Phenylboronic acid immunoaffinity reactor coupled with flow injection chemiluminescence for determination of α-fetoprotein

被引:40
作者
Wu, Yafeng [1 ]
Zhuang, Yafeng [2 ]
Liu, Songqin [1 ]
He, Lin [3 ]
机构
[1] Southeast Univ, Sch Chem & Chem Engn, Jiangsu Prov Key Lab Biomat & Biodevices, Nanjing 210096, Peoples R China
[2] Changzhou Inst Technol, Dept Chem, Changzhou 213022, Peoples R China
[3] N Carolina State Univ, Dept Chem, Raleigh, NC 27695 USA
基金
中国国家自然科学基金;
关键词
3-Aminophenylboronic acid; alpha-Fetoprotein; Immunoaffinity reactor; Regeneration; Flow injection chemiluminescence;
D O I
10.1016/j.aca.2008.10.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reusable and sensitive immunoassay based on phenylboronic acid immunoaffinity reactor in combination with flow injection chemiluminescence (CL) for determination of glycoprotein was described. The reactor was fabricated by immobilizing 3-aminophenylboronic acid (APBA) on glass microbeads with gamma-glycidoxypropyltrimethoxysilane (GPMS) as linkage. The a-fetoprotein (AFP) could be easily immobilized on the APBA coated beads through sugar-boronic interaction. After an off-line incubation, the mixture of the analyte AFP with horseradish peroxidase-labeled AFP antibody (HRP-anti-AFP) was injected into the reactor. This led the trapping of free HRP-anti-AFP by the surface coated AFP on glass beads. The trapped HRP-anti-AFP was detected by chemiluminescence due to its sensitizing effect on the reaction of luminol and hydrogen peroxide. Under optimal conditions, the chemiluminescent signal was proportional to AFP concentration in the range of 10-100 ng mL(-1). The whole assay process including regeneration of the reactor could be completed within 31 min. The proposed system showed acceptable detection and fabrication reproducibility, and the results obtained with the present method were in acceptable agreement with those from parallel single-analyte test of practical clinical sera. The described method enabled a low-cost, time saving and was potential to detect the serum AFP level in clinical diagnosis. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:186 / 193
页数:8
相关论文
共 47 条
  • [1] Immobilization of peroxidase glycoprotein on gold electrodes modified with mixed epoxy-boronic acid monolayers
    Abad, JM
    Vélez, M
    Santamaría, C
    Guisán, JM
    Matheus, PR
    Vázquez, L
    Gazaryan, I
    Gorton, L
    Gibson, T
    Fernández, VM
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (43) : 12845 - 12853
  • [2] DEMONSTRATION OF A NEW PROTEIN FRACTION IN SERUM FROM THE HUMAN FETUS
    BERGSTRAND, CG
    CZAR, B
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1956, 8 (02) : 174 - 174
  • [3] Surface imprinted beads for the recognition of human serum albumin
    Bonini, Francesca
    Piletsky, Sergey
    Turner, Anthony P. F.
    Speghini, Adolfo
    Bossi, Alessandra
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) : 2322 - 2328
  • [4] Molecularly imprinted polymers for the recognition of proteins: The state of the art
    Bossi, A.
    Bonini, F.
    Turner, A. P. F.
    Piletsky, S. A.
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (06) : 1131 - 1137
  • [5] Surface-grafted molecularly imprinted polymers for protein recognition
    Bossi, A
    Piletsky, SA
    Piletska, EV
    Righetti, PG
    Turner, APF
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (21) : 5281 - 5286
  • [6] Chou SF, 2002, CLIN CHEM, V48, P913
  • [7] Christiansen M, 2001, SCAND J CLIN LAB INV, V61, P205
  • [8] CI YX, 1995, ANAL CHIM ACTA, V300, P273
  • [9] Layer-by-layer hydroxymethyl ferrocene modified sensor for one-step flow/stop-flow injection amperometric immunoassay of α-fetoprotein
    Dai, Zong
    Serban, Simona
    Ju, Huangxian
    El Murr, Nabil
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (08) : 1700 - 1706
  • [10] Channel-resolved multianalyte immunosensing system for flow-through chemiluminescent detection of α-fetoprotein and carcinoembryonic antigen
    Fu, Zhifeng
    Yan, Feng
    Liu, Hong
    Yang, Zhanjun
    Ju, Huangxian
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 23 (07) : 1063 - 1069