An in vitro evaluation of cone-beam breast CT methods

被引:0
作者
Zeng, Kai [5 ]
Fajardo, Laurie L. [4 ]
Kao, Simon [4 ]
Franken, Edmund A. [4 ]
Park, Jeong Mi [4 ]
Jing, Zhenxue [3 ]
Bai, Er-wei [2 ]
Wang, Ge [1 ]
机构
[1] Virginia Polytech Inst & State Univ, VT WFU Sch Biomed Engn & Sci, Blacksburg, VA 24061 USA
[2] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
[3] Hologic Inc, Bedford, MA 01730 USA
[4] Univ Iowa, Dept Radiol, Iowa City, IA 52242 USA
[5] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
关键词
Cone-beam CT; tomosynthesis; mammography; breast imaging; image quality;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Tomosynthesis was developed for mammography, especially breast cancer detection. However, its limited-angular range scan and resultant data incompleteness causes strong image artifacts and distortions. To address this problem, a hybrid imaging method was proposed in our previous work, which combines tomosynthesis and low-resolution CT into a single system to produce fewer artifacts and distortions at a similar dose level. The purpose of this paper is to evaluate the images reconstructed using the proposed method as compared with that using the conventional tomosynthesis method (ML-convex). For that purpose, the projection datasets are acquired in both numerical simulation and phantom experiments on our breast imaging platform. Three kinds of phantoms are used in our work, including a numerical phantom, a physical phantom and 8 in vitro phantoms made of breast specimens. In addition to visual comparison of the reconstructed images, we employ spatial resolution, image contrast, reconstruction error, and convergence rate to evaluate the results quantitatively. It is observed that the results from our method can achieve significantly higher spatial resolution, higher contrast, smaller reconstruction error and faster convergence rate. Besides, a reader study using 8 in vitro phantoms of breast specimens demonstrates the clinical potential of our method, which significantly outperforms the conventional tomosynthesis.
引用
收藏
页码:171 / 187
页数:17
相关论文
共 25 条
[1]   An adapted fan volume sampling scheme for 3-D algebraic reconstruction in linear tomosynthesis [J].
Bleuet, P ;
Guillemaud, R ;
Desbat, L ;
Magnin, I .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2366-2372
[2]   Comparison of MR imaging sequences for liver and head and neck interventions: Is there a single optimal sequence for all purposes? [J].
Boll, DT ;
Lewin, JS ;
Duerk, JL ;
Aschoff, AJ ;
Merkle, EM .
ACADEMIC RADIOLOGY, 2004, 11 (05) :506-515
[3]   SELF-MASKING SUBTRACTION TOMOSYNTHESIS [J].
CHAKRABORTY, DP ;
YESTER, MV ;
BARNES, GT ;
LAKSHMINARAYANAN, AV .
RADIOLOGY, 1984, 150 (01) :225-229
[4]   Digital x-ray tomosynthesis: current state of the art and clinical potential [J].
Dobbins, JT ;
Godfrey, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :R65-R106
[5]  
GAUVREAU MPK, 2000, PRINCIPLES BIOSTATIS
[6]  
GODFREY DJ, 2003, MED IMAGING 2003 PHY
[7]   ALGEBRAIC RECONSTRUCTION TECHNIQUES (ART) FOR 3-DIMENSIONAL ELECTRON MICROSCOPY AND X-RAY PHOTOGRAPHY [J].
GORDON, R ;
BENDER, R ;
HERMAN, GT .
JOURNAL OF THEORETICAL BIOLOGY, 1970, 29 (03) :471-&
[9]   GLOBALLY CONVERGENT ALGORITHMS FOR MAXIMUM A-POSTERIORI TRANSMISSION TOMOGRAPHY [J].
LANGE, K ;
FESSLER, JA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1995, 4 (10) :1430-1438
[10]  
LANGE K, 1984, J COMPUT ASSIST TOMO, V8, P306