With a novel evaluation method comparison of 2 homogeneous assay kits for high density lipoprotein cholesterol

被引:4
作者
Kurosaki, Yoshifumi [1 ]
Hachimura, Kazuo [2 ]
Ogawa, Zensuke [1 ]
机构
[1] Kitasato Univ, Grad Sch Med Sci, Dept Mol Med Biol, Kanagawa, NA 2288555, Japan
[2] Kitasato Univ, Sch Allied Hlth Sci, Dept Clin Chem, Kanagawa, NA 2288555, Japan
关键词
Cholesterol; Gel-filtration; HDL; Homogeneous; HPLC; HDL-CHOLESTEROL; PRECIPITATION; ULTRACENTRIFUGATION; QUANTIFICATION; TRIGLYCERIDES; PERFORMANCE; SERUM; HPLC;
D O I
10.1016/j.cca.2008.11.026
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: 2 homogeneous assay kits, Determiner L HDL-C from Kyowa Medex, Co., Ltd. (Tokyo, Japan) (KWM) and Cholestest NHDL from Daiichi Pure Chemical, Co., Ltd. (Tokyo, Japan) (DIC), for HDL-C are widely used in laboratory tests worldwide. Meanwhile, it was reported that free cholesterol (FC) in HDL is not measured with one of these kits. We devised a novel evaluation method and analyzed the 2 kits in detail. Methods: Using HPLC, the residual amounts of cholesterol in reaction mixtures were compared before and after reaction with homogeneous reagents. Healthy sera were reacted with homogeneous reagents or with heated, non-enzyme reagents from each kit. The FC and total cholesterol in each lipoprotein were continuously measured with HPLC. Results: With KWM, the HDL-C was measured >95%. With DIC, all FC in sera was eliminated in the first reaction, and FC in HDL was not measured. Moreover, the peak X that was assumed to be a part of HDL was separated with DIC, and the cholesterol in the peak X was not measured. Conclusions: 2 HDL-C assay kits were compared using a novel evaluation method. KWM was good overall. DIC was found to have 2 problems: 1) FC in HDL was not measured, and 2) the cholesterol in peak X that was assumed to be a part of HDL was not measured. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:110 / 113
页数:4
相关论文
共 14 条
  • [1] ABELL LL, 1952, J BIOL CHEM, V195, P357
  • [2] Arranz-Peña ML, 1998, CLIN CHEM, V44, P2499
  • [3] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF HUMAN-SERUM LIPOPROTEINS - SELECTIVE DETECTION OF TRIGLYCERIDES BY ENZYMATIC-REACTION
    HARA, I
    SHIRAISHI, K
    OKAZAKI, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1982, 239 (APR): : 549 - 557
  • [4] HIRAI N, 2006, JPN J MED TEC, V55, P202
  • [5] Huang YC, 1997, CLIN CHEM, V43, P1048
  • [6] Izawa S, 1997, J MED PHARM SCI, V37, P1385
  • [7] Kimberly MM, 1999, CLIN CHEM, V45, P1803
  • [8] NEMA T, 1996, J ANAL BIOSCI, V19, P350
  • [9] Okazaki M, 1997, CLIN CHEM, V43, P1885
  • [10] SUGIUCHI H, 1995, CLIN CHEM, V41, P717