Evaluation of the Dislodgement Resistance of a New Pozzolan-Based Cement (EndoSeal MTA) Compared to ProRoot MTA and Biodentine in the Presence and Absence of Blood

被引:9
作者
Adl, Alireza [1 ]
Shojaee, Nooshin Sadat [2 ]
Pourhatami, Negar [3 ]
机构
[1] Shiraz Univ Med Sci, Biomat Res Ctr, Sch Dent, Dept Endodont, Shiraz, Iran
[2] Shiraz Univ Med Sci, Sch Dent, Dept Endodont, Shiraz, Iran
[3] Shiraz Univ Med Sci, Sch Dent, Dept Endodont, Endodont, Shiraz, Iran
关键词
Contamination - Blood - Bond strength (materials) - Pozzolan - Repair - Testing - Calcium silicate;
D O I
10.1155/2019/3863069
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Introduction. This in vitro study investigated the dislodgement resistance of EndoSeal MTA, a new pozzolan-containing calcium silicate-based material, in comparison with ProRoot MTA and Biodentine in the presence and absence of contamination with blood. Methods. Standard furcal perforations were created in 180 human mandibular first molars. The teeth were randomly allocated to 12 groups of 15 each. ProRoot MTA, Biodentine, and EndoSeal MTA were used to repair the perforations. In half of the samples, the walls of the perforated areas were contaminated with blood, whereas saline was injected into the other half. A push-out test was performed using a universal testing machine after 24 hours or 7 days. To evaluate failure patterns, the samples were split into half and were examined under a stereomicroscope at a 20x magnification. Data were analyzed using three-way analysis of variance, Tukey test, and Student's t-test. Results. At both time intervals and in the presence and absence of contamination with blood, ProRoot MTA and Biodentine had significantly higher retention values than EndoSeal MTA (p<0.001). Contamination with blood had no effect on EndoSeal MTA; however, it negatively affected the dislodgement resistance of Biodentine at 24 hours and ProRoot MTA at both time intervals (p<0.05). Time significantly affected only the bond strength of the uncontaminated groups (p>0.001). The most common type of failure was mixed for ProRoot MTA and Biodentine, whereas it was cohesive for EndoSeal MTA. Conclusions. ProRoot MTA and Biodentine showed higher values of bond strength than EndoSeal MTA and may thus be better options for the repair of root perforations.
引用
收藏
页数:6
相关论文
共 41 条
  • [1] Aggarwal Vivek, 2013, J Conserv Dent, V16, P462, DOI 10.4103/0972-0707.117504
  • [2] Akcay Huseyin, 2016, Eur J Dent, V10, P370, DOI 10.4103/1305-7456.184150
  • [3] Ashofteh Yazdi Kazem, 2017, Iran Endod J, V12, P196, DOI 10.22037/iej.2017.38
  • [4] Butt Naziya, 2014, Indian J Dent Res, V25, P692, DOI 10.4103/0970-9290.152163
  • [5] Mineral trioxide aggregate: a review of the constituents and biological properties of the material
    Camilleri, J.
    Ford, T. R. Pitt
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (10) : 747 - 754
  • [6] Resistance of Hydraulic Calcium Silicate Cements to Dislodgment in Short- and Long-term Assessment
    De-Deuse, Gustavo
    Ferreira, Caroline Baptista
    Oliveira, Diogo da Silva
    de Queiroz, Thais Fernandes
    Souza, Erick Miranda
    Depes de Gouvea, Cresus Vinicius
    Nogueira Leal Silva, Emmanuel Joao
    [J]. JOURNAL OF ADHESIVE DENTISTRY, 2016, 18 (02) : 157 - 160
  • [7] FARZANEH M, 2002, JOURNAL, V30, P627, DOI DOI 10.1097/01.DON.0000129958.12388.82
  • [8] D90: The Strongest Contributor to Setting Time in Mineral Trioxide Aggregate and Portland Cement
    Ha, William N.
    Bentz, Dale P.
    Kahler, Bill
    Walsh, Laurence J.
    [J]. JOURNAL OF ENDODONTICS, 2015, 41 (07) : 1146 - 1150
  • [9] Evaluation of calcium-releasing and apatite-forming abilities of fast-setting calcium silicate-based endodontic materials
    Han, L.
    Kodama, S.
    Okiji, T.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (02) : 124 - 130
  • [10] Comparison of Bacterial Leakage Resistance of Various Root Canal Filling Materials and Methods: Confocal Laser-Scanning Microscope Study
    Hwang, Ji Hee
    Chung, Jin
    Na, Hee-Sam
    Park, Eunjoo
    Kwak, Sangwon
    Kim, Hyeon-Cheol
    [J]. SCANNING, 2015, 37 (06) : 422 - 428