The cementless Bicontact® stem in a prospective dual-energy X-ray absorptiometry study

被引:17
作者
Lerch, Matthias [1 ]
Kurtz, Agnes [1 ]
Windhagen, Henning [1 ]
Bouguecha, Anas [2 ]
Behrens, Bernd A. [2 ]
Wefstaedt, Patrick [3 ]
Stukenborg-Colsman, Christina M. [1 ]
机构
[1] Hannover Med Sch, Dept Orthopaed Surg, D-30625 Hannover, Germany
[2] Leibniz Univ Hannover, Inst Forming Technol & Machines, Hannover, Germany
[3] Univ Vet Med Hannover, Small Anim Clin, Hannover, Germany
关键词
TOTAL-HIP-ARTHROPLASTY; BONE-MINERAL DENSITY; 4-YEAR FOLLOW-UP; FEMORAL IMPLANT; PROXIMAL FEMUR; PROSTHESIS; SYSTEM; DEXA; DXA; ENDOPROSTHESIS;
D O I
10.1007/s00264-012-1616-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The cementless BicontactA (R) total hip arthroplasty (THA) system (AESCULAP AG, Tuttlingen, Germany) was introduced in 1986/1987 and has been in successful clinical use in an unaltered form up to today. Although good long-term results with the BicontactA (R) stem have been published, it is questionable whether the implant provides the criteria for a state-of-the-art stem regarding proximal bone stock preservation. The purpose of the study was to monitor the periprosthetic bone mineral density (BMD) in a prospective two-year follow-up dual-energy X-ray absorptiometry (DEXA) study. After power analysis, a consecutive series of 25 patients with unilateral BicontactA (R) stem implantation was examined clinically and underwent DEXA examinations. Scans of seven regions of interest were taken preoperatively and at one week, six months, and one and two years. One patient required stem revision due to a deep infection. The Harris Hip Score increased significantly by 44 points. The most significant bone loss was observed in the calcar region (R7) in the first six months (-19.2 %). It recovered in the following 18 months to -8.5 %. The BMD in the greater trochanter dropped significantly after six months and remained stable at this level. BMD exceeded baseline values in distal regions and even more in the lesser trochanter region after two years. We conclude that the BicontactA (R) stem provides adequate proximal bone stock preservation. We observed some signs of stress shielding at the tip of the stem, which is inevitable to some degree in THA with cementless straight stems. However, in this prospective DEXA investigation, we showed that proximal off-loading does not occur after THA with the BicontactA (R) system. Thus, we believe that this stem is still a state-of-the-art implant.
引用
收藏
页码:2211 / 2217
页数:7
相关论文
共 40 条
  • [1] Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems 37 patients followed for 3 years
    Albanese, Carlina V.
    Santori, Francesco S.
    Pavan, Laura
    Learmonth, Ian D.
    Passariello, Roberto
    [J]. ACTA ORTHOPAEDICA, 2009, 80 (03) : 291 - 297
  • [2] Bone remodelling in THA: A comparative DXA scan study between conventional implants and a new stemless femoral component. A preliminary report
    Albanese, CV
    Rendine, M
    De Palma, F
    Impagliazzo, A
    Falez, F
    Postacchini, F
    Villani, C
    Passariello, R
    Santori, FS
    [J]. HIP INTERNATIONAL, 2006, 16 : S9 - S15
  • [3] Pattern of periprosthetic bone remodeling around stable uncemented tapered hip stems: A prospective 84-month follow-up study and a median 156-month cross-sectional study with DXA
    Aldinger, PR
    Sabo, D
    Pritsch, M
    Thomsen, M
    Mau, H
    Ewerbeck, V
    Breusch, SJ
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2003, 73 (02) : 115 - 121
  • [4] [Anonymous], 2012, Annual Report
  • [5] [Anonymous], 8 NAT JOINT REG ENGL
  • [6] BETTIN D, 1995, INT ORTHOP, V19, P144
  • [7] BOBYN JD, 1992, CLIN ORTHOP RELAT R, P79
  • [8] Continuous bone loss around a tapered uncemented femoral stem -: A long-term evaluation with DEXA
    Boden, Henrik S. G.
    Skoldenberg, Olof G.
    Salemyr, Mats F.
    Lundberg, Hans-Jerker
    Adolphson, Per Y.
    [J]. ACTA ORTHOPAEDICA, 2006, 77 (06) : 877 - 885
  • [9] The periprosthetic bone remodelling process - signs of vital bone reaction
    Braun, A
    Papp, J
    Reiter, A
    [J]. INTERNATIONAL ORTHOPAEDICS, 2003, 27 : S7 - S10
  • [10] Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty - A five-year longitudinal study
    Brodner, W
    Bitzan, P
    Lomoschitz, F
    Krepler, P
    Jankovsky, R
    Lehr, S
    Kainberger, F
    Gottsauner-Wolf, F
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (01): : 20 - 26