Extravasated Contrast Material in Penetrating Abdominopelvic Trauma: Dual-Contrast Dual-Energy CT for Improved Diagnosis-Preliminary Results in an Animal Model

被引:37
作者
Mongan, John [1 ]
Rathnayake, Samira [1 ]
Fu, Yanjun [1 ]
Gao, Dong-Wei [1 ]
Yeh, Benjamin M. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
基金
美国国家卫生研究院;
关键词
TORSO TRAUMA; IODINE; BISMUTH; INJURY;
D O I
10.1148/radiol.13121267
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the diagnostic performance of dual-energy (DE) computed tomography (CT) with two simultaneously administered contrast agents (hereafter, dual contrast) with that of conventional CT in the evaluation of the presence and source of extravasation in penetrating abdominopelvic trauma. Materials and Methods: Institutional animal care and use committee approval was obtained, and the study was performed in accordance with National Institutes of Health guidelines for the care and use of laboratory animals. Five rabbits with bowel trauma, vascular penetrating trauma, or both were imaged with simultaneous iodinated intravenous and bismuth subsalicylate enteric contrast material at DE CT. Four attending radiologists and six radiology residents without prior DE CT experience each evaluated 10 extraluminal collections to identify the vascular and/or enteric origin of extravasation and assess their level of diagnostic confidence, first with virtual monochromatic images simulating conventional CT and then with DE CT material decomposition attenuation maps. Results: Overall accuracy of identification of source of extravasation increased from 78% with conventional CT to 92% with DE CT (157 of 200 diagnoses vs 184 of 200 diagnoses, respectively; P < .001). Nine radiologists were more accurate with DE CT; one had no change. Mean confidence increased from 67% to 81% with DE CT (P < .001). Conclusion: In a rabbit abdominopelvic trauma model, dual-contrast DE CT significantly increased accuracy and confidence in the diagnosis of vascular versus enteric extravasated contrast material. (C) RSNA, 2013
引用
收藏
页码:738 / 742
页数:5
相关论文
共 4 条
  • [1] Quantitative accuracy and dose efficiency of dual-contrast imaging using dual-energy CT: a phantom study
    Ren, Liqiang
    Rajendran, Kishore
    McCollough, Cynthia H.
    Yu, Lifeng
    MEDICAL PHYSICS, 2020, 47 (02) : 441 - 456
  • [2] Can Dual-energy CT Evaluate Contrast Enhancement of Ground-glass Attenuation? Phantom and Preliminary Clinical Studies
    Kawai, Tatsuya
    Shibamoto, Yuta
    Hara, Masaki
    Arakawa, Toshinao
    Nagai, Keiichi
    Ohashi, Kazuya
    ACADEMIC RADIOLOGY, 2011, 18 (06) : 682 - 689
  • [3] Improved Calcium Scoring at Dual-Energy Computed Tomography Angiography Using a High-Z Contrast Element and Novel Material Separation Technique
    Lambert, Jack W.
    Sun, Yuxin
    Ordovas, Karen G.
    Gould, Robert G.
    Wang, Sizhe
    Yeh, Benjamin M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (03) : 459 - 466
  • [4] Characterization of Small Incidental Indeterminate Hypoattenuating Hepatic Lesions: Added Value of Single-Phase Contrast-Enhanced Dual-Energy CT Material Attenuation Analysis
    Patel, Bhavik N.
    Rosenberg, Michael
    Vernuccio, Federica
    Ramirez-Giraldo, Juan Carlos
    Nelson, Rendon
    Farjat, Alfredo
    Marin, Daniele
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (03) : 571 - 579