The performance of solar PV modules with two glass types after 11 years of outdoor exposure under the mediterranean climatic conditions

被引:16
|
作者
Belhaouas, N. [1 ]
Mehareb, F. [1 ]
Kouadri-Boudjelthia, E. [1 ]
Assem, H. [1 ]
Bensalem, S. [1 ]
Hadjrioua, F. [1 ]
Aissaoui, A. [1 ]
Hafdaoui, H. [1 ]
Chahtou, A. [1 ]
Bakria, K. [1 ]
Saheb-Koussa, D. [1 ]
机构
[1] CDER, BP 62,Route Observ, Algiers 16340, Algeria
关键词
Photovoltaic (PV) modules; Float and textured PV modules glass types; PV modules performance; PV aging degradation; PV module failures; Outdoor testing; IEC61215; Mediterranean climatic condition; SILICON PHOTOVOLTAIC MODULES; DEGRADATION ANALYSIS; SNAIL TRAILS; POWER; TECHNOLOGIES;
D O I
10.1016/j.seta.2021.101771
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents an analysis, assessment, and investigation of the degradation performance of the monocrystalline silicon PV modules with two glass types (Float, Textured) exposed outdoor for eleven years under Mediterranean climate conditions in northern Algeria, Bouzareah city, Algeria. In this regard, several protocol tests, experimental and measurement procedures have been developed according to IEC 61215-2 requirements in order to inspect the performance of deployed PV modules by considering their glass types. Where, they have been the subject of several PV inspections such as visual, electrical, PV characterization, and temperature coefficients and thermographic ...etc. The inspections, classifications, and statistical analysis results reveal that the deployed PV modules with two glass types suffer mainly from optical failure occurrences. The measured electrical PV parameters (P-max, I-sc, V-oc and FF) of the deployed PV modules have been reduced with annual degradation (1.04%/year, 0.5%/year, 0.3%/year, and 1.04 %/year). In the same way, the temperature coefficients have been influenced by the PV modules degradations as well. Besides, some of the deployed PV modules characteristic curves suffered from inflex point's exhibition. The thermal inspections show that the deployed PV modules regardless of their glass types caused by the inhomogeneity distribution of the optical failures are significantly affected by minor temperature mismatch. This paper investigates and discusses as well several correlation proposals between the presented PV inspections by considering multiple impacts between these inspections and the performance of the deployed PV modules with their two glass types in view to better understand the PV module degradation.
引用
收藏
页数:16
相关论文
共 5 条
  • [1] Experimental investigation of observed defects in crystalline silicon PV modules under outdoor hot dry climatic conditions in Algeria
    Bouraiou, Ahmed
    Hamouda, Messaoud
    Chaker, Abdelkader
    Necaibia, Ammar
    Mostefaoui, Mohammed
    Boutasseta, Nadir
    Ziane, Abderrezzaq
    Dabou, Rachid
    Sahouane, Nordine
    Lachtar, Salah
    SOLAR ENERGY, 2018, 159 : 475 - 487
  • [2] Performance analysis of PV panels based on different technologies after two years of outdoor exposure in Fukushima, Japan
    Ustun, Taha Selim
    Nakamura, Yasuhiro
    Hashimoto, Jun
    Otani, Kenji
    RENEWABLE ENERGY, 2019, 136 : 159 - 178
  • [3] Artificial intelligence technique for estimating PV modules performance ratio under outdoor operating conditions
    Tossa, Alain K.
    Soro, Y. M.
    Coulibaly, Y.
    Azoumah, Y.
    Migan-Dubois, Anne
    Thiaw, L.
    Lishou, Claude
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2018, 10 (05)
  • [4] Analysis of long-term performance and reliability of PV modules under tropical climatic conditions in sub-Saharan
    Atsu, Divine
    Seres, Istvan
    Aghaei, Mohammadreza
    Farkas, Istvan
    RENEWABLE ENERGY, 2020, 162 : 285 - 295
  • [5] Performance comparison of mono and polycrystalline silicon solar photovoltaic modules under tropical wet and dry climatic conditions in east-central India
    Baghel, Niranjan Singh
    Chander, Nikhil
    CLEAN ENERGY, 2022, 6 (01): : 929 - 941