Analyzing the Amperometric Response of a Glucose Oxidase Sensor Applying Mathematical Models

被引:1
作者
Gonzalez Navarro, Felix F. [1 ]
Stoytcheva, Margarita [1 ]
BelancheMunoz, Lluis A. [2 ]
Flores Rios, Brenda L. [1 ]
Ibarra Esquer, Jorge E. [1 ]
Renteria Gutierrez, Livier [1 ]
Lopez Morteo, Gabriel A. [1 ]
机构
[1] Univ Autonoma Baja California, Inst Ingn, Mexicali, Baja California, Mexico
[2] Univ Politecn Cataluna, Dept Ciencies Computacio, Barcelona, Spain
关键词
Glucose oxidase amperometric sensor; machine learning; regression models; biosensor modeling; BIOSENSORS;
D O I
10.2174/1573411012999160401125518
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: The biosensors are analytical devices combining a bioreceptor and a physicochemical transducer to translate the signal resulting from the interaction of the analyte with the biological element into an electrical reading. The technological attractiveness of the biosensors resides in their high sensitivity, continuous measuring capabilities, low cost, and precision. An important and promising area of biosensors application is the associated with blood glucose levels monitoring in diabetic patients. However, accuracy and stability issues are still under development, impeding the more widespread offering of glucose biosensors in the market. Thus, this work aims to contribute to the biosensors technology by analyzing the amperometric response to glucose of a typical glucose oxidase-based sensor of second generation, applying mathematical models. Methods: The amperometric response of the glucose oxidase-based electrochemical sensor of second generation was analyzed under different conditions such as temperature, pH, mediators' and substrate's concentrations through statistical learning methods from a regression perspective. Artificial Neural Networks (ANN), LASSO and RIDGE Regression and Classification and Regression (CART) were the algorithms selected to achieve the regression task. Results: The reported experimental results show a promising very low prediction error of the biosensor output by using Neural Networks and Classification and Regression Trees. It is also shown that the relationship between predictors, i.e. features or variables- and response-target variable-corresponds to a non-linear behavior. Conclusion: A final CART and a Neural Network models are presented as a simple solutions that can be solidly constructed in order to predict the amperometric response of a glucose oxidase sensor. The experimental proposal and conditions offered in this paper could be applied for other scenarios in the wide spectrum of biosensing technology.
引用
收藏
页码:634 / 641
页数:8
相关论文
共 50 条
[31]   Amperometric biosensors based on carbon paste electrodes modified with nanostructured mixed-valence manganese oxides and glucose oxidase [J].
Cui, Xiaoli ;
Liu, Guodong ;
Lin, Yuehe .
NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2005, 1 (02) :130-135
[32]   Non-enzymatic Amperometric Glucose Sensor Based on Copper Nanowires Decorated Reduced Graphene Oxide [J].
Ju, Lele ;
Wu, Guosong ;
Lu, Biao ;
Li, Xiaoyun ;
Wu, Huaping ;
Liu, Aiping .
ELECTROANALYSIS, 2016, 28 (10) :2543-2551
[33]   Highly-branched dendrite cuprous oxide films for non-enzymatic amperometric glucose sensor [J].
Sun, Fang ;
Wang, Zichen .
MATERIALS LETTERS, 2019, 234 :62-65
[34]   Inhibition and Activation of Glucose Oxidase Bioanodes for Use in a Self-Powered EDTA Sensor [J].
Meredith, Matthew T. ;
Minteer, Shelley D. .
ANALYTICAL CHEMISTRY, 2011, 83 (13) :5436-5441
[35]   Microfluidic devices and true-color sensor as platform for glucose oxidase and laccase assays [J].
Demirkol, Dilek Odaci ;
Dornbusch, Kay ;
Feller, Karl-Heinz ;
Timur, Suna .
ENGINEERING IN LIFE SCIENCES, 2011, 11 (02) :182-188
[36]   Bimetallic PdCu nanoparticle decorated three-dimensional graphene hydrogel for non-enzymatic amperometric glucose sensor [J].
Yuan, Ming ;
Liu, Aiping ;
Zhao, Ming ;
Dong, Wenjun ;
Zhao, Tingyu ;
Wang, Jiajun ;
Tang, Weihua .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 :707-714
[37]   Amperometric glucose sensing with polyaniline/poly(acrylic acid) composite film bearing covalently-immobilized glucose oxidase: A novel method combining enzymatic glucose oxidation and cathodic O2 reduction [J].
Homma, Toshimasa ;
Sumita, Daiki ;
Kondo, Mizuki ;
Kuwahara, Takashi ;
Shimomura, Masato .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 712 :119-123
[38]   Analyzing the effectiveness of MEMS sensor and IoT in predicting wave height using machine learning models [J].
Mishra, Jai Prakash ;
Singh, Kulwant ;
Chaudhary, Himanshu .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (07)
[39]   Amperometric glucose sensor based on 3D ordered nickel-palladium nanomaterial supported by silicon MCP array [J].
Miao, Fengjuan ;
Tao, Bairui ;
Sun, Li ;
Liu, Tao ;
You, Jinchuan ;
Wang, Lianwei ;
Chu, Paul K. .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (01) :338-342
[40]   Glucose sensor based on nanostructured carbon electrode with immobilized PQQ-containing glucose dehydrogenase: Construction, experimental study and mathematical modeling [J].
Puida, Mantas ;
Dabulyte-Bagdonaviciene, Jurgita ;
Ivanauskas, Feliksas ;
Razumas, Valdemaras ;
Razumiene, Julija ;
Sakinyte, Ieva .
NONLINEAR ANALYSIS-MODELLING AND CONTROL, 2016, 21 (05) :702-715