Impact of implant surface topography: a clinical study with a mean functional loading time of 85 months

被引:13
作者
Arnhart, Christoph [1 ]
Dvorak, Gabriella [1 ]
Trefil, Caroline [1 ]
Huber, Christian [2 ]
Watzek, Georg [1 ]
Zechner, Werner [1 ]
机构
[1] Med Univ Vienna, Bernhard Gottlieb Univ Clin Dent, Div Oral Surg, A-1090 Vienna, Austria
[2] Med Univ Vienna, Bernhard Gottlieb Univ Clin Dent, Div Oral Surg, Ludwig Boltzmann Inst, A-1090 Vienna, Austria
关键词
anodized surface; dental implant; long-term results; machined; moderately rough; peri-implant bone loss; turned; FOLLOW-UP; MANDIBULAR OVERDENTURES; BONE LOSS; DENTAL IMPLANTS; LONG-TERM; SURVIVAL;
D O I
10.1111/j.1600-0501.2012.02498.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: Moderately rough, surfaced implants are widely used. Nevertheless data on long-term soft and hard tissue parameters are still conflicting. The purpose of this study was to evaluate peri-implant bone level and soft tissue integration of anodized vs. turned surfaced implants in the anterior mandible after a mean functional loading time of 85 months. Methods: Of 114 edentulous patients invited for follow-up, 41,2% were available for recall. Forty-seven patients with a mean age of 71 +/- 9 years (14 men and 33 women) received 188 dental implants; All patients were edentulous and prosthetic rehabilitation was carried out by a bar-retained overdenture. Radiographic peri-implant bone level was assessed twice at baseline and recall. Clinical examination contained peri-implant sounding (PPD, BoP) and indexing oral hygiene (mPI). Results: From baseline up to 85 months two patients experienced implant loss (four implants), which corresponds to an overall-survival rate of 97.9%. No significant differences were found between implant surfaces concerning the clinical parameters, such as plaque, calculus, bleeding on probing and pocket probing depth. The moderately rough surfaced implants showed significantly less decrease in peri-implant bone level (1.53 +/- 0.25 mm) than turned surfaced implants (2.42 +/- 0.34 mm) (P = 0.036). The interaction between the position of the implant and surface topography (P = 0.037) as well as the site at the implant (P = 0.004) had a significant influence on bone level changes. Conclusion: Both surface topographies with bar-supported overdentures have excellent long-term clinical outcomes. Moreover, a moderately roughened, anodized surface has beneficial effects in the anterior lower jaw.
引用
收藏
页码:1049 / 1054
页数:6
相关论文
共 31 条
[1]  
Aalam AA, 2005, INT J ORAL MAX IMPL, V20, P793
[2]  
Albrektsson T, 2004, INT J PROSTHODONT, V17, P544
[3]   Astra Tech and Branemark system implants:: a 5-year prospective study of marginal bone reactions [J].
Åstrand, P ;
Engquist, B ;
Dahlgren, S ;
Gröndahl, K ;
Engquist, E ;
Feldmann, H .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :413-420
[4]  
Balshe AA, 2008, INT J ORAL MAX IMPL, V23, P1117
[5]  
Becker W, 2000, Clin Implant Dent Relat Res, V2, P159, DOI 10.1111/j.1708-8208.2000.tb00007.x
[6]   Spontaneous progression of ligature induced peri-implantitis at implants with different surface roughness: an experimental study in dogs [J].
Berglundh, T. ;
Gotfredsen, K. ;
Zitzmann, N. U. ;
Lang, N. P. ;
Lindhe, J. .
CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (05) :655-661
[7]  
Degidi M, 2009, INT J ORAL MAX IMPL, V24, P896
[8]  
Esposito M., 2007, COCHRANE DATABASE SY, V18
[9]  
Friberg Bertil, 2010, Clin Implant Dent Relat Res, V12 Suppl 1, pe95, DOI 10.1111/j.1708-8208.2009.00222.x
[10]   A split-mouth comparative study up to 16 years of two screw-shaped titanium implant systems [J].
Jacobs, Reinhilde ;
Pittayapat, Pisha ;
van Steenberghe, Daniel ;
De Mars, Greet ;
Gijbels, Frieda ;
Van der Donck, Annelies ;
Li, Limin ;
Liang, Xin ;
Van Assche, Nele ;
Quirynen, Marc ;
Naert, Ignace .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2010, 37 (12) :1119-1127