Corneal pachymetry mapping with high-speed optical coherence tomography

被引:197
作者
Li, Y
Shekhar, R
Huang, D
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Cleveland Clin Fdn, Dept Biomed Engn, Cleveland, OH USA
[3] Cleveland Clin Fdn, Cole Eye Inst, Cleveland, OH USA
关键词
D O I
10.1016/j.ophtha.2006.01.048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To map corneal thickness before and after LASIK with optical coherence tomography (OCT). Design: Cross-sectional observational study. Participants: Forty-two eyes of 21 normal subjects undergoing LASIK. Methods: A high-speed (2000 axial scans/second) 1.3-mu m-wavelength corneal and anterior segment OCT prototype was used for corneal scanning. The scan pattern consisted of 10-mm radial lines on 8 meridians centered on the vertex reflection. The entire scan pattern of 1024 a-scans was acquired in 0.5 seconds. We developed automated computer processing for 3-dimensional corneal reconstruction and measurement. Corneal thickness was measured normal to the anterior surface and presented as color pachymetry maps and zonal statistics. The maps were divided into a central zone (< 2 mm) and 3 annular areas (pericentral, 2-5 mm; transitional, 5-7 mm; peripheral, 7-10 mm), which were further divided into quadrantal zones. The average, minimum, and maximum corneal thicknesses were computed for zones within the 7-mm diameter. Optical coherence tomography and ultrasound pachymetry were measured 3 times at the preoperative and 3-month postoperative visits. Reproducibility was assessed by the pooled standard deviations (SDs) of the repeated measurements. Main Outcome Measures: Optical coherence tomography pachymetric map and zonal statistic, and ultrasound pachymetry. Results: Before LASIK, central corneal thicknesses (CCTs) were 546.9 +/- 29.4 mu m (mean +/- SD) for OCT and 553.3 +/- 33.0 mu m for ultrasound. After LASIK, CCTs were 513.7 +/- 44.5 mu m for OCT and 498 +/- 46.6 mu m for ultrasound. Optical coherence tomography and ultrasound CCT were highly correlated (Pearson correlation r = 0.97 before LASIK and 0.98 afterwards). Optical coherence tomography CCT was slightly less than ultrasound CCT before surgery (mean difference, -6.4 mu m; 95% limits of agreement, -23.2 to 10.4 mu m) but slightly greater after LASIK (15.7 mu m; -1.6 to 33 mu m). These differences were statistically significant, but no more than the CCT measurement differences between ultrasound pachymeters. The reproducibility of the OCT zonal pachymetry averages was roughly 2 Am. Conclusions: High-speed OCT provided noncontact, rapid, reproducible pachymetric mapping over a wide area of the cornea. It is equivalent to ultrasound for CCT measurement before and after LASIK This technology could be valuable for planning keratorefractiveprocedures and diagnosis of corneal diseases.
引用
收藏
页码:792 / 799
页数:8
相关论文
共 63 条
  • [11] Ex vivo confocal microscopy of human LASIK corneas with histologic and ultrastructural correlation
    Dawson, DG
    Holley, GP
    Geroski, DH
    Waring, GO
    Grossniklaus, HE
    Edelhauser, HF
    [J]. OPHTHALMOLOGY, 2005, 112 (04) : 634 - 644
  • [12] Long-term histopathologic findings in human corneal wounds after refractive surgical procedures
    Dawson, DG
    Edelhauser, HF
    Grossniklaus, HE
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (01) : 168 - 178
  • [13] Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    Doughty, MJ
    Zaman, ML
    [J]. SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) : 367 - 408
  • [14] Comparison of corneal pachymetry using ultrasound and Orbscan II
    Fakhry, MA
    Artola, A
    Belda, JL
    Ayala, MJ
    Alió, JL
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) : 248 - 252
  • [15] Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography
    Feng, YW
    Varikooty, J
    Simpson, TL
    [J]. CORNEA, 2001, 20 (05) : 480 - 483
  • [16] Assessment of central corneal thickness using optical coherence tomography
    Fishman, GR
    Pons, ME
    Seedor, JA
    Liebmann, JM
    Ritch, R
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04) : 707 - 711
  • [17] Corneal pachymetry in normal and keratoconic eyes: Orbscan II versus ultrasound
    Gherghel, D
    Hosking, SL
    Mantry, S
    Banerjee, S
    Naroo, SA
    Shah, S
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (06) : 1272 - 1277
  • [18] Anterior chamber width measurement by high speed optical coherence tomography
    Goldsmith, JA
    Li, Y
    Chalita, MR
    Westphal, V
    Patil, CA
    Rollins, AM
    Izatt, JA
    Huang, D
    [J]. OPHTHALMOLOGY, 2005, 112 (02) : 238 - 244
  • [19] Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry
    González-Méijome, JM
    Cerviño, A
    Yebra-Pimentel, E
    Parafita, MA
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01) : 125 - 132
  • [20] Model for nonectatic increase in posterior corneal elevation after ablative procedures
    Grzybowski, DM
    Roberts, CJ
    Mahmoud, AM
    Chang, JS
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) : 72 - 81