Finite Element Study on the Micromotion of Cementless Total Hip Arthroplasty

被引:0
作者
Baharuddin, Mohd Yusof [1 ,2 ]
Kadir, Mohammed Rafiq Abdul [2 ]
机构
[1] Univ Malaysia Perlis, BEG, Kangar 01000, Perlis, Malaysia
[2] Univ Teknol Malaysia, Med Implant Technol Grp, Johor Baharu, Malaysia
来源
6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3 | 2010年 / 31卷
关键词
Total Hip Arthroplasty; micromotion; stability; FEMORAL COMPONENTS; COLLAR; PROSTHESIS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Major problem associated with the cementless design is the lack of stability. Several design features were introduced to provide the much needed stability for bone integration. These include fins, fiber mesh, beads, indentations and collars. The use of collar has been a subject of controversy with mixed reports of clinical outcomes. In this study, the effectiveness of collar in terms of providing stability was analysed using finite element method. Three dimensional model of a human femur was constructed from CT dataset and hip arthroplasty was simulated. With an applied joint contact load simulating physiological gait, micromotion of the implant relative to the bone was calculated via an experimentally validated algorithm. Results showed that collar did not improve stability of the whole stem but only around the medial calcar region.
引用
收藏
页码:605 / +
页数:2
相关论文
共 13 条
[1]  
Abdul Kadir MR, 2005, INTERFACE MICROMOTIO
[2]   NEW METHOD TO ANALYZE MECHANICAL BEHAVIOR OF SKELETAL PARTS [J].
BREKELMA.WA ;
SLOOFF, TJJH ;
POORT, HW .
ACTA ORTHOPAEDICA SCANDINAVICA, 1972, 43 (05) :301-&
[3]  
Dolinski K., 1999, Journal of Theoretical and Applied Mechanics, V3, P505
[4]   A critical assessment of proximal macrotexturing on cemented femoral components [J].
Duffy, GP ;
Muratoglu, OK ;
Biggs, SA ;
Larson, SL ;
Lozynsky, AJ ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :42-48
[5]   Finite element simulation of the hip joint during stumbling: a comparison between static and dynamic loading [J].
El'Sheikh, HF ;
MacDonald, BJ ;
Hashmi, MSJ .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2003, 143 :249-255
[6]   A 3-DIMENSIONAL NONLINEAR FINITE-ELEMENT STUDY OF THE EFFECT OF CEMENT-PROSTHESIS DEBONDING IN CEMENTED FEMORAL TOTAL HIP COMPONENTS [J].
HARRIGAN, TP ;
HARRIS, WH .
JOURNAL OF BIOMECHANICS, 1991, 24 (11) :1047-1058
[7]   THE INITIATION OF FAILURE IN CEMENTED FEMORAL COMPONENTS OF HIP ARTHROPLASTIES [J].
JASTY, M ;
MALONEY, WJ ;
BRAGDON, CR ;
OCONNOR, DO ;
HAIRE, T ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :551-558
[8]   EFFECTS OF POROUS COATING, WITH AND WITHOUT COLLAR SUPPORT, ON EARLY RELATIVE MOTION FOR A CEMENTLESS HIP-PROSTHESIS [J].
KEAVENY, TM ;
BARTEL, DL .
JOURNAL OF BIOMECHANICS, 1993, 26 (12) :1355-1368
[9]   Comparison of collared and collarless femoral components in primary uncemented total hip arthroplasty [J].
Meding, JB ;
Ritter, MA ;
Keating, EM ;
Faris, PM .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :273-280
[10]  
SOTEREANOS NG, 1995, CLIN ORTHOP RELAT R, P146