ
机构
[1] N Carolina Dept Environm & Nat Resources, Div Air Qual, Fayetteville Reg Off, Fayetteville, NC 28301 USA
[2] Iowa State Univ, Dept Agr & Biosyst Engn, Ames, IA USA
来源
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION | 1999年 / 49卷 / 09期
关键词
D O I
10.1080/10473289.1999.10463882
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The following models of odor intensity for swine units were evaluated: the Weber-Fechner law model, the power law model, the Stevens model, and the Beidler model. Data were collected from four swine rooms (farrowing, finisher, gestation, and nursery) and odor threshold dilution ratios were measured by a panel using a dynamic forced-choice olfactometer. Odor intensity scales were determined by eight panelists using a six-point category scale method. A nonlinear parameter estimation method was used to estimate the parameters in each of the models. The widely used Weber-Fechner law did not adequately fit the data of odor intensity and threshold. Both the power law and the Beidler models described the data effectively, but the Beidler model showed the best fit of the data and was used as the model to represent the relationship between odor intensity and threshold dilution ratio for swine buildings.
引用
收藏
页码:1082 / 1088
页数:7
相关论文
共 50 条
  • [1] Using olfactometry to measure intensity and threshold dilution ratio for evaluating swine odor
    Chen, YC
    Bundy, DS
    Hoff, SJ
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (07): : 847 - 853
  • [2] Modeling odor intensity for swine units
    Bundy, DS
    Chen, YC
    Hoff, SJ
    Zhu, J
    AMMONIA AND ODOUR EMISSIONS FROM ANIMAL PRODUCTION FACILITIES, PROCEEDINGS, VOLS 1 AND 2, 1997, : 83 - 91
  • [3] Modeling the relationship between detection threshold and intensity of swine odors
    Nicolai, RE
    Clanton, CJ
    Guo, H
    AIR POLLUTION FROM AGRICULTURAL OPERATIONS, PROCEEDINGS, 2000, : 296 - 304
  • [4] Evaluation of indoor air quality by odor units (odor threshold ratio)
    Seto, Hiroshi
    Saitou, Ikue
    Onuki, Aya
    Todaka, Emiko
    Nakaoka, Hiroko
    Hanazato, Masamichi
    Mori, Chisato
    TOXICOLOGY LETTERS, 2009, 189 : S204 - S204
  • [5] A study on the relationship between odor hedonic ratings and individual odor detection threshold
    Charlotte Bontempi
    Laurence Jacquot
    Gérard Brand
    Scientific Reports, 12
  • [6] A study on the relationship between odor hedonic ratings and individual odor detection threshold
    Bontempi, Charlotte
    Jacquot, Laurence
    Brand, Gerard
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [7] Relationship between the cavitation threshold and maximum sonoluminescence intensity
    N. V. Dezhkunov
    Technical Physics Letters, 2008, 34
  • [8] Relationship between the cavitation threshold and maximum sonoluminescence intensity
    Dezhkunov, N. V.
    TECHNICAL PHYSICS LETTERS, 2008, 34 (04) : 346 - 349
  • [9] The study of the relationship between the slenderness ratio of fillers and the percolation threshold
    Xia, Yan-Ping
    Tao, Yu
    Zhang, Guo-Qing
    Wu, Xi-Jun
    Su, Hao
    Liang, Ping-Hui
    Wu, Hai-Ping
    Tao, Guo-Liang
    Gongneng Cailiao/Journal of Functional Materials, 2010, 41 (SUPPL. 2): : 357 - 360
  • [10] Characterization of odor released during handling of swine slurry: Part I. Relationship between odorants and perceived odor concentrations
    Blanes-Vidal, V.
    Hansen, M. N.
    Adamsen, A. P. S.
    Feilberg, A.
    Petersen, S. O.
    Jensen, B. B.
    ATMOSPHERIC ENVIRONMENT, 2009, 43 (18) : 2997 - 3005