Characteristics and international comparability of the Finnish matrix sentence test in cochlear implant recipients

被引:19
作者
Dietz, Aarno [1 ]
Buschermohle, Michael [2 ,3 ,4 ]
Sivonen, Ville [5 ]
Willberg, Tytti [1 ]
Aarnisalo, Antti A. [5 ]
Lenarz, Thomas [3 ,4 ,6 ]
Kollmeier, Birger [2 ,3 ,4 ,7 ]
机构
[1] Kuopio Univ Hosp, Dept Otorhinolaryngol, FI-70029 Kuopio, Finland
[2] HorTech gGmbH, Oldenburg, Germany
[3] Hearing4all, Cluster Excellence, Oldenburg, Germany
[4] Hearing4all, Cluster Excellence, Hannover, Germany
[5] Univ Helsinki, Cent Hosp, Dept Otorhinolaryngol, Helsinki, Finland
[6] Hannover Med Sch, Dept Otorhinolaryngol Head & Neck Surg, Hannover, Germany
[7] Carl von Ossietzky Univ Oldenburg, Med Phys, D-26111 Oldenburg, Germany
关键词
Cochlear implant; speech perception; noise; psychoacoustics; hearing science; SPEECH-INTELLIGIBILITY TESTS; HEARING; NOISE; DISCRIMINATION; RECOGNITION; THRESHOLD; LISTENERS;
D O I
10.3109/14992027.2015.1070309
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: The first Finnish sentence-based speech test in noisethe Finnish matrix sentence testwas recently developed. The aim of this study was to determine the characteristics of the new test with respect to test-retest reliability, speech recognition curve, and international comparability in Finnish cochlear implant (CI) recipients. Design: The speech reception thresholds (SRT) were measured by means of an adaptive test procedure and compared with the results of the traditional Finnish word test. Additional measurements for concurrent slope and SRT estimation were conducted to determine the speech recognition curve and to check the test-retest reliability. Study sample: The measurements were performed on 78 Finnish CI recipients. In a subset of 25 patients, additional measurements for test-retest reliability and slope determination were performed. Results: The mean SRT was - 3.5 +/- 1.7 dB SNR, with only a weak correlation with the Finnish word test. Test-retest reliability was within +/- 1 dB and the mean slope of the speech recognition curve was 14.6 +/- 3.6 %/dB. The rehabilitation results were similar to the results published for the German matrix test. Conclusions: The Finnish matrix test was found to be suitable and efficient in CI recipients with similar characteristics as the German matrix test.
引用
收藏
页码:80 / 87
页数:8
相关论文
共 44 条
[1]  
[Anonymous], ISO825332012
[2]  
[Anonymous], 1997, IEC6064521997
[3]  
Arnoldner Christoph, 2013, Cochlear Implants Int, V14 Suppl 4, pS10, DOI 10.1179/1467010013Z.000000000123
[4]  
Bosman AJ, 1995, AUDIOLOGY, V34, P260
[5]  
Boyd Paul J, 2015, Cochlear Implants Int, V16, P121, DOI 10.1179/1754762814Y.0000000100
[6]   Efficient adaptive procedures for threshold and concurrent slope estimates for psychophysics and speech intelligibility tests [J].
Brand, T ;
Kollmeier, B .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2002, 111 (06) :2801-2810
[7]   BINAURAL SPEECH-INTELLIGIBILITY IN NOISE FOR HEARING-IMPAIRED LISTENERS [J].
BRONKHORST, AW ;
PLOMP, R .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1989, 86 (04) :1374-1383
[8]  
Buchner A., 2011, COCHLEAR IMPLANTS IN, V12, P194
[9]  
Buschermohle M., 2014, Z AUDIOL, V53, P94
[10]   Comparison of Bimodal and Bilateral Cochlear Implant Users on Speech Recognition With Competing Talker, Music Perception, Affective Prosody Discrimination, and Talker Identification [J].
Cullington, Helen E. ;
Zeng, Fan-Gang .
EAR AND HEARING, 2011, 32 (01) :16-30