Label free biosensor for sensitive human influenza virus hemagglutinin specific antibody detection using coiled-coil peptide modified microelectrode array based platform

被引:34
作者
Arya, Sunil K. [1 ]
Kongsuphol, Patthara [1 ]
Wong, Chee Chung [1 ]
Polla, Lee Joseph [1 ]
Park, Mi Kyoung [1 ]
机构
[1] Inst Microelect, Singapore 117685, Singapore
关键词
Coiled-coil peptide; HA-antibody; Biosensor; Electrochemical impedance; Self-assembled monolayer; ELECTROCHEMICAL IMMUNOSENSOR; SALMONELLA-TYPHIMURIUM; ELECTRODE; INFECTION;
D O I
10.1016/j.snb.2013.12.066
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Coiled-coil peptide (CCP) modified microelectrode array with comb structure (MACS) has been utilized to fabricate an electrochemical biosensor for antibody detection. Thiol terminated CCP has been employed for self-assembling on MACS and peptide chains connecting amino acid sequence 98-106 (YPYDVPDYA) of human Influenza virus hemagglutinin (HA) has been used as a molecular receptor for HA-antibody. Electrochemical impedance (EIS) studies, cyclic voltammetry studies, atomic force microscopic imaging and contact angle measurements were utilized to characterize self-assembly of CCP on MACS surface. Further, EIS studies were used to investigate interaction between CCP and HA-antibody at different concentrations. EIS measurements revealed that the specific interaction of HA-antibody with CCP gives rise to a clear increase in the value of interfacial charge transfer resistance (R-ct). A linear relationship between R-ct and the logarithm of HA-antibody concentration was found for the concentration range of 1 pg ml(-1) to 100 ng ml(-1), with a detection limit of 1 pg ml(-1). Negligible change of R-ct was observed by incubating the sensor in solutions of other proteins such DO1, anti-GFAP, anti-IL6 and BSA, suggesting high selectivity of descried immunosensor for HA-antibody. These results demonstrated that the CCP modified MACS based platform can provide a versatile matrix for sensitive detection of desired target. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 27 条
  • [11] Integrated disposable electrochemical immunosensors for the simultaneous determination of sulfonamide and tetracycline antibiotics residues in milk
    Conzuelo, Felipe
    Campuzano, Susana
    Gamella, Maria
    Pinacho, Daniel G.
    Julio Reviejo, A.
    Pilar Marco, M.
    Pingarron, Jose M.
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 50 : 100 - 105
  • [12] A label-free electrochemical impedance immunosensor based on AuNPs/PAMAM-MWCNT-Chi nanocomposite modified glassy carbon electrode for detection of Salmonella typhimurium in milk
    Dong, Jing
    Zhao, Han
    Xu, Minrong
    Ma, Qiang
    Ai, Shiyun
    [J]. FOOD CHEMISTRY, 2013, 141 (03) : 1980 - 1986
  • [13] Electrochemical impedance immunosensor based on gold nanoparticles-protein G for the detection of cancer marker epidermal growth factor receptor in human plasma and brain tissue
    Elshafey, Reda
    Tavares, Ana C.
    Siaj, Mohamed
    Zourob, Mohammed
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 50 : 143 - 149
  • [14] Recognition of Salmonella typhimurium by immobilized phage P22 monolayers
    Handa, Hitesh
    Gurczynski, Stephen
    Jackson, Matthew P.
    Auner, Gregory
    Walker, Jeremy
    Mao, Guangzhao
    [J]. SURFACE SCIENCE, 2008, 602 (07) : 1392 - 1400
  • [15] Impedance Biosensor for Peanut Protein Ara h 1
    Huang, Yin
    Bell, Melissa C.
    Suni, Ian I.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (23) : 9157 - 9161
  • [16] Nanoparticle-based biosensor for the detection of emerging pandemic influenza strains
    Kamikawa, Tracy L.
    Mikolajczyk, Malgorzata G.
    Kennedy, Michael
    Zhang, Pei
    Wang, Wei
    Scott, Dorothy E.
    Alocilja, Evangelyn C.
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 26 (04) : 1346 - 1352
  • [17] Mediator and label free estimation of stress biomarker using electrophoretically deposited Ag@AgO-polyaniline hybrid nanocomposite
    Kaushik, Ajeet
    Vasudev, Abhay
    Arya, Sunil K.
    Bhansali, Shekhar
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 50 : 35 - 41
  • [18] Planar electrochemical sensors for biomedical applications
    Laschi, Serena
    Mascini, Marco
    [J]. MEDICAL ENGINEERING & PHYSICS, 2006, 28 (10) : 934 - 943
  • [19] Electrochemical impedance spectroscopy for study of aptamer-thrombin interfacial interactions
    Li, Xiaoxia
    Shen, Lihua
    Zhang, Dongdong
    Qi, Honglan
    Gao, Qiang
    Ma, Fen
    Zhang, Chengxiao
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 23 (11) : 1624 - 1630
  • [20] Designing heterodimeric two-stranded α-helical coiled-coils -: Effects of hydrophobicity and α-helical propensity on protein folding, stability, and specificity