PRESSURE CONTROL OF THE PROPORTIONAL DIRECTIONAL CONTROL VALVE TEST RIG BASED ON THE FUZZY PROPORTIONAL-INTEGRAL-DOUBLE-INTEGRAL CONTROLLER

被引:0
作者
Shi, Wenzhuo [1 ]
Wei, Jianhua [1 ]
Fang, Jinhui [1 ]
Li, Mingjie [1 ]
Zhang, Qiang [1 ]
Qiao, Xining [1 ]
机构
[1] Zhejiang Univ, State Key Lab Fluid Power & Mechatron Syst, Hangzhou, Zhejiang, Peoples R China
来源
PROCEEDINGS OF THE ASME/BATH SYMPOSIUM ON FLUID POWER AND MOTION CONTROL, 2017 | 2017年
关键词
HYDRAULIC LOAD SIMULATOR; SLIDING MODE CONTROL; SOLENOID VALVE; FEEDBACK LINEARIZATION;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The pressure drop needs to be kept constant in the flow rate/input signal performance test of proportional directional control (PDC) valve. In general, the control of valve pressure drop is implemented by regulating the relief valve or flow control valve that located between port A and port B of the PDC valve. But in this study, the load of the test valve is fixed and the stable pressure drop is obtained by changing the proportional relief valve which is placed in the inlet of the PDC valve. Then the mathematical model of the test rig and several controllers are established based on this idea. To be specific, proportional-integral (P-I) controller, proportional-integral double integral (P-I-II) controller, and fuzzy proportional integral double-integral (FP-I-II) controller are all applied to stabilize the pressure drop in this study. And the FP-I-II controller with compensation (FP-I-II-WC) is proved to be the best for this work both in the simulation and the actual experiment.