摘要
We present the design, construction, and performance of a prototype multigap resistive plate chamber made of glass plates. A time resolution of 580 ps with a detection efficiency above 95% was achieved at the working high-voltage plateau with cosmic ray muons.
引用
收藏
页码:366 / 368
页数:3
相关论文
共 50 条
  • [21] Characteristics and performance of the Multigap Resistive Plate Chambers of the EEE experiment
    Coccetti, F.
    Abbrescia
    Avanzini, C.
    Baldini, L.
    Ferroli, R. Baldini
    Batignani, G.
    Battaglieri, M.
    Boi, S.
    Bossini, E.
    Carnesecchi, F.
    Cicalo, C.
    Cifarelli, L.
    Coccia, E.
    Corvaglia, A.
    De Gruttola, D.
    De Pasquale, S.
    Fabbri, F.
    Falchieri, D.
    Galante, L.
    Garbini, M.
    Gemme, G.
    Gnesi, I
    Grazzi, S.
    Hatzifotiadou, D.
    La Rocca, P.
    Liu, Z.
    Lombardo, L.
    Mandaglio, G.
    Maron, G.
    Mazziotta, Mn
    Mulliri, A.
    Nania, R.
    Noferini, F.
    Nozzoli, F.
    Palmonari, F.
    Panareo, M.
    Panetta, M. P.
    Paoletti, R.
    Parvis, M.
    Pellegrino, C.
    Perasso, L.
    Pinazza, O.
    Pinto, C.
    Pisano, S.
    Riggi, F.
    Righini, G.
    Ripoli, C.
    Rizzi, M.
    Sartorelli, G.
    Scapparone, E.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (11):
  • [22] A 20 ps timing device - A Multigap Resistive Plate Chamber with 24 gas gaps
    An, S.
    Jo, Y. K.
    Kim, J. S.
    Kim, M. M.
    Hatzifotiadou, D.
    Williams, M. C. S.
    Zichichi, A.
    Zuyeuski, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 594 (01): : 39 - 43
  • [23] Effect of adding SF6 to the gas mixture in a multigap resistive plate chamber
    Zeballos, EC
    Hatzifotiadou, D
    Kim, DW
    Lee, SC
    Lamas-Valverde, J
    Roberts, J
    Platner, E
    Williams, MCS
    Zichichi, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (2-3): : 475 - 478
  • [24] A large Time of Flight array for the ALICE experiment based on the Multigap Resistive Plate Chamber
    Williams, MCS
    NUCLEAR PHYSICS A, 1999, 661 : 707C - 711C
  • [25] Operation of the multigap resistive plate chamber using a gas mixture free of flammable components
    Akindinov, A
    Alici, A
    Antonioli, P
    Arcelli, S
    Basile, M
    Romeo, GC
    Cifarelli, L
    Cindolo, F
    De Caro, A
    De Pasquale, S
    Di Bartolomeo, A
    Girard, MF
    Golovine, V
    Guida, M
    Hatzifotiadou, D
    Kaidalov, AB
    Kim, DH
    Kim, DW
    Kisselev, SM
    Laurenti, G
    Lee, K
    Lee, SC
    Lioublev, E
    Luvisetto, ML
    Margotti, A
    Martemiyanov, AN
    Nania, R
    Noferini, F
    Otiougova, P
    Pesci, A
    Pinazza, O
    Polozov, PA
    Scapparone, E
    Scioli, G
    Sellitto, SB
    Semeria, F
    Smirnitski, AV
    Tchoumakova, MM
    Usenko, E
    Valenti, G
    Voloshin, KG
    Williams, MCS
    Zagreev, BV
    Zampolli, C
    Zichichi, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (03): : 515 - 519
  • [26] Study of gas mixtures and ageing of the multigap resistive plate chamber used for the Alice TOF
    Akindinov, AV
    Alici, A
    Anselmo, F
    Antonioli, P
    Basile, M
    Romeo, GC
    Cifarelli, L
    Cindolo, F
    Cosenza, F
    D'Antone, I
    De Caro, A
    De Pasquale, S
    Di Bartolomeo, A
    Girard, MF
    Golovine, V
    Guerzoni, M
    Guida, M
    Hatzifotiadou, D
    Kaidalov, AB
    Kim, DH
    Kim, DW
    Kisselev, SM
    Laurenti, G
    Lioublev, E
    Lee, K
    Lee, SC
    Luvisetto, ML
    Margotti, A
    Martemiyanov, AN
    Massera, F
    Meneghini, S
    Michinelli, R
    Nania, R
    Otiougova, P
    Pancaldi, G
    Pesci, A
    Pilastrini, R
    Pinazza, O
    Polozov, PA
    Rizzi, M
    Scapparone, E
    Scioli, G
    Sellitto, SB
    Semeria, F
    Serra, S
    Smirnitski, AV
    Tchoumakov, MM
    Ugolini, E
    Usenko, E
    Valenti, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 533 (1-2): : 93 - 97
  • [27] Performance of multigap resistive plate chambers with pure Freon 134a
    Doroud, K.
    Hatzifotiadou, D.
    Kim, D. W.
    Kim, J. S.
    Kim, M. M.
    Seo, J.
    Williams, M. C. S.
    Zichichi, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 629 (01): : 106 - 110
  • [28] Performance of the multigap resistive plate chambers of the extreme energy events project
    Garbini, M.
    Abbrescia, M.
    Avanzini, C.
    Baldinia, L.
    Ferroli, R. Baldini
    Batignani, L. G.
    Battaglieri, M.
    Boi, S.
    Bossini, E.
    Carnesecchi, F.
    Chiavassa, A.
    Cicalo, C.
    Cifarelli, L.
    Coccetti, F.
    Coccia, E.
    Corvaglia, A.
    De Gruttola, D.
    De Pasquale, S.
    Fabbri, L.
    Frolov, V
    Galante, L.
    Galeotti, P.
    Gemme, G.
    Gnesi, I
    Grazzi, S.
    Gustavino, C.
    Hatzifotiadou, D.
    La Rocca, P.
    Mandaglio, G.
    Rodriguez, O. Maragoto
    Maron, G.
    Mazziotta, M. N.
    Miozzi, S.
    Nania, R.
    Noferini, F.
    Nozzoli, F.
    Palmonari, F.
    Panareo, M.
    Panetta, M. P.
    Paoletti, R.
    Pellegrino, C.
    Park, W.
    Perasso, L.
    Pilo, F.
    Piragino, G.
    Pisano, S.
    Riggi, F.
    Righini, G. C.
    Ripoli, C.
    Rizzi, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 474 - 475
  • [29] Performance of a resistive plate chamber equipped with a new prototype of amplified front-end electronics
    Marchisone, Massimiliano
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [30] Studying the counting rate capability of a glass multigap resistive plate chamber at an increased operating temperature
    V. A. Gapienko
    O. P. Gavrishchuk
    A. A. Golovin
    A. A. Semak
    S. Ya. Sychkov
    Yu. M. Sviridov
    E. A. Usenko
    M. N. Ukhanov
    Instruments and Experimental Techniques, 2013, 56 : 265 - 270