Venous blood effects in spin-echo fMRI of human brain

被引:0
|
作者
Oja, JME
Gillen, J
Kauppinen, RA
Kraut, M
van Zijl, PCM
机构
[1] Univ Kuopio, AI Virtanen Inst Mol Sci, NMR Res Grp, FIN-70211 Kuopio, Finland
[2] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
关键词
functional MRI; spin echo; blood oxygenation level-dependent; brain; visual cortex; venous blood;
D O I
10.1002/(SICI)1522-2594(199910)42:4<617::AID-MRM1>3.0.CO;2-Q
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The spin-echo response to visual activation was studied as a function of spatial resolution at a field of 1.5 T. The results showed that the increase in absolute T-2 upon activation was as large as 22.8 +/- 3.1% (P < 0.05) at the highest resolution (5.3 mm(3)), while it was as small as 3.5 +/- 0.2% (P < 0.05) at the lowest resolution (42.2 mm(3)). In addition, upon increasing resolution, the spin-echo signal decay as a function of echo time changed from monoexponential to nonexponential. These data indicate that, when using the standard resolution for fMRI studies at 1.5 T,the effects of spin-echo changes in the draining veins are of major contribution to the total blood oxygenation level-dependent (BOLD) signal changes measured in voxels encompassing the activated brain areas. The data can be quantitatively accounted for using a model based on the intravascular origin of the spin-echo effect including both macrovascular and microvascular effects. Existing theories for the spin-echo BOLD effect based on diffusion through field gradients predict negligible spin-echo effects inside the large vessels and are therefore incompatible with the data. Magn Reson Med 42:617-626, 1999. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:617 / 626
页数:10
相关论文
共 50 条
  • [41] SPIN-ECHO IN VARIABLE SEMICONDUCTORS
    VOLKOV, AS
    LIPKO, AL
    MERETLIEV, SM
    TSARENKOV, BV
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1986, 50 (02): : 294 - 296
  • [42] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [43] SPIN-ECHO MODULATION IN RUBY
    LIAO, PF
    HARTMANN, SR
    SOLID STATE COMMUNICATIONS, 1972, 10 (11) : 1089 - &
  • [44] SPIN-ECHO SPECTROMETER FOR FERRIMAGNETICS
    KUNEVICH, AV
    LAVRENTEV, GV
    LATYSHEV, MA
    PAVLOV, GD
    FILIPPOV, VV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1984, 27 (02) : 391 - 394
  • [45] The Spin-Echo System Reconsidered
    D. A. Lavis
    Foundations of Physics, 2004, 34 : 669 - 688
  • [46] SPIN-ECHO SPECTROMETER FOR FERROMAGNETS
    USTINOV, VB
    RASSVETA.LA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1969, (01): : 115 - +
  • [47] Simultaneous spin-echo refocusing
    Günther, M
    Feinberg, DA
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) : 513 - 523
  • [48] SPIN-ECHO NEUTRON SPECTROSCOPY
    ROBINSON, AL
    SCIENCE, 1981, 213 (4512) : 1098 - 1098
  • [49] SIMPLE, SPIN-ECHO SPECTROMETER
    MULLER, BH
    NOBLE, JD
    BURNETT, LJ
    HARMON, JF
    MCKAY, DR
    AMERICAN JOURNAL OF PHYSICS, 1974, 42 (01) : 58 - 64
  • [50] SPIN-ECHO DEFOCUSING SPECTROSCOPY
    MACHOWSKA, E
    NADOLSKI, S
    ACTA PHYSICA POLONICA A, 1989, 76 (02) : 207 - 212