The Measurement of a Nonlinear Resonant Decay Using Continuous-Scan Laser Doppler Vibrometry

被引:0
|
作者
Ehrhardt, David A. [1 ]
Allen, Matthew S. [2 ]
Beberniss, Timothy J. [3 ]
机构
[1] UES Air Force Res Lab, Wright Patterson AFB, OH 45433 USA
[2] Univ Wisconsin, Dept Engn Phys, 1500 Engn Dr, Madison, WI 53706 USA
[3] US Air Force, Struct Sci Ctr, Aerosp Syst Directorate, Res Lab, Wright Patterson AFB, OH 45433 USA
关键词
Continuous-scan laser Doppler vibrometry; 3D digital image correlation; Resonant decay; VIBRATION;
D O I
10.1007/978-3-319-54648-3_10
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The nonlinear resonant decay of a structure offers much insight into the frequency-amplitude behavior of a structure's dynamic response. The spatial deformation during this decay is especially important since nonlinear responses can cause unexpected stress concentrations necessitating full-field measurements for comparison with a model. In this context, full-field measurement techniques, such as continuous scan laser Doppler vibrometry (CSLDV) and high speed three dimensional digital image correlation (3D-DIC) provide tools to obtain the full-field dynamic response experimentally. While CSLDV has been used to measure the steady state response of linear and nonlinear structures as well as transient responses of linear structures, it is unclear whether the approach can be successful for transient nonlinear measurements where the frequency of the dynamic response is amplitude dependent. In this investigation, the capabilities of CSLDV will be utilized to measure the nonlinear resonant decay of a clamped-clamped flat beam. The response measured using CSLDV will then be compared with the decay response measured with 3D-DIC to validate the CSLDV method and to understand the advantages and disadvantages of each.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [31] Variation of Localized Nonlinear Acoustic Parameters around a Crack Tip using a Laser Doppler Vibrometry
    Cheong, Yong-Moo
    Kim, Kyung-Jung
    Jung, Hyun-Kyu
    NDT IN PROGRESS 2011, PROCEEDINGS, 2011, : 89 - 91
  • [32] Infrared intracavity laser absorption spectroscopy with a continuous-scan Fourier-transform interferometer
    Cheng, JX
    Lin, H
    Hu, SM
    He, SG
    Zhu, QS
    Kachanov, A
    APPLIED OPTICS, 2000, 39 (13) : 2221 - 2229
  • [33] A High-Resolution Continuous-Scan Acoustic Measurement Method for Turbofan Engine Applications
    Shah, Parthiv N.
    Vold, Havard
    Hensley, Dan
    Envia, Edmane
    Stephens, David
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2015, 137 (12):
  • [34] Facial Muscle Activity: High-Sensitivity Noncontact Measurement Using Laser Doppler Vibrometry
    Casaccia, Sara
    Sirevaag, Erik J.
    Frank, Mark G.
    O'Sullivan, Joseph A.
    Scalise, Lorenzo
    Rohrbaugh, John W.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [35] Development of a robot-aided modal analysis measurement method using laser Doppler vibrometry
    Devigne, O.
    Hoffait, S.
    Bruls, O.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2020) / INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2020), 2020, : 1847 - 1858
  • [36] Assessment of Coating Layers on the Accuracy of Displacement Measurement in Laser Doppler Vibrometry
    Hasanian, Mostafa
    Lissenden, Cliff J.
    43RD REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, 2017, 1806
  • [37] Laser tissue interaction with fs pulses: Measurement of the recoil momentum by laser Doppler vibrometry
    Sessa, G
    Travaglini, M
    Mittnacht, D
    Foth, HJ
    LASER-TISSUE INTERACTION XIV, 2003, 4961 : 60 - 65
  • [38] Laser tissue interaction with fs pulses: Measurement of the recoil momentum by Laser Doppler Vibrometry
    Mittnacht, D
    Sessa, G
    Travaglini, M
    Foth, HJ
    THERAPEUTIC LASER APPLICATIONS AND LASER-TISSUE INTERACTIONS, 2003, 5142 : 154 - 160
  • [39] Laser tissue interaction with fs pulses: Measurement of the recoil momentum by laser Doppler vibrometry
    Mittnacht, D
    Sessa, G
    Travaglini, M
    Foth, HJ
    SIXTH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 2004, 5503 : 116 - 123
  • [40] Vibration measurements using continuous scanning laser Doppler vibrometry: theoretical velocity sensitivity analysis with applications
    Halkon, BJ
    Rothberg, SJ
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (03) : 382 - 393