Small-scale test and analysis of corrugated-steel-plate--concrete composite member adopting novel shear connectors

被引:15
作者
Zhang, Ji-lei [1 ]
Liu, Bao-dong [1 ]
Zhang, Peng-yuan [1 ]
Wang, Zhi-hong [2 ]
机构
[1] Beijing Jiaotong Univ, Sch Civil Engn & Architecture, Beijing 100044, Peoples R China
[2] Hengshui Yitong Pipe Ind Co Ltd, Hengshui 053000, Peoples R China
关键词
Corrugated steel plate; Composite member; Small-scale test; Novel shear connector; Finite element analysis; Shear resistance; Parametric analysis; STUD; BEHAVIOR; PERFORMANCE; TROUGHS; RULES; FULL;
D O I
10.1016/j.engstruct.2019.01.115
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Research on the co-working behaviour of a corrugated steel plate with a sinusoidal cross section and concrete has rarely been published. Despite the fact that the conventionally used concrete trapezoidal-cross-sectional metal sheet composite slab has been widely investigated and exhibits several geometrical similarities with the corrugated-steel-plate-concrete (CSPC) composite slab, a significant difference exists in the co-working behaviour, requiring detailed study. Substantial research work is necessary before the CSPC composite member can be employed in the construction of buried culverts as expected, as an alternative to concrete and metal culverts. In this study, a newly proposed small-scale push test was conducted to investigate the longitudinal shear behaviour of CSPC composite members. Specimens with conventional stud shear connectors and newly designed inverted umbrella connectors were tested to validate the effects of the connector shank diameter, shank length and spacing on the shear behaviour and resistance of the two connector types. The lower-than-expected test results of shear resistance and slip capacity were discussed compared with the results from analytical methods and optimized numerical models. Finite element models were constructed in the ABAQUS software to verify the feasibility of nonlinear finite element method analysis on CSPC composite members. Optimisation suggestions for the small-scale test were finally proposed concerning other factors such as the support condition, significantly greater shank length and concrete thickness.
引用
收藏
页码:369 / 383
页数:15
相关论文
共 35 条
  • [1] Abaqus, 2014, AB VERS 6 14
  • [2] 3D finite-element analysis of shear connectors with partial interaction
    Abbu, Muthanna
    Ekmekyapar, Talha
    Ozakca, Mustafa
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2016, 169 (02) : 96 - 107
  • [3] Abdullah R., 2004, Experimental evaluation and analytical modeling of shear bond in composite slabs
  • [4] [Anonymous], 2017, GB500172017
  • [5] [Anonymous], 2002, GB500102002 MIN HOUS
  • [6] Rib shear connectors in composite profiled slabs
    Burnet, MJ
    Oehlers, DJ
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (12) : 1267 - 1287
  • [7] CEN, 2004, EUR 4 DES COMP STE 1
  • [8] Finite element modeling of debonding failures in FRP-strengthened RC beams: A dynamic approach
    Chen, G. M.
    Teng, J. G.
    Chen, J. F.
    Xiao, Q. G.
    [J]. COMPUTERS & STRUCTURES, 2015, 158 : 167 - 183
  • [9] Experimental investigation and design of corroded stud shear connectors
    Chen, Ju
    Zhao, Yu-xi
    Wu, Lin
    Jin, Wei-liang
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2016, 19 (02) : 218 - 226
  • [10] COMPOSITE SLAB BEHAVIOR AND STRENGTH ANALYSIS .1. CALCULATION PROCEDURE
    DANIELS, BJ
    CRISINEL, M
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1993, 119 (01): : 16 - 35