Estimation of the limit of detection in semiconductor gas sensors through linearized calibration models

被引:110
作者
Burgues, Javier [1 ,2 ]
Manuel Jimenez-Soto, Juan [2 ]
Marco, Santiago [1 ,2 ]
机构
[1] Univ Barcelona, Dept Elect & Biomed Engn, Marti & Franques 1, E-08028 Barcelona, Spain
[2] Barcelona Inst Sci & Technol, Inst Bioengn Catalonia IBEC, Signal & Informat Proc Sensing Syst, Baldiri Reixac 10-12, Barcelona 08028, Spain
关键词
Semiconductor gas sensors; Metal-oxide sensors; Limit of detection; Non-linear; Humidity interference; Temperature modulation; QUANTIFICATION; QUALITY;
D O I
10.1016/j.aca.2018.01.062
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The limit of detection (LOD) is a key figure of merit in chemical sensing. However, the estimation of this figure of merit is hindered by the non-linear calibration curve characteristic of semiconductor gas sensor technologies such as, metal oxide (MOX), gasFETs or thermoelectric sensors. Additionally, chemical sensors suffer from cross-sensitivities and temporal stability problems. The application of the International Union of Pure and Applied Chemistry (IUPAC) recommendations for univariate LOD estimation in non-linear semiconductor gas sensors is not straightforward due to the strong statistical requirements of the IUPAC methodology (linearity, homoscedasticity, normality). Here, we propose a methodological approach to LOD estimation through linearized calibration models. As an example, the methodology is applied to the detection of low concentrations of carbon monoxide using MOX gas sensors in a scenario where the main source of error is the presence of uncontrolled levels of humidity. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:13 / 25
页数:13
相关论文
共 42 条
  • [1] [Anonymous], 2013, ANAL CHIM ACTA
  • [2] [Anonymous], HUM OLFACTORY DISPLA
  • [3] [Anonymous], SENS C
  • [4] [Anonymous], 2015, Advancing Sustainable Materials Management: 2013 Fact Sheet- Assessing Trends in Material Generation, Recycling and Disposal in the United States, P1
  • [5] [Anonymous], TGS203 CARBON MONOXI
  • [6] [Anonymous], SB50012 FIS
  • [7] Bârsan N, 2003, J PHYS-CONDENS MAT, V15, pR813, DOI 10.1088/0953-8984/15/20/201
  • [8] Pilot Study of the Use of Personal Carbon Monoxide Monitoring to Achieve Radical Smoking Reduction
    Beard, Emma
    West, Robert
    [J]. JOURNAL OF SMOKING CESSATION, 2012, 7 (01): : 12 - 17
  • [9] Comparison of metal oxide-based electronic nose end mess spectrometry-based electronic nose for the prediction of red wine spoilage
    Berna, Amalia Z.
    Trowell, Stephen
    Cynkar, Wies
    Cozzolino, Daniel
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (09) : 3238 - 3244
  • [10] Multivariate detection limits with fixed probabilities of error
    Boqué, R
    Larrechi, MS
    Rius, FX
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 45 (1-2) : 397 - 408