Biodiesel content determination in diesel fuel blends using near infrared (NIR) spectroscopy and support vector machines (SVM)

被引:87
作者
Alves, Julio Cesar L. [1 ]
Poppi, Ronei J. [1 ]
机构
[1] State Univ Campinas UNICAMP, Inst Chem, POB 6154, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Biodiesel; Diesel fuel; Support vector machines; Near infrared (NIR) spectroscopy; LEAST-SQUARES REGRESSION; DIESEL/BIODIESEL BLENDS; QUALITY PARAMETERS; MULTIVARIATE CALIBRATION; VARIABLE SELECTION; ETHANOL-DIESEL; PLS; MODELS; CLASSIFICATION; ADULTERATION;
D O I
10.1016/j.talanta.2012.11.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work verifies the potential of support vector machine (SVM) algorithm applied to near infrared (NIR) spectroscopy data to develop multivariate calibration models for determination of biodiesel content in diesel fuel blends that are more effective and appropriate for analytical determinations of this type of fuel nowadays, providing the usual extended analytical range with required accuracy. Considering the difficulty to develop suitable models for this type of determination in an extended analytical range and that, in practice, biodiesel/diesel fuel blends are nowadays most often used between 0 and 30% (v/v) of biodiesel content, a calibration model is suggested for the range 0-35% (v/v) of biodiesel in diesel blends. The possibility of using a calibration model for the range 0-100% (v/v) of biodiesel in diesel fuel blends was also investigated and the difficulty in obtaining adequate results for this full analytical range is discussed. The SVM models are compared with those obtained with PLS models. The best result was obtained by the SVM model using the spectral region 4400-4600 cm(-1) providing the RMSEP value of 0.11% in 0-35% biodiesel content calibration model. This model provides the determination of biodiesel content in agreement with the accuracy required by ABNT NBR and ASTM reference methods and without interference due to the presence of vegetable oil in the mixture. The best SVM model fit performance for the relationship studied is also verified by providing similar prediction results with the use of 4400-6200 cm(-1) spectral range while the PLS results are much worse over this spectral region. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:155 / 161
页数:7
相关论文
共 57 条
[1]   Quality analysis of wintertime B6-B20 biodiesel blend samples collected in the United States [J].
Alleman, Teresa L. ;
Fouts, Lisa ;
McCormick, Robert L. .
FUEL PROCESSING TECHNOLOGY, 2011, 92 (07) :1297-1304
[2]   Diesel oil quality parameter determinations using support vector regression and near infrared spectroscopy for hydrotreating feedstock monitoring [J].
Alves, Julio Cesar L. ;
Poppi, Ronei J. .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2012, 20 (04) :419-425
[3]   Determination of diesel quality parameters using support vector regression and near infrared spectroscopy for an in-line blending optimizer system [J].
Alves, Julio Cesar L. ;
Henriques, Claudete B. ;
Poppi, Ronei J. .
FUEL, 2012, 97 :710-717
[4]  
Amaral D. F., 2009, DESMISTIFICANDO PROG
[5]  
[Anonymous], 2009, A practical guide to support vector classification
[6]  
[Anonymous], 2011, PLAN DEC EXP EN 2020
[7]  
[Anonymous], 2007, D7371 ASTM INT, DOI [10.1520/D7371-07, DOI 10.1520/D7371-07]
[8]  
[Anonymous], 2008, 15568 ABNT NBR ASS B
[9]  
[Anonymous], 2009, D7467 ASTM INT, DOI [10.1520/D7467-09a, DOI 10.1520/D7467-09A]
[10]  
[Anonymous], 2002, COMPR AN B IN PRESS