Automatic selection of regularization parameters for dynamic fluorescence molecular tomography: a comparison of L-curve and U-curve methods

被引:14
作者
Chen, Maomao [1 ]
Su, Han [1 ]
Zhou, Yuan [1 ]
Cai, Chuangjian [1 ]
Zhang, Dong [1 ]
Luo, Jianwen [1 ,2 ]
机构
[1] Tsinghua Univ, Sch Med, Dept Biomed Engn, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Ctr Biomed Imaging Res, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
ILL-POSED PROBLEMS; OPTICAL TOMOGRAPHY; INDOCYANINE GREEN; STRUCTURAL PRIORS; PRINCIPLE; CHOICE;
D O I
10.1364/BOE.7.005021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Dynamic fluorescence molecular tomography (FMT) is a promising technique for the study of the metabolic process of fluorescent agents in the biological body in vivo, and the quality of the parametric images relies heavily on the accuracy of the reconstructed FMT images. In typical dynamic FMT implementations, the imaged object is continuously monitored for more than 50 minutes. During each minute, a set of the fluorescent measurements is acquired and the corresponding FMT image is reconstructed. It is difficult to manually set the regularization parameter in the reconstruction of each FMT image. In this paper, the parametric images obtained with the L-curve and U-curve methods are quantitatively evaluated through numerical simulations, phantom experiments and in vivo experiments. The results illustrate that the U-curve method obtains better accuracy, stronger robustness and higher noise-resistance in parametric imaging. Therefore, it is a promising approach to automatic selection of the regularization parameters for dynamic FMT. (C) 2016 Optical Society of America
引用
收藏
页码:5021 / 5041
页数:21
相关论文
共 34 条
[1]   Pharmacokinetic-rate images of indocyanine green for breast tumors using near-infrared optical methods [J].
Alacam, Burak ;
Yazici, Birsen ;
Intes, Xavier ;
Nioka, Shoko ;
Chance, Britton .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (04) :837-859
[2]   Direct Reconstruction of Pharmacokinetic-Rate Images of Optical Fluorophores From NIR Measurements [J].
Alacam, Burak ;
Yazici, Birsen .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (09) :1337-1353
[3]   Optical tomography in medical imaging [J].
Arridge, SR .
INVERSE PROBLEMS, 1999, 15 (02) :R41-R93
[4]   A discrepancy principle for generalized local regularization of linear inverse problems [J].
Brooks, Cara D. ;
Lamm, Patricia K. .
JOURNAL OF INVERSE AND ILL-POSED PROBLEMS, 2014, 22 (01) :95-119
[5]   Feasibility of U-curve method to select the regularization parameter for fluorescence diffuse optical tomography in phantom and small animal studies [J].
Chamorro-Servent, Judit ;
Aguirre, Juan ;
Ripoll, Jorge ;
Jose Vaquero, Juan ;
Desco, Manuel .
OPTICS EXPRESS, 2011, 19 (12) :11490-11506
[6]   Selection of regularization parameter for optical topography [J].
Correia, Teresa ;
Gibson, Adam ;
Schweiger, Martin ;
Hebden, Jeremy .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (03)
[7]   Three-dimensional diffuse optical tomography in the parallel plane transmission geometry: Evaluation of a hybrid frequency domain/continuous wave clinical system for breast imaging [J].
Culver, JP ;
Choe, R ;
Holboke, MJ ;
Zubkov, L ;
Durduran, T ;
Slemp, A ;
Ntziachristos, V ;
Chance, B ;
Yodh, AG .
MEDICAL PHYSICS, 2003, 30 (02) :235-247
[8]   Image-guided diffuse optical fluorescence tomography implemented with Laplacian-type regularization [J].
Davis, Scott C. ;
Dehghani, Hamid ;
Wang, Jia ;
Jiang, Shudong ;
Pogue, Brian W. ;
Paulsen, Keith D. .
OPTICS EXPRESS, 2007, 15 (07) :4066-4082
[9]   GENERALIZED CROSS-VALIDATION AS A METHOD FOR CHOOSING A GOOD RIDGE PARAMETER [J].
GOLUB, GH ;
HEATH, M ;
WAHBA, G .
TECHNOMETRICS, 1979, 21 (02) :215-223
[10]   A Combined Fluorescence and Microcomputed Tomography System for Small Animal Imaging [J].
Guo, Xiaolian ;
Liu, Xin ;
Wang, Xin ;
Tian, Feng ;
Liu, Fei ;
Zhang, Bin ;
Hu, Guangshu ;
Bai, Jing .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (12) :2876-2883