Medical staff extremity dosimetry in CT fluoroscopy: an anthropomorphic hand voxel phantom study

被引:14
作者
Figueira, C. [1 ]
Becker, F. [2 ]
Blunck, C. [2 ]
DiMaria, S. [1 ]
Baptista, M. [1 ]
Esteves, B. [3 ]
Paulo, G. [4 ]
Santos, J. [4 ]
Teles, P. [1 ]
Vaz, P. [1 ]
机构
[1] Univ Tecn Lisboa, Inst Super Tecn, IST CTN, Unidade Proteccao & Seguranca Radiol, P-2686953 Sacavem, Portugal
[2] KIT, Inst Nucl Waste Disposal, D-76344 Eggenstein Leopoldshafen, Germany
[3] Hosp Geral, Ctr Hosp Coimbra, Dept Radiobiol, Coimbra, Portugal
[4] Escola Super Tecnol Saude Coimbra, P-3046854 Coimbra, Portugal
关键词
GUIDED INTERVENTIONAL PROCEDURES; MONTE-CARLO SIMULATIONS; RADIATION; PATIENT; VALIDATION; EXPOSURE; GUIDANCE; BIOPSY; MODELS; ORGAN;
D O I
10.1088/0031-9155/58/16/5433
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work aims to contribute to the study of the radiation dose distribution delivered to the hands of medical staff members during a general computed tomographic (CT) fluoroscopic guided procedure. In this study, both Monte Carlo simulations and measurements were performed. For free-in-air and computed tomography dose index (CTDI) body phantom measurements, a standard pencil ionization chamber (IC) 100 mm long was used. The CT scanner model was implemented using MCNPX (Monte Carlo N-Particle eXtended) and was successfully validated by comparing the simulated results with measurements. Subsequently, CT images of a hand, together with an anthropomorphic phantom, were voxelized and used with the MCNPX code for dose calculations. The hand dose distribution study was performed both by using thermo-luminescent detector measurements and Monte Carlo simulations. The validated simulation tool provides a new perspective for detailed investigations of CT-irradiation scenarios. Simulations show that there is a strong dose gradient, namely the even zones of the hand that are in precise vicinity to the x-ray beam only receive about 4% of the maximum dose delivered to adjacent areas which are directly exposed to the primary x-ray beam. Finally, the scatter contribution of the patient was also studied through MC simulations. The results show that for directly exposed parts of the hand surface, the dose is reduced by the body of the patient (due to the shielding), whereas the dose is increased by scattered radiation from the patient for parts of the skin that receive scattered radiation only.
引用
收藏
页码:5433 / 5448
页数:16
相关论文
共 31 条
[1]  
[Anonymous], 96 AAPM TASK GROUP 2
[2]   Fluoroscopically Guided Interventional Procedures: A Review of Radiation Effects on Patients' Skin and Hair [J].
Balter, Stephen ;
Hopewell, John W. ;
Miller, Donald L. ;
Wagner, Louis K. ;
Zelefsky, Michael J. .
RADIOLOGY, 2010, 254 (02) :326-341
[3]   Benefits and safety of CT fluoroscopy in interventional radiologic procedures [J].
Carlson, SK ;
Bender, CE ;
Classic, KL ;
Zink, FE ;
Quam, JP ;
Ward, EM ;
Oberg, AL .
RADIOLOGY, 2001, 219 (02) :515-520
[4]  
Cranley K, 1997, SRS78 IPEM
[5]   Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose [J].
DeMarco, J. J. ;
Cagnon, C. H. ;
Cody, D. D. ;
Stevens, D. M. ;
McCollough, C. H. ;
Zankl, M. ;
Angel, E. ;
McNitt-Gray, M. F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (09) :2583-2597
[6]   A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms [J].
DeMarco, JJ ;
Cagnon, CH ;
Cody, DD ;
Stevens, DM ;
McCollough, CH ;
O'Daniel, J ;
McNitt-Gray, MF .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (17) :3989-4004
[7]   The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations [J].
Gu, J. ;
Bednarz, B. ;
Caracappa, P. F. ;
Xu, X. G. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) :2699-2717
[8]   PRECISE BIOPSY LOCALIZATION BY COMPUTED TOMOGRAPHY [J].
HAAGA, JR ;
ALFIDI, RJ .
RADIOLOGY, 1976, 118 (03) :603-607
[9]   VOXEL2MCNP: SOFTWARE FOR HANDLING VOXEL MODELS FOR MONTE CARLO RADIATION TRANSPORT CALCULATIONS [J].
Hegenbart, Lars ;
Poelz, Stefan ;
Benzler, Andreas ;
Urban, Manfred .
HEALTH PHYSICS, 2012, 102 (02) :221-229
[10]  
Jarry G, 2002, THESIS UCLA CALIFORN