An improved amperometric L-lactate biosensor based on covalent immobilization of microbial lactate oxidase onto carboxylated multiwalled carbon nanotubes/copper nanoparticles/polyaniline modified pencil graphite electrode

被引:48
作者
Dagar, Kusum [1 ]
Pundir, C. S. [1 ]
机构
[1] Maharshi Dayanand Univ, Dept Biochem, Rohtak 124001, Haryana, India
关键词
L-Lactate oxidase; Lactic acid; Copper nanoparticles; Carboxylated multiwalled carbon nanotubes; Polyaniline; Pencil graphite electrode; LACTIC-ACID; BLOOD LACTATE; DEHYDROGENASE; FILM; POLYANILINE; SYSTEM; COLUMN; SERUM; SHOCK; SALT;
D O I
10.1016/j.enzmictec.2016.10.014
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An improved amperometric L-lactate biosensor was constructed based on covalent immobilization of lactate oxidase (LOx) from Pediococcus species onto carboxylated multiwalled carbon nanotubes (cMWCNT)/copper nanoparticles (CuNPs)/polyaniline (PANI) hybrid film electrodeposited on the surface of a pencil graphite electrode (PGE). The enzyme electrode was characterized by cyclic voltammetry (CV), scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy and electrochemical impedance spectroscopy (EIS), while CuNPs synthesized by chemical reduction method, were characterized by transmission electron microscopy (TEM), UV spectrascopy and X-ray diffraction (XRD). The biosensor showed maximum response within 5 s at pH 8.0 in 0.05 M sodium phosphate buffer and 37 degrees C, when operated at 20 mV s(-1). The biosensor had a detection limit of 0.25 mu M with a wide working range between 1 mu M-2500 mu M. The biosensor was employed for measurement of L-lactic acid level in plasma of apparently healthy and diseased persons. Analytical recovery of added lactic acid in plasma was 95.5%. Within-and between-batch coefficients of variations were 6.24% and 4.19% respectively. There was a good correlation (R-2 = 0.97) between plasma lactate values as measured by standard enzymatic spectrophotometric method and the present biosensor. The working enzyme electrode was used 180 times over a period of 140 days, when stored at 4 degrees C. (C) 2016 Published by Elsevier Inc.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 59 条
[1]  
AVERY B. F., 1931, JOUR BIOL CHEM, V94, P273
[2]   A novel amperometric biosensor based on gold nanoparticles anchored on reduced graphene oxide for sensitive detection of L-lactate tumor biomarker [J].
Azzouzi, Sawsen ;
Rotariu, Lucian ;
Benito, Ana M. ;
Maser, Wolfgang K. ;
Ben Ali, Mounir ;
Bala, Camelia .
BIOSENSORS & BIOELECTRONICS, 2015, 69 :280-286
[3]  
Barker SB, 1941, J BIOL CHEM, V138, P535
[4]   An acrylamide biosensor based on immobilization of hemoglobin onto multiwalled carbon nanotube/copper nanoparticles/polyaniline hybrid film [J].
Batra, Bhawna ;
Lata, Suman ;
Sharma, Madhu ;
Pundir, C. S. .
ANALYTICAL BIOCHEMISTRY, 2013, 433 (02) :210-217
[5]   Diamond nanoparticles as a way to improve electron transfer in sol-gel L-lactate biosensing platforms [J].
Briones, M. ;
Casero, E. ;
Vazquez, L. ;
Pariente, F. ;
Lorenzo, E. ;
Petit-Dominguez, M. D. .
ANALYTICA CHIMICA ACTA, 2016, 908 :141-149
[6]   Sequential analysis of malic acid and both enantiomers of lactic acid in wine using a high-performance liquid chromatographic column-switching procedure [J].
Buglass, AJ ;
Lee, SH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2001, 39 (11) :453-458
[7]   Indirect ultraviolet detection of biologically relevant organic acids by capillary electrophoresis [J].
Chen, H ;
Xu, Y ;
VanLente, F ;
Ip, MPC .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 679 (1-2) :49-59
[8]   Application of a long shelf-life biosensor for the analysis of L-lactate in dairy products and serum samples [J].
Choi, MMF .
FOOD CHEMISTRY, 2005, 92 (03) :575-581
[9]   THE RELATIVE PROGNOSTIC VALUE OF LACTATE AND HEMODYNAMIC MEASUREMENTS IN EARLY SHOCK [J].
COWAN, BN ;
BURNS, HJG ;
BOYLE, P ;
LEDINGHAM, IM .
ANAESTHESIA, 1984, 39 (08) :750-755
[10]  
Ding M, 1998, Se Pu, V16, P59