Determination of gentamicin sulfate and related compounds by high-performance liquid chromatography with evaporative light scattering detection

被引:83
作者
Clarot, I
Chaimbault, P
Hasdenteufel, F
Netter, P
Nicolas, A
机构
[1] Univ Nancy 1, Fac Pharm, Chim Analyt Lab, CNRS,UMR 7561,UHP, F-54000 Nancy, France
[2] Univ Orleans, CNRS, Inst Chim Organ & Analyt, UMR 6005, F-45067 Orleans 2, France
[3] Fac Med, UHP, CNRS, UMR 7561, F-54500 Vandoeuvre Les Nancy, France
关键词
gentamicin sulfate; aminoglycosides; antibiotics; glycosides;
D O I
10.1016/j.chroma.2003.12.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and simple method for the separation and quantitation of gentamicin sulfate by HPLC coupled with evaporative light scattering detection (ELSD) has been developed. Detection of the different components of gentamicin is problematic because of the lack of UV absorbing chromophore. The use of the universal ELSD avoids the need for sample derivatization or use of specific detector such as pulsed amperometry. Separation was performed on a highpurity C-18 125 mm x 4 mm i.d., 3 mum, reversed phase column with 48.5 mM trifluoroacetic acid-methanol (97:3, v/v), as mobile phase at a flow rate of 0.7 ml/min. The influence of the gas nature, gas pressure and temperature of the drift tube of the detector on the detection response was investigated. Optimization was performed with the help of a specific experimental design software. This method allows the determination of the composition in components C1, C1a, C2, C2a and C2b of gentamicin sulfate samples. Mass spectrometry was employed to confirm the ELSD chromatographic profile. The method was validated using methodology described by the International Conference of Harmonization in the field of Medicinal Substances. Commercial samples of different sources were analyzed and results were in good agreement with specifications of both European and United States Pharmacopoeia. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:281 / 287
页数:7
相关论文
共 34 条
[1]   Analysis of gentamicin by liquid chromatography with pulsed electrochemical detection [J].
Adams, E ;
Roelants, W ;
De Paepe, R ;
Roets, E ;
Hoogmartens, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) :689-698
[2]   A COMPARISON OF THE HOMOGENEOUS ENZYME-IMMUNOASSAY AND POLARIZATION FLUOROIMMUNOASSAY OF GENTAMICIN [J].
ANDREWS, JM ;
WISE, R .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1984, 14 (05) :509-520
[3]   ASSAY OF GENTAMICIN IN SERUM BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
ANHALT, JP .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1977, 11 (04) :651-655
[4]  
ASMUS PA, 1984, J CHROMATOGR, V316, P461
[5]  
BREDY J, 1977, J ANTIBIOT, V30, P945
[6]  
Cherlet M, 2000, J MASS SPECTROM, V35, P1342, DOI 10.1002/1096-9888(200011)35:11<1342::AID-JMS71>3.0.CO
[7]  
2-Y
[8]  
Dreux M., 1996, LC GC INTERNATIONAL, V9, P148
[9]  
DREUX M, 1990, SPECTRA 2000, V151, P16
[10]  
*EUR DEP QUAL MED, 2003, MON EUR DEP QUAL MED