Microchip electrophoresis based multiplexed assay for silver and mercury ions simultaneous detection in complex samples using a stirring bar modified with encoded hairpin probes for specific extraction

被引:16
作者
Chen, Xixue [1 ]
Hong, Feng [1 ]
Zhang, Weilin [1 ]
Wu, Dazhen [1 ]
Li, Tianhua [1 ]
Hu, Futao [2 ]
Gan, Ning [1 ]
Lin, Jianyuan [3 ]
Wang, Qiqin [4 ]
机构
[1] Ningbo Univ, Fac Mat Sci & Chem Engn, Ningbo 31521, Zhejiang, Peoples R China
[2] Ningbo Univ, Fac Marine, Ningbo 31521, Zhejiang, Peoples R China
[3] Zhejiang Wanli Univ, Ningbo 315100, Zhejiang, Peoples R China
[4] Jinan Univ, Coll Pharm, Inst Pharmaceut Anal, Guangzhou 510632, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Microchip electrophoresis; Heavy metal ions; Multiplexed strategy; Complex samples; Stirring bar; Encoded hairpin probes; CONTACTLESS CONDUCTIVITY DETECTION; ICP-MS; CAPILLARY; HG2+; AG+; GOLD; SPECTROMETRY; STRATEGY; AGENT; STRIP;
D O I
10.1016/j.chroma.2019.01.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It is crucially important to rapidly, simultaneously, and sensitively determine trace amounts of heavy metal ions in complex samples. Herein, a stirring bar modified with two kinds of encoded hairpin DNA probes (H-0 and H-0') was used in a multiplexed strategy allowing for specific extraction of Hg2+ and Ag+ coupled to microchip electrophoresis (MCE) separation and LED induced fluorescence (LIF) detection. The extraction step utilizes stir bars, which are functionalized with designed hairpin DNA probes (H-0 with T-T and H-0' with C-C mismatches in stems). This allows the specific capture of Hg2+ and Ag+ through C-Ag+-C and T-Hg2+-T interactions. These complexes are then enzymatically degraded by the action of exonuclease III (Exo III). The ions released during this enzymatic reaction can initiate a new cycle of interactions with hairpin structures and enzymatic reactions and so on. This cyclic step is specific to the presence of Hg2+ and Ag+ and represents the first round of amplification of the presence of the selected ions. The resulting single strand DNAs on the stirring bars after enzymatic degradation were used in the second step as primers to trigger the catalytic hairpin assembly (CHA) in the presence of a couple of hairpin structures in solution. Such a reaction allows producing duplexes that can be monitored by MCE-LIF. The fluorescence intensity of CHA products (I-P) increased and that of hairpin DNAs (I-R) decreased with the increase of target concentrations. The signal ratios (I-P/I-R and I-P'/I-R') consisted of targets. The assay was employed for Hg2+ and Ag+ detection in several mediums including water, milk, and fish samples with complex matrices. The results showed that the assay could avoid matrix interference to increase the sensitivity. Therefore, the multiplexed assay was ideal to simultaneously and quickly detect metal ions in complex samples. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:173 / 181
页数:9
相关论文
共 42 条
  • [41] Colorimetric detection of genetically modified organisms based on exonuclease III-assisted target recycling and hemin/G-quadruplex DNAzyme amplification
    Zhang, Decai
    Wang, Weijia
    Dong, Qian
    Huang, Yunxiu
    Wen, Dongmei
    Mu, Yuejing
    Yuan, Yong
    [J]. MICROCHIMICA ACTA, 2018, 185 (01)
  • [42] Chemiluminescence Resonance Energy Transfer-Based Detection for Microchip Electrophoresis
    Zhao, Shulin
    Huang, Yong
    Shi, Ming
    Liu, Rongjun
    Liu, Yi-Ming
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (05) : 2036 - 2041