Venous blood effects in spin-echo fMRI of human brain

被引:0
|
作者
Oja, JME
Gillen, J
Kauppinen, RA
Kraut, M
van Zijl, PCM
机构
[1] Univ Kuopio, AI Virtanen Inst Mol Sci, NMR Res Grp, FIN-70211 Kuopio, Finland
[2] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
关键词
functional MRI; spin echo; blood oxygenation level-dependent; brain; visual cortex; venous blood;
D O I
10.1002/(SICI)1522-2594(199910)42:4<617::AID-MRM1>3.0.CO;2-Q
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The spin-echo response to visual activation was studied as a function of spatial resolution at a field of 1.5 T. The results showed that the increase in absolute T-2 upon activation was as large as 22.8 +/- 3.1% (P < 0.05) at the highest resolution (5.3 mm(3)), while it was as small as 3.5 +/- 0.2% (P < 0.05) at the lowest resolution (42.2 mm(3)). In addition, upon increasing resolution, the spin-echo signal decay as a function of echo time changed from monoexponential to nonexponential. These data indicate that, when using the standard resolution for fMRI studies at 1.5 T,the effects of spin-echo changes in the draining veins are of major contribution to the total blood oxygenation level-dependent (BOLD) signal changes measured in voxels encompassing the activated brain areas. The data can be quantitatively accounted for using a model based on the intravascular origin of the spin-echo effect including both macrovascular and microvascular effects. Existing theories for the spin-echo BOLD effect based on diffusion through field gradients predict negligible spin-echo effects inside the large vessels and are therefore incompatible with the data. Magn Reson Med 42:617-626, 1999. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:617 / 626
页数:10
相关论文
共 50 条
  • [31] Dependence of gradient-echo and spin-echo BOLD fMRI at 4T on diffusion weighting
    Michelich, Charles R.
    Song, Allen W.
    MacFall, James R.
    NMR IN BIOMEDICINE, 2006, 19 (05) : 566 - 572
  • [32] Comparison of spin-echo MR pulse sequences for imaging of the brain
    Fellner, F
    Fellner, C
    Held, P
    Schmitt, R
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (09) : 1617 - 1625
  • [33] Gradient- and spin-echo MR imaging of the brain - Reply
    Melhem, ER
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (07) : 1382 - 1383
  • [34] A prospective comparison of brain contrast characteristics and lesion detection using single-shot fast spin-echo and fast spin-echo
    Mittal, TK
    Halpin, SFS
    Bourne, MW
    Hourihan, MD
    Perkins, T
    Sun, Y
    Tan, S
    NEURORADIOLOGY, 1999, 41 (07) : 480 - 486
  • [35] Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Accardi, M
    Pappalardo, S
    Sarno, C
    DeMaria, M
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 233 - 235
  • [36] MR OF THE HEAD AND NECK - COMPARISON OF FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO SEQUENCES
    FULBRIGHT, R
    PANUSH, D
    SZE, G
    SMITH, RC
    CONSTABLE, RT
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (04) : 767 - 773
  • [37] Reduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 Tesla
    Wang, JJ
    Li, L
    Roc, AC
    Alsop, DC
    Tang, K
    Butler, NS
    Schnall, MD
    Detre, JA
    MAGNETIC RESONANCE IMAGING, 2004, 22 (01) : 1 - 7
  • [38] A prospective comparison of brain contrast characteristics and lesion detection using single-shot fast spin-echo and fast spin-echo
    T. K. Mittal
    S. F. S. Halpin
    M. W. Bourne
    M. D. Hourihan
    T. Perkins
    Y. Sun
    S. Tan
    Neuroradiology, 1999, 41 : 480 - 486
  • [39] T 2 relaxometry measurements in low spatial frequency brain regions differ between fast spin-echo and multiple-echo spin-echo sequences
    Rajagopalan, Venkateswaran
    Lowe, Mark J.
    Beall, Erik B.
    Yue, Guang H.
    Pioro, Erik P.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2013, 26 (05) : 443 - 450
  • [40] Diffusion dispersion imaging: Mapping oscillating gradient spin-echo frequency dependence in the human brain
    Arbabi, Aidin
    Kai, Jason
    Khan, Ali R.
    Baron, Corey A.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (06) : 2197 - 2208