Earth fault location based on evaluation of voltage sag at secondary side of medium voltage/low voltage transformers

被引:29
|
作者
Topolanek, David [1 ]
Lehtonen, Matti [2 ]
Adzman, Mohd Rafi [2 ]
Toman, Petr [1 ]
机构
[1] Brno Univ Technol, Fac Elect Engn & Commun, CS-61090 Brno, Czech Republic
[2] Aalto Univ, Sch Sci & Technol, Dept Elect Engn, Aalto, Finland
关键词
earthing; fault location; power transformers; transformer substations; power supply quality; smart power grids; synchronisation; power meters; voltage sag evaluation; medium voltage-low voltage transformers; secondary side transformers; power quality meters; distribution transformer substations; power quality monitoring; electrical network global evolution; smart grid; earth fault localisation; compensated neutral distribution networks; auxiliary resistor; fault current; numerical model;
D O I
10.1049/iet-gtd.2014.0460
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The main reasons for installation of power quality meters in distribution transformer substations are power quality monitoring and global evolution of electrical network towards the smart grid'. In case that all measurements from the meters are properly synchronised and centralised, new possibilities of control or evaluation of the network are enabled. This contribution proposes the possibility for an earth fault localisation with the aid of synchronised data recorded on the low-voltage side of the medium voltage/low voltage transformers in compensated neutral distribution networks which are equipped with auxiliary resistor for short-time increasing of the active part of the fault current. The described method uses voltage sags evoked by connecting of the auxiliary resistor for locating the faulty section. The proposed method is tested with the help of numerical model which presents a part of the distribution network.
引用
收藏
页码:2069 / 2077
页数:9
相关论文
共 50 条
  • [21] VARIABLE VOLTAGE TRANSFORMERS FOR MEDIUM VOLTAGE HEATER CONTROL
    Cardinal, Paul G.
    Burns, David
    Sauer, Daniel
    2016 Petroleum and Chemical Industry Technical Conference (PCIC), 2016,
  • [22] Elimination of secondary loop voltage drops in voltage transformers
    Department of Electrical Engineering and Applied Electronic Technology, Tsinghua University, Beijing 100084, China
    Qinghua Daxue Xuebao, 2006, 4 (457-459):
  • [23] Evaluation of Fault Location Based on Voltage Sags Profiles: a Study on the Influence of Voltage Sags Patterns
    Mokhlis, H.
    Mohamad, Hasmaini
    Bakar, A. H. A.
    Li, H. Y.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2011, 6 (02): : 874 - 880
  • [24] Fault location in high-voltage direct-current grids based on panoramic voltage features and vision transformers
    Ren, Bo
    Luo, Yongjie
    Zhou, Niancheng
    Wang, Qianggang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 158
  • [25] Research on Step Voltage of Medium Voltage Shore Power System Near Fault Location
    Yang Feng
    Luo Ningzhao
    Huang Jing
    Wu Benxiang
    2015 IEEE ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC), 2015, : 1005 - 1009
  • [26] Research of Voltage Sag Propagation through Transformers
    Li Xinian
    Wang Yanwen
    MECHATRONICS AND INTELLIGENT MATERIALS III, PTS 1-3, 2013, 706-708 : 1504 - 1510
  • [27] Over-Voltage Transients in the Secondary Side of EAF Transformers
    Cardoso, Marcelo Murta G.
    AISTECH 2013: PROCEEDINGS OF THE IRON & STEEL TECHNOLOGY CONFERENCE, VOLS I AND II, 2013, : 2527 - 2538
  • [28] Voltage Sag Source Location Based on Pattern Recognition
    Lv, Ganyun
    Sun, Weimen
    JOURNAL OF ENERGY ENGINEERING, 2013, 139 (02) : 136 - 141
  • [29] FAULT LOCATION IN LOW-VOLTAGE SYSTEM
    RIETZ, W
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1971, 23 (20): : 486 - &
  • [30] A Voltage Sag Severity Evaluation Method for the System Side Which Considers the Influence of the Voltage Tolerance Curve and Sag Type
    Xu, Yonghai
    Fan, Xingguan
    Deng, Siying
    Niu, Chunhao
    ENERGIES, 2021, 14 (16)