Performance evaluation of the portable MiniVOL particulate matter sampler

被引:38
作者
Baldauf, RW
Lane, DD
Marotz, GA
Wiener, RW
机构
[1] Univ Kansas, Dept Civil & Environm Engn, Lawrence, KS 66045 USA
[2] US EPA, Natl Exposure Res Lab, Res Triangle Pk, NC 27711 USA
关键词
air quality; monitoring; particulate matter; portable sampling; spatial distributions;
D O I
10.1016/S1352-2310(01)00403-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The MiniVOL sampler is a popular choice for use in air quality assessments because it is portable and inexpensive relative to fixed site monitors. However, little data exist on the performance characteristics of the sampler. The reliability, precision, and comparability of the portable MiniVOL PM10 and PM2.5 sampler under typical ambient conditions are described in this paper. Results indicate that the MiniVOL (a) operated reliably and (b) yielded statistically similar concentration measurements when co-located with another MiniVOL (r(2) = 0.96 for PM10, measurements and r(2) = 0.95 for PM2.5 measurements). Thus, the characterization of spatial distributions of PM10 and PM(2.)5 mass concentrations with the MiniVOL can be accomplished with a high level of confidence. The MiniVOL also produced statistically comparable results when co-located with a Dichotomous Sampler (r(2) = 0.83 for PM10 measurements and r(2) = 0.85 for PM2.5 measurements) and a continuous mass sampling system (r(2) = 0.90 for PM10 measurements). Environmental factors such as ambient concentration, wind speed, temperature, and humidity may influence the relative measurement comparability between these sampling systems. Published by Elsevier Science Ltd.
引用
收藏
页码:6087 / 6091
页数:5
相关论文
共 9 条
[1]   Evaluation of the TEOM(R) method for measurement of ambient particulate mass in urban areas [J].
Allen, G ;
Sioutas, C ;
Koutrakis, P ;
Reiss, R ;
Lurmann, FW ;
Roberts, PT .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (06) :682-689
[2]   TEOM vs. manual gravimetric methods for determination of PM2.5 aerosol mass concentrations [J].
Ayers, GP ;
Keywood, MD ;
Gras, JL .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (22) :3717-3721
[3]  
BALDAUF RW, 1997, LESSONS LEARNED USE
[4]  
BERG NJ, 1990, 1990 AIR WAST MAN AS
[5]  
CHOW JC, 1994, NEV MONITORING ASSES, V30, P39
[6]  
COWHERD C, 1998, P 91 ANN AIR WAST MA
[7]  
LIN YJ, 1997, P 90 ANN AIR WAST MA
[8]  
PLEASANT M, 1994, US EPA SPECIAL PUBLI
[9]   Field trials of the TEOM® and Partisol for PM10 monitoring in the St Austell china clay area, Cornwall, UK [J].
Salter, LF ;
Parsons, B .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (13) :2111-2114