Label free biosensor for sensitive human influenza virus hemagglutinin specific antibody detection using coiled-coil peptide modified microelectrode array based platform

被引:34
作者
Arya, Sunil K. [1 ]
Kongsuphol, Patthara [1 ]
Wong, Chee Chung [1 ]
Polla, Lee Joseph [1 ]
Park, Mi Kyoung [1 ]
机构
[1] Inst Microelect, Singapore 117685, Singapore
关键词
Coiled-coil peptide; HA-antibody; Biosensor; Electrochemical impedance; Self-assembled monolayer; ELECTROCHEMICAL IMMUNOSENSOR; SALMONELLA-TYPHIMURIUM; ELECTRODE; INFECTION;
D O I
10.1016/j.snb.2013.12.066
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Coiled-coil peptide (CCP) modified microelectrode array with comb structure (MACS) has been utilized to fabricate an electrochemical biosensor for antibody detection. Thiol terminated CCP has been employed for self-assembling on MACS and peptide chains connecting amino acid sequence 98-106 (YPYDVPDYA) of human Influenza virus hemagglutinin (HA) has been used as a molecular receptor for HA-antibody. Electrochemical impedance (EIS) studies, cyclic voltammetry studies, atomic force microscopic imaging and contact angle measurements were utilized to characterize self-assembly of CCP on MACS surface. Further, EIS studies were used to investigate interaction between CCP and HA-antibody at different concentrations. EIS measurements revealed that the specific interaction of HA-antibody with CCP gives rise to a clear increase in the value of interfacial charge transfer resistance (R-ct). A linear relationship between R-ct and the logarithm of HA-antibody concentration was found for the concentration range of 1 pg ml(-1) to 100 ng ml(-1), with a detection limit of 1 pg ml(-1). Negligible change of R-ct was observed by incubating the sensor in solutions of other proteins such DO1, anti-GFAP, anti-IL6 and BSA, suggesting high selectivity of descried immunosensor for HA-antibody. These results demonstrated that the CCP modified MACS based platform can provide a versatile matrix for sensitive detection of desired target. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 27 条
  • [1] A stable and sensitive voltammetric immunosensor based on a new non-enzymatic label
    Akter, Rashida
    Rhee, Choong Kyun
    Rahman, Md. Aminur
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 50 : 118 - 124
  • [2] Effects of the Electrode Size and Modification Protocol on a Label-Free Electrochemical Biosensor
    Arya, Sunil K.
    Pui, Tze Sian
    Wong, Chee Chung
    Kumar, Sai
    Rahman, Abdur Rub Abdur
    [J]. LANGMUIR, 2013, 29 (22) : 6770 - 6777
  • [3] Antibody functionalized interdigitated μ-electrode (IDμE) based impedimetric cortisol biosensor
    Arya, Sunil K.
    Chornokur, Ganna
    Venugopal, Manju
    Bhansali, Shekhar
    [J]. ANALYST, 2010, 135 (08) : 1941 - 1946
  • [4] Dithiobis(succinimidyl propionate) modified gold microarray electrode based electrochemical immunosensor for ultrasensitive detection of cortisol
    Arya, Sunil K.
    Chornokur, Ganna
    Venugopal, Manju
    Bhansali, Shekhar
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 25 (10) : 2296 - 2301
  • [5] Atkins P.W., 2001, PHYS CHEM, P827
  • [6] Mixed self-assembled monolayer (mSAM) based impedimetric immunosensors for cardiac troponin I (cTnI) and soluble lectin-like oxidized low-density lipoprotein receptor-1 (sLOX-1)
    Billah, Md Morsaline
    Hays, Henry C. W.
    Hodges, Christopher S.
    Ponnambalam, Sreenivasan
    Vohra, Ravi
    Millner, Paul A.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 361 - 366
  • [7] Flexible Label-Free Quantitative Assay for Antibodies to Influenza Virus Hemagglutinins
    Carney, Paul J.
    Lipatov, Aleksandr S.
    Monto, Arnold S.
    Donis, Ruben O.
    Stevens, James
    [J]. CLINICAL AND VACCINE IMMUNOLOGY, 2010, 17 (09) : 1407 - 1416
  • [8] Use of a heterodimeric coiled-coil system for biosensor application and affinity purification
    Chao, HM
    Bautista, DL
    Litowski, J
    Irvin, RT
    Hodges, RS
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 715 (01): : 307 - 329
  • [9] Electrochemical immunosensor for simultaneous detection of multiplex cancer biomarkers based on graphene nanocomposites
    Chen, Xia
    Jia, Xinle
    Han, Jingman
    Ma, Jie
    Ma, Zhanfang
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 50 : 356 - 361
  • [10] Cocklin S., 2005, PROTEIN PROTEIN INTE