Application of high-performance liquid chromatography with charged aerosol detection for universal quantitation of undeclared phosphodiesterase-5 inhibitors in herbal dietary supplements

被引:28
作者
Poplawska, Magdalena [1 ,2 ]
Blazewicz, Agata [1 ]
Bukowinska, Kinga [2 ]
Fijalek, Zbigniew [1 ,2 ]
机构
[1] Natl Med Inst, Dept Pharmaceut Chem, PL-00725 Warsaw, Poland
[2] Med Univ Warsaw, Dept Bioanal & Drug Anal, PL-02097 Warsaw, Poland
关键词
Charged aerosol detector; Universal calibration; PDE-5; inhibitor; Adulteration; Counterfeit dietary supplement; TANDEM MASS-SPECTROMETRY; EVAPORATIVE LIGHT-SCATTERING; LC-ESI-MS; SILDENAFIL; VARDENAFIL; QUANTIFICATION; IMPURITIES; UV; IDENTIFICATION; ADULTERANTS;
D O I
10.1016/j.jpba.2013.06.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Incidents of detecting novel analogues of phosphodiesterase 5 (PDE-5) inhibitors in illicit dietary supplements for erectile dysfunction are constantly reported. However, little is known about their content in a single dose, mainly due to the poor availability or inaccessibility of pure reference standards. This study presents a new strategy of quantitative analysis of unknown and recently identified compounds. Charged aerosol detector (CAD), described as "universal detector", combined with high-performance liquid chromatography (HPLC) system proved to be a useful tool for fast and simple quantitation of PDE-5 inhibitors' analogues in a complex herbal matrix without individual reference standards available:Universal calibration was employed for calculations. Two easily obtainable reference materials - sildenafil and tadalafil - were selected as universal standards and the content of analogues was estimated with respect to their response. The error of proposed indirect determination was found to be +/- 3%, which is less than enough to obtain a reliable result of the content. The elaborated method was applied for quantitative analyses of PDE-5 inhibitors and 10 analogues detected in 22 illicit dietary supplements and two bulk powdered herbal materials. All target analogues were identified using time-of-flight mass spectrometry with electrospray ionization. Obtained results indicate that the quantity of PDE-5 inhibitors in all tested samples is considered to be pharmacologically relevant. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 243
页数:12
相关论文
共 50 条
  • [21] Simultaneous Quantitation of 13 Active Components in SimiaoYong'an Decoction Using High-Performance Liquid Chromatography with Diode Array Detection
    Zheng, Liang
    Wang, Mengyue
    Chen, Zhong
    Hou, Jincai
    Li, Xiaobo
    ACTA CHROMATOGRAPHICA, 2019, 31 (03) : 216 - 221
  • [22] Determination of Inulin-type Fructooligosaccharides in Edible Plants by High-Performance Liquid Chromatography with Charged Aerosol Detector
    Li, Jing
    Hu, Dejun
    Zong, Wanrong
    Lv, Guangping
    Zhao, Jing
    Li, Shaoping
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2014, 62 (31) : 7707 - 7713
  • [23] Simultaneous Analysis of Sexual Stimulants and Anabolic Steroids as Adulterants in Dietary Supplements by High Performance Liquid Chromatography with Photodiode Array Detection
    Viana, Carine
    Marcon, Gabriela Zanella
    Dal Molin, Thais Ramos
    Bohrer, Denise
    do Nascimento, Paulo Cicero
    de Carvalho, Leandro M.
    CURRENT PHARMACEUTICAL ANALYSIS, 2021, 17 (06) : 767 - 773
  • [24] Development of high performance liquid chromatography methods with charged aerosol detection for the determination of lincomycin, spectinomycin and its impurities in pharmaceutical products
    Stypulkowska, K.
    Blazewicz, A.
    Brudzikowska, A.
    Warowna-Grzeskiewicz, M.
    Sarna, K.
    Fijalek, Z.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 112 : 8 - 14
  • [25] High performance liquid chromatography-charged aerosol detection applying an inverse gradient for quantification of rhamnolipid biosurfactants
    Behrens, Beate
    Baune, Matthias
    Jungkeit, Janek
    Tiso, Till
    Blank, Lars M.
    Hayen, Heiko
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1455 : 125 - 132
  • [26] Simultaneous determination of yohimbine, sildenafil, vardenafil and tadalafil in dietary supplements using high-performance liquid chromatography-tandem mass spectrometry
    Zhang, Ying
    Huang, Zhiqiang
    Ding, Li
    Yan, Hongfei
    Wang, Meiling
    Zhu, Shaohua
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (14) : 2109 - 2114
  • [27] Simultaneous Identification of 18 Illegal Adulterants in Dietary Supplements by Using High-Performance Liquid Chromatography-Mass Spectrometry
    Tagami, Takaomi
    Aoyama, Airin
    Takeda, Akihiro
    Asada, Akiko
    Doi, Takahiro
    Kajimura, Keiji
    Sawabe, Yoshiyuki
    FOOD HYGIENE AND SAFETY SCIENCE, 2014, 55 (01): : 34 - 40
  • [28] Evaluation of a low cell constant conductance detector for detection of charged species in high-performance liquid chromatography
    Suganuma, Yoshinori
    Toltl, Nick
    Dhirani, Al-Amin
    ANALYTICAL METHODS, 2013, 5 (23) : 6855 - 6863
  • [29] Chemical Profiling and Quality Evaluation of Gualou-Xiebai Herbal Pair by Liquid Chromatography-Tandem Mass Spectrometry With Feature-Based Molecular Network and High-Performance Liquid Chromatography With Charged Aerosol Detector
    Zhang, Lu
    Cai, Xujia
    Cheng, Yongzhe
    Chen, Shiyi
    Zhang, Min
    Zhang, Hongyang
    Hu, Ping
    JOURNAL OF SEPARATION SCIENCE, 2025, 48 (03)
  • [30] A non-derivative method for the quantitative analysis of isosteroidal alkaloids from Fritillaria by high performance liquid chromatography combined with charged aerosol detection
    Long, Zhen
    Guo, Zhimou
    Acworth, Ian N.
    Liu, Xiaoda
    Jin, Yan
    Liu, Xingguo
    Liu, Lvye
    Liang, Lina
    TALANTA, 2016, 151 : 239 - 244