Robust Vector Control of a Very Weak-Grid-Connected Voltage-Source Converter Considering the Phase-Locked Loop Dynamics

被引:166
作者
Davari, Masoud [1 ]
Mohamed, Yasser Abdel-Rady I. [1 ]
机构
[1] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2V4, Canada
关键词
AC-bus voltage control; grid-connected converters; phase-locked loop dynamics; robust control; vector control; voltage-source converters (VSCs); weak grids; VSC; DESIGN; STABILITY;
D O I
10.1109/TPEL.2016.2546341
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Conventional vector-controlled voltage-source converters (VSC) suffer from stability and performance problems when integrated into very weak ac grids (high-impedance grids). This is attributed to the increased coupling between the converter and grid dynamics, via the phase-locked loop (PLL), at the very weak-grid condition. In the current literature, the impact of the PLL is usually ignored when the converter controllers are designed. While this approach can be accepted under stiff grid conditions, it yields unmodeled dynamics that destabilize the converter under weak-grid conditions and high-power injection levels. To overcome this limitation, this paper presents a robust vector-controlled VSC that facilitates full converter power injection at weak and very weak-grid conditions (i.e., when the short-circuit capacity ratio is one). To realize the controller, first, a detailed dynamic model for the ac-bus voltage dynamics, including the PLL dynamics, is developed and validated in this paper. Second, the model is used to optimally design a robust ac-bus voltage controller to stabilize the dynamics under operating point variation and grid impedance uncertainty. Because the developed model includes the PLL dynamics, the developed controller inherently stabilizes the negative impact of the PLL on the converter stability. A theoretical analysis and comparative simulation and experimental results are provided to show the effectiveness of the proposed controller.
引用
收藏
页码:977 / 994
页数:18
相关论文
共 27 条
  • [1] [Anonymous], P 2003 IEEE C CONTR
  • [2] [Anonymous], 2015, MATL ROB CONTR TOOLB
  • [3] A phase tracking system for three phase utility interface inverters
    Chung, SK
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) : 431 - 438
  • [4] Variable-Structure-Based Nonlinear Control for the Master VSC in DC-Energy-Pool Multiterminal Grids
    Davari, Masoud
    Mohamed, Yasser Abdel-Rady I.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (11) : 6196 - 6213
  • [5] Analysis of Phase-Locked Loop Low-Frequency Stability in Three-Phase Grid-Connected Power Converters Considering Impedance Interactions
    Dong, Dong
    Wen, Bo
    Boroyevich, Dushan
    Mattavelli, Paolo
    Xue, Yaosuo
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (01) : 310 - 321
  • [6] Doyle J.C., 1992, Feedback Control Theory, P45
  • [7] Advanced Vector Control for Voltage Source Converters Connected to Weak Grids
    Egea-Alvarez, Agust
    Fekriasl, Sajjad
    Hassan, Fainan
    Gomis-Bellmunt, Oriol
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (06) : 3072 - 3081
  • [8] Grid to Standalone Transition Motion-Sensorless Dual-Inverter Control of PMSG With Asymmetrical Grid Voltage Sags and Harmonics Filtering
    Fatu, Marius
    Blaabjerg, Frede
    Boldea, Ion
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (07) : 3463 - 3472
  • [9] Goodwin G. C., 2000, CONTROL SYSTEM DESIG
  • [10] Gu D.-. W., 2005, ADV TK CONT SIGN PRO