Experimental study on the air/water counter-current flow limitation in a model of the hot leg of a pressurized water reactor

被引:30
作者
Deendarlianto [1 ,2 ]
Vallee, Christophe [1 ]
Lucas, Dirk [1 ]
Beyer, Matthias [1 ]
Pietruske, Heiko [1 ]
Carl, Helmar [1 ]
机构
[1] Forschungszentrum Dresden Rossendorf EV, Inst Safety Res, D-01314 Dresden, Germany
[2] Gadjah Mada Univ, Fac Engn, Dept Mech & Ind Engn, Yogyakarta 55281, Indonesia
关键词
D O I
10.1016/j.nucengdes.2008.08.003
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An experimental investigation on the air/water counter-current two-phase flow in a horizontal rectangular channel connected to an inclined riser has been conducted. This test-section representing a model of the hot leg of a pressurized water reactor is mounted between two separators in a pressurized experimental vessel. The cross-section and length of the horizontal part of the test-section are (0.25 m x 0.05 m) and 2.59 m, respectively, whereas the inclination angle of the riser is 50 degrees. The flow was captured by a highspeed camera in the bended region of the hot leg, delivering a detailed view of the stratified interface as well as of dispersed structures like bubbles and droplets. Countercurrent flow limitation (CCFL), or the onset of flooding, was found by analyzing the water levels measured in the separators. The counter-current flow limitation is defined as the maximum air mass flow rate at which the discharged water mass flow rate is equal to the inlet water mass flow rate. From the high-speed observations it was found that the initiation of flooding coincides with the formation of slug flow. Furthermore, a hysteresis was noticed between flooding and deflooding. The CCFL data was compared with similar experiments and empirical correlations available in the literature. Therefore, the Wallis-parameter was calculated for the rectangular cross-sections by using the channel height as length, instead of the diameter. The agreement of the CCFL Curve is good, but the zero liquid penetration was found at lower values of the Wallis parameter than in most of the previous work. This deviation can be attributed to the special rectangular geometry of the hot leg model of FZD, since the other investigations were done for pipes. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:3389 / 3402
页数:14
相关论文
共 24 条
[1]  
[Anonymous], J KOREAN NUCL SOC
[2]   FLOODING IN AN ELBOW BETWEEN A VERTICAL AND A HORIZONTAL OR NEAR-HORIZONTAL PIPE .2. THEORY [J].
ARDRON, KH ;
BANERJEE, S .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1986, 12 (04) :543-558
[3]  
BECKER KM, 1978, KTHNEL25
[4]   HYSTERESIS EFFECT IN FLOODING [J].
CELATA, GP ;
CUMO, M ;
FARELLO, GE ;
SETARO, T .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1991, 17 (02) :283-289
[5]   EXPERIMENTAL STUDIES OF FLOODING IN NEARLY HORIZONTAL PIPES [J].
CHOI, KY ;
NO, HC .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1995, 21 (03) :419-436
[6]   COUNTERCURRENT GAS-LIQUID FLOW IN A PRESSURIZED-WATER REACTOR HOT LEG [J].
DEBERTODANO, ML .
NUCLEAR SCIENCE AND ENGINEERING, 1994, 117 (02) :126-133
[7]   Investigation of liquid film behavior at the onset of flooding during adiabatic counter-current air-water two-phase flow in an inclined pipe [J].
Deendarlianto ;
Ousaka, A ;
Kariyasaki, A ;
Fukano, T .
NUCLEAR ENGINEERING AND DESIGN, 2005, 235 (21) :2281-2294
[9]  
HEWITT GF, 1966, R4022 UKAEA AERE
[10]  
HIHARA E, 1985, NIPPON KIKAI GAKKAI, V51, P394