Experimental study on the transport properties of fluorinated ethers

被引:5
作者
Matsuo, S [1 ]
Tanaka, Y [1 ]
Sotani, T [1 ]
机构
[1] Kobe Univ, Fac Engn, Dept Chem Sci & Engn, Nada Ku, Kobe, Hyogo 6578501, Japan
关键词
falling-body viscometer; fluorinated ether; high pressure; thermal conductivity; transient hot-wire method; viscosity;
D O I
10.1016/S0378-3812(01)00793-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
Liquid thermal conductivities of HFE-245mc (pentafluoroethyl methyl ether) are presented over the temperature range from 275 to 323 K and at pressures up to 10 MPa. The excess thermal conductivities have been determined according to the residual concept for transport properties to express the thermal conductivity in a wide temperature and pressure range. Liquid viscosities of HFE-245mc are also presented at temperatures from 298 to 348 K and pressures up to 20 MPa. The saturated liquid thermal conductivities and viscosities of HFE-245mc have been determined by the use of simple correlation equations and compared to those of CFC-114. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:1205 / 1213
页数:9
相关论文
共 11 条
[1]   THEORY OF TRANSIENT HOT-WIRE METHOD FOR MEASURING THERMAL-CONDUCTIVITY [J].
HEALY, JJ ;
DEGROOT, JJ ;
KESTIN, J .
PHYSICA B & C, 1976, 82 (02) :392-408
[2]  
*JAP ASS REFR, 1993, HDB JAR FUND
[3]   VISCOSITY OF LIGHT AND HEAVY-WATER AND THEIR MIXTURES [J].
KESTIN, J ;
IMAISHI, N ;
NOTT, SH ;
NIEUWOUDT, JC ;
SENGERS, JV .
PHYSICA A, 1985, 134 (01) :38-58
[4]   Gaseous thermal conductivities of fluorinated methyl ethyl ethers [J].
Matsuo, S ;
Tanaka, Y ;
Takada, N ;
Yamamoto, H ;
Sekiya, A .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 1998, 43 (03) :473-476
[5]  
Matsuo S., 1998, REV HIGH PRESSURE SC, V7, P1189
[6]  
OHTA H, 1998, P 19 JAP S THERM PRO, P291
[7]   Critical properties of fluorinated ethers [J].
Sako, T ;
Sato, M ;
Nakazawa, N ;
Oowa, M ;
Yasumoto, M ;
Ito, H ;
Yamashita, S .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 1996, 41 (04) :802-805
[8]  
TANAKA Y, 1977, REV PHYS CHEM JPN, V47, P12
[9]  
TSUGE T, 1998, REV HIGH PRESSURE SC, V7, P1198
[10]  
WIDIATMO JV, 2000, P 2 WORKSH THERM PRO, P26