The cementless Bicontact® stem in a prospective dual-energy X-ray absorptiometry study

被引:17
作者
Lerch, Matthias [1 ]
Kurtz, Agnes [1 ]
Windhagen, Henning [1 ]
Bouguecha, Anas [2 ]
Behrens, Bernd A. [2 ]
Wefstaedt, Patrick [3 ]
Stukenborg-Colsman, Christina M. [1 ]
机构
[1] Hannover Med Sch, Dept Orthopaed Surg, D-30625 Hannover, Germany
[2] Leibniz Univ Hannover, Inst Forming Technol & Machines, Hannover, Germany
[3] Univ Vet Med Hannover, Small Anim Clin, Hannover, Germany
关键词
TOTAL-HIP-ARTHROPLASTY; BONE-MINERAL DENSITY; 4-YEAR FOLLOW-UP; FEMORAL IMPLANT; PROXIMAL FEMUR; PROSTHESIS; SYSTEM; DEXA; DXA; ENDOPROSTHESIS;
D O I
10.1007/s00264-012-1616-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The cementless BicontactA (R) total hip arthroplasty (THA) system (AESCULAP AG, Tuttlingen, Germany) was introduced in 1986/1987 and has been in successful clinical use in an unaltered form up to today. Although good long-term results with the BicontactA (R) stem have been published, it is questionable whether the implant provides the criteria for a state-of-the-art stem regarding proximal bone stock preservation. The purpose of the study was to monitor the periprosthetic bone mineral density (BMD) in a prospective two-year follow-up dual-energy X-ray absorptiometry (DEXA) study. After power analysis, a consecutive series of 25 patients with unilateral BicontactA (R) stem implantation was examined clinically and underwent DEXA examinations. Scans of seven regions of interest were taken preoperatively and at one week, six months, and one and two years. One patient required stem revision due to a deep infection. The Harris Hip Score increased significantly by 44 points. The most significant bone loss was observed in the calcar region (R7) in the first six months (-19.2 %). It recovered in the following 18 months to -8.5 %. The BMD in the greater trochanter dropped significantly after six months and remained stable at this level. BMD exceeded baseline values in distal regions and even more in the lesser trochanter region after two years. We conclude that the BicontactA (R) stem provides adequate proximal bone stock preservation. We observed some signs of stress shielding at the tip of the stem, which is inevitable to some degree in THA with cementless straight stems. However, in this prospective DEXA investigation, we showed that proximal off-loading does not occur after THA with the BicontactA (R) system. Thus, we believe that this stem is still a state-of-the-art implant.
引用
收藏
页码:2211 / 2217
页数:7
相关论文
共 40 条
  • [21] Precision of the measurements of periprosthetic bone mineral density in hips with a custom-made femoral stem
    Martini, F
    Lebherz, C
    Mayer, F
    Leichtle, U
    Kremling, E
    Sell, S
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (07): : 1065 - 1071
  • [22] Mortimer ES, 1996, CLIN ORTHOP RELAT R, P269
  • [23] MULLER ME, 1992, CLIN ORTHOP RELAT R, P12
  • [24] Effect of a stemless femoral implant for total hip arthroplasty on the bone mineral density of the proximal femur - A prospective longitudinal study
    Munting, E
    Smitz, P
    VanSante, N
    deDeuxchaisnes, CN
    Vincent, A
    Devogelaer, JP
    [J]. JOURNAL OF ARTHROPLASTY, 1997, 12 (04) : 373 - 379
  • [25] Nishii T, 1997, CLIN ORTHOP RELAT R, P121
  • [26] Prospective long-term follow-up of the cementless bicontact hip stem with plasmapore coating
    Ochs, U.
    Eingartner, C.
    Volkmann, R.
    Ochs, B. G.
    Huber, C.
    Weller, S.
    Weise, K.
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2007, 145 : S3 - S8
  • [27] Panisello J J, 2006, J Orthop Surg (Hong Kong), V14, P32
  • [28] Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss
    Rahmy, AIA
    Gosens, T
    Blake, GM
    Tonino, A
    Fogelman, I
    [J]. OSTEOPOROSIS INTERNATIONAL, 2004, 15 (04) : 281 - 289
  • [29] Changes of periprosthetic bone mineral density in cementless bicontact stem implantation; Influence of different parameters - a prospective 4-year follow-up
    Reiter, A
    Gellrich, JC
    Bachman, J
    Braun, A
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2003, 141 (03): : 283 - 288
  • [30] Roth A, 2005, ORTHOPADE, V34, P334, DOI 10.1007/s00132-005-0773-1