Interest of positron-emission tomography and magnetic resonance imaging for radiotherapy planning and control

被引:10
作者
Crehange, G. [1 ]
Soussan, M. [2 ]
Gensanne, D. [3 ,4 ]
Decazes, P. [4 ,5 ]
Thariat, J. [6 ,7 ,8 ,9 ]
Thureau, S. [3 ,4 ,5 ,9 ]
机构
[1] Inst Curie, Dept Radiotherapie Oncol, 26 Rue Ulm, F-75005 Paris, France
[2] Hop Univ, Hop Avicenne, AP HP, Serv Med Nucl, 125 Rue Stalingrad, F-93000 Bobigny, France
[3] Ctr Henri Becquerel, Dept Radiotherapie & Phys Med, 1 Rue Amiens, F-76038 Rouen, France
[4] Univ Rouen Normandie, Quantif Litis EA4108, Rue Amiens, F-76000 Rouen, France
[5] Ctr Henri Becquerel, Dept Imagerie Med Nucl, 1 Rue Amiens, F-76038 Rouen, France
[6] Ctr Francois Baclesse, Dept Oncoradiotherapie, 3 Ave Gen Harris, F-14000 Caen, France
[7] Assoc Adv Resource Ctr Hadrontherapy Europe Archa, 3 Ave Gen Harris, F-14000 Caen, France
[8] Univ Caen Normandie Unicaen, 3 Ave Gen Harris, F-14000 Caen, France
[9] Inst Natl Phys Nucl & Phys Particules IN2P3, Lab Phys Corpusculaire, 6 Blvd Marechal Juin, F-14000 Caen, France
来源
CANCER RADIOTHERAPIE | 2020年 / 24卷 / 05期
关键词
PET; Radiotherapy; MRI; PET/MRI; MRI linac; GUIDED RADIATION-THERAPY; PET/MRI; MOTION;
D O I
10.1016/j.canrad.2020.02.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Computed tomography (CT) in the treatment position is currently indispensable for planning radiation therapy. Other imaging modalities, such as magnetic resonance imaging (MRI) and positron emission-tomography (PET), can be used to improve the definition of the tumour and/or healthy tissue but also to provide functional data of the target volume. Accurate image registration is essential for treatment planning, so MRI and PET scans should be registered at the planning CT scan. Hybrid PET/MRI scans with a hard plane can be used but pose the problem of the absence of CT scans. Finally, techniques for moving the patient on a rigid air-cushioned table allow PET/CT/MRI scans to be performed in the treatment position while limiting the patient's movements exist. At the same time, the advent of MRI-linear accelerator systems allows to redefine image-guided radiotherapy and to propose treatments with daily recalculation of the dose. The place of PET during treatment remains more confidential and currently only in research and prototype status. The same development of imaging during radiotherapy is underway in proton therapy. (C) 2020 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:398 / 402
页数:5
相关论文
共 50 条
[21]   Utility of positron-emission tomography/computed tomography imaging in the management of the neck in recurrent laryngeal cancer [J].
Gilbert, Mark R. ;
Branstetter, Barton F. ;
Kim, Seungwon .
LARYNGOSCOPE, 2012, 122 (04) :821-825
[22]   Positron Emission Tomography/Magnetic Resonance Imaging Radiomics in Predicting Lung Adenocarcinoma and Squamous Cell Carcinoma [J].
Tang, Xin ;
Liang, Jiangtao ;
Xiang, Bolin ;
Yuan, Changfeng ;
Wang, Luoyu ;
Zhu, Bin ;
Ge, Xiuhong ;
Fang, Min ;
Ding, Zhongxiang .
FRONTIERS IN ONCOLOGY, 2022, 12
[23]   Recent Advances in Positron Emission Tomography/Magnetic Resonance Imaging Technology [J].
Arabi, Hossein ;
Zaidi, Habib .
MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2023, 31 (04) :503-515
[25]   Positron emission tomography-magnetic resonance imaging as a research tool in musculoskeletal conditions [J].
van den Wyngaert, Tim ;
de Schepper, Stijn ;
Elvas, Filipe ;
Seyedinia, Seyedeh S. ;
Beheshti, Mohsen .
QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 66 (01) :15-30
[26]   A Baboon Brain Atlas for Magnetic Resonance Imaging and Positron Emission Tomography Image Analysis [J].
Agaronyan, Artur ;
Syed, Raeyan ;
Kim, Ryan ;
Hsu, Chao-Hsiung ;
Love, Scott A. ;
Hooker, Jacob M. ;
Reid, Alicia E. ;
Wang, Paul C. ;
Ishibashi, Nobuyuki ;
Kang, Yeona ;
Tu, Tsang-Wei .
FRONTIERS IN NEUROANATOMY, 2022, 15
[27]   Positron emission mammography in breast cancer presurgical planning: comparisons with magnetic resonance imaging [J].
Schilling, Kathy ;
Narayanan, Deepa ;
Kalinyak, Judith E. ;
The, Juliette ;
Velasquez, Maria Victoria ;
Kahn, Simone ;
Saady, Matthew ;
Mahal, Ravinder ;
Chrystal, Larraine .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (01) :23-36
[28]   Robustness and Generalizability of Deep Learning Synthetic Computed Tomography for Positron Emission Tomography/Magnetic Resonance Imaging -Based Radiation Therapy Planning of Patients With Head and Neck Cancer [J].
Olin, Anders B. ;
Thomas, Christopher ;
Hansen, Adam E. ;
Rasmussen, Jacob H. ;
Krokos, Georgios ;
Urbano, Teresa Guerrero ;
Michaelidou, Andriana ;
Jakoby, Bjoern ;
Ladefoged, Claes N. ;
Berthelsen, Anne K. ;
Hakansson, Katrin ;
Vogelius, Ivan R. ;
Specht, Lena ;
Barrington, Sally F. ;
Andersen, Flemming L. ;
Fischer, Barbara M. .
ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (06)
[29]   Diagnostic performance of fluorodeoxyglucose positron emission tomography/magnetic resonance imaging fusion images of gynecological malignant tumors: comparison with positron emission tomography/computed tomography [J].
Kazuya Nakajo ;
Mitsuaki Tatsumi ;
Atsuo Inoue ;
Kayako Isohashi ;
Ichiro Higuchi ;
Hiroki Kato ;
Masao Imaizumi ;
Takayuki Enomoto ;
Eku Shimosegawa ;
Tadashi Kimura ;
Jun Hatazawa .
Japanese Journal of Radiology, 2010, 28 :95-100
[30]   MAGNETIC RESONANCE IMAGING IN POSTPROSTATECTOMY RADIOTHERAPY PLANNING [J].
Sefrova, Jana ;
Odrazka, Karel ;
Paluska, Petr ;
Belobradek, Zdenek ;
Brodak, Milos ;
Dolezel, Martin ;
Prosvic, Petr ;
Macingova, Zuzana ;
Vosmik, Milan ;
Hoffmann, Petr ;
Louda, Miroslav ;
Nejedla, Anna .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (02) :911-918