Influence of Electrochemical Polishing on the Mechanical Properties of K3 Nickel-Titanium Rotary Instruments

被引:22
作者
Galvao Barbosa, Fabiola Ormiga [1 ]
da Cunha Ponciano Gomes, Jose Antonio [1 ]
Pimenta de Araujo, Marcos Cesar [2 ]
机构
[1] Univ Fed Rio de Janeiro, Dept Met & Mat, Rio De Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, Dept Endodont, Rio De Janeiro, Brazil
关键词
Electrochemical polishing; endodontic instrument; fracture; nickel-titanium;
D O I
10.1016/j.joen.2008.08.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Instrument fracture is a serious concern in endodontic treatment. Several studies have evaluated the influence of various factors on the fracture of nickel-titanium endodontic rotary instruments. The present study analyzes the influence of electrochemical polishing on flexural fatigue and torsional properties of K3 nickel-titanium endodontic rotary instruments. New files and polished files were tested for flexural fatigue and for resistance to fracture by twisting. The t test was used to compare the groups for number of cycles, angle of rotation, and maximum torque necessary to fracture. No statistical difference existed between these groups. Scanning electron microscopy analysis showed no significant differences caused by electrochemical polishing between these groups. These results suggest that electrochemical polishing has no influence on resistance to fracture of K3 rotary instruments. (J Endod 2008;34:1533-1536)
引用
收藏
页码:1533 / 1536
页数:4
相关论文
共 29 条
[1]   SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use [J].
Alapati, SB ;
Brantley, WA ;
Svec, TA ;
Powers, JM ;
Nusstein, JM ;
Daehn, GS .
JOURNAL OF ENDODONTICS, 2005, 31 (01) :40-43
[2]   SEM observations and differential scanning calorimetric studies of new and sterilized nickel-titanium rotary endodontic instruments [J].
Alexandrou, Georgia B. ;
Chrissafis, Konstantinos ;
Vasiliadis, Leonidas P. ;
Pavlidou, Eleni ;
Polychroniadis, E. K. .
JOURNAL OF ENDODONTICS, 2006, 32 (07) :675-679
[3]   Fracture resistance of electropolished rotary nickel-titanium endodontic instruments [J].
Anderson, Margot E. ;
Price, John W. H. ;
Parashos, Peter .
JOURNAL OF ENDODONTICS, 2007, 33 (10) :1212-1216
[4]   Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments: Value of the safety quotient [J].
Blum, JY ;
Machtou, P ;
Ruddle, C ;
Micallef, JP .
JOURNAL OF ENDODONTICS, 2003, 29 (09) :567-575
[5]   A comparison of torque required to fracture three different nickel-titanium rotary instruments around curves of the same angle but of different radius when bound at the tip [J].
Booth, JR ;
Scheetz, JP ;
Lemons, JE ;
Eleazer, PD .
JOURNAL OF ENDODONTICS, 2003, 29 (01) :55-57
[6]   Effect of electropolishing ProFile nickel-titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency [J].
Bui, Tung B. ;
Mitchell, John C. ;
Baumgartner, J. Craig .
JOURNAL OF ENDODONTICS, 2008, 34 (02) :190-193
[7]  
Busslinger A, 1998, INT ENDOD J, V31, P290
[8]   Does electropolishing improve the low-cycle fatigue behavior of a nickel-titanium rotary instrument in hypochlorite? [J].
Cheung, Gary S. P. ;
Shen, Ya ;
Darvell, Brian W. .
JOURNAL OF ENDODONTICS, 2007, 33 (10) :1217-1221
[9]   Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions [J].
Darabara, M ;
Bourithis, L ;
Zinelis, S ;
Papadimitriou, GD .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (10) :705-710
[10]   Fractographic analysis of K3 nickel-titanium rotary instruments submitted to different modes of mechanical loading [J].
Galvao Barbosa, Fabiola Ormiga ;
Ponciano Gomes, Jose Antonio da Cunha ;
de Araujo, Marcos Cesar Pimenta .
JOURNAL OF ENDODONTICS, 2008, 34 (08) :994-998