Objective measurement of compliance during oral appliance therapy for sleep-disordered breathing

被引:166
作者
Vanderveken, Olivier M. [1 ,5 ,6 ]
Dieltjens, Marijke [2 ,6 ]
Wouters, Kristien [3 ]
De Backer, Wilfried A. [4 ,5 ,6 ]
Van de Heyning, Paul H. [1 ,5 ,6 ]
Braem, Marc J. [2 ,6 ]
机构
[1] Univ Antwerp Hosp, Dept Otolaryngol & Head & Neck Surg, B-2650 Antwerp, Belgium
[2] Univ Antwerp Hosp, Dept Special Care Dent, B-2650 Antwerp, Belgium
[3] Univ Antwerp Hosp, Dept Sci Coordinat & Biostat, B-2650 Antwerp, Belgium
[4] Univ Antwerp Hosp, Dept Pneumol, B-2650 Antwerp, Belgium
[5] Univ Antwerp Hosp, Multidisciplinary Sleep Disorders Unit, B-2650 Antwerp, Belgium
[6] Univ Antwerp, Fac Med & Hlth Sci, B-2020 Antwerp, Belgium
关键词
POSITIVE AIRWAY PRESSURE; MANDIBULAR ADVANCEMENT DEVICES; APNOEA/HYPOPNOEA SYNDROME; PRACTICE PARAMETERS; APNEA; EFFICACY; HYPERTENSION; ADHERENCE; UPDATE; ADULTS;
D O I
10.1136/thoraxjnl-2012-201900
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background Oral appliance (OA) therapy is increasingly prescribed as a non-continuous positive airway pressure treatment modality for sleep-disordered breathing (SDB). Although OA therapy is reported to be efficacious for the treatment of SDB, data on compliance remain limited to self-report. Methods In this 3-month prospective clinical trial, the main outcome was to assess the safety and feasibility of an objective measurement of compliance during OA therapy using an embedded microsensor thermometer with on-chip integrated readout electronics in 51 consecutive patients with an established diagnosis of SDB (AHI 18.0 +/- 11.9/h; age 47 +/- 10 y; BMI 26.6 +/- 4.0 kg/m(2); men/women: 31/20). Patients were unaware of the purpose of the study. Results No microsensor-related adverse events were recorded. In addition, no problems were encountered during the readout of the compliance data. Out of 51 microsensors, one had a technical defect and was lost to follow-up. In this study, the overall objective mean rate of OA use was 6.6 +/- 1.3 h per day with a regular OA users' rate of 82% at the 3-month follow-up. Statistical analysis revealed no significant differences between objective and self-reported OA compliance data in this study. Measurement of the objective OA compliance allowed us to calculate the mean disease alleviation (MDA) as the product of objective compliance and therapeutic efficacy. MDA serves as a measure of the overall therapeutic effectiveness, and turned out to be 51.1%. Conclusions The results illustrate the safety and feasibility of objective measurement of OA compliance. The objective measurement of OA compliance allows for calculation of the MDA.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 36 条
[11]   Oral appliance therapy reduces blood pressure in obstructive sleep apnea: A randomized, controlled trial [J].
Gotsopoulos, H ;
Kelly, JJ ;
Cistulli, PA .
SLEEP, 2004, 27 (05) :934-941
[12]   Therapy with nCPAP: incomplete elimination of Sleep Related Breathing Disorder [J].
Grote, L ;
Hedner, J ;
Grunstein, R ;
Kraiczi, H .
EUROPEAN RESPIRATORY JOURNAL, 2000, 16 (05) :921-927
[13]   NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE TREATMENT FOR OBSTRUCTIVE SLEEP-APNEA [J].
GRUNSTEIN, RR .
THORAX, 1995, 50 (10) :1106-1113
[14]   Efficacy and safety of temperature data loggers in measuring compliance with the use of oral appliances [J].
Inoko, Yoshimi ;
Yoshimura, Ken ;
Kato, Chihomi ;
Morita, Osami ;
Kohno, Masaki .
SLEEP AND BIOLOGICAL RHYTHMS, 2009, 7 (03) :188-192
[15]   Health, social and economical consequences of sleep-disordered breathing: a controlled national study [J].
Jennum, Poul ;
Kjellberg, Jakob .
THORAX, 2011, 66 (07) :560-566
[16]   OBJECTIVE MEASUREMENT OF PATTERNS OF NASAL CPAP USE BY PATIENTS WITH OBSTRUCTIVE SLEEP-APNEA [J].
KRIBBS, NB ;
PACK, AI ;
KLINE, LR ;
SMITH, PL ;
SCHWARTZ, AR ;
SCHUBERT, NM ;
REDLINE, S ;
HENRY, JN ;
GETSY, JE ;
DINGES, DF .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04) :887-895
[17]  
KRIEGER J, 1988, EUR RESPIR J, V1, P436
[18]   Practice parameters for the indications for polysomnography and related procedures: An update for 2005 [J].
Kushida, CA ;
Littner, MR ;
Morgenthaler, T ;
Alessi, CA ;
Bailey, D ;
Coleman, J ;
Friedman, L ;
Hirshkowitz, M ;
Kapen, S ;
Kramer, M ;
Lee-Chiong, T ;
Loube, DL ;
Owens, J ;
Pancer, JP ;
Wise, M .
SLEEP, 2005, 28 (04) :499-521
[19]   Practice parameters for the treatment of snoring and obstructive sleep apnea with oral appliances: An update for 2005 [J].
Kushida, Clete A. ;
Morgenthaler, Timothy I. ;
Littner, Michael R. ;
Alessi, Cathy A. ;
Bailey, Dennis ;
Coleman, Jack, Jr. ;
Friedman, Leah ;
Hirshkowitz, Max ;
Kapen, Sheldon ;
Kramer, Milton ;
Lee-Chiong, Teofilo ;
Owens, Judith ;
Pancer, Jeffrey P. .
SLEEP, 2006, 29 (02) :240-243
[20]   Comparison of Adjustable and Fixed Oral Appliances for the Treatment of Obstructive Sleep Apnea [J].
Lettieri, Christopher J. ;
Paolino, Nathalie ;
Eliasson, Arn H. ;
Shah, Anita A. ;
Holley, Aaron B. .
JOURNAL OF CLINICAL SLEEP MEDICINE, 2011, 7 (05) :439-445