Improvement of dose distribution in breast radiotherapy using a reversible transverse magnetic field Linac-MR unit

被引:11
作者
Esmaeeli, A. D. [1 ]
Mahdavi, S. R. [2 ]
Pouladian, M. [3 ]
Monfared, A. S. [4 ]
Bagheri, S. [3 ]
机构
[1] Islamic Azad Univ, Dept Phys, Rasht Branch, Rasht 4147654919, Iran
[2] Univ Tehran Med Sci, Dept Med Phys, Tehran 14174, Iran
[3] Islamic Azad Univ, Dept Med Radiat Engn, Sci & Res Branch, Tehran 1477893855, Iran
[4] Babol Univ Med Sci, Dept Med Phys, Babol Sar 4714871167, Iran
关键词
electron return effect; magnetic field; breast radiotherapy; GEANT4; REDUCING SCATTER RADIATION; CONTRALATERAL BREAST; LUNG-CANCER; BEAM; ACCELERATOR; ELECTRON; IRRADIATION; MORTALITY; DOSIMETRY; IMPACT;
D O I
10.1118/1.4845175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the improvement in dose distribution in tangential breast radiotherapy using a reversible transverse magnetic field that maintains the same direction of Lorentz force between two fields. The investigation has a potential application in future Linac-MR units. Methods: Computed tomography images of four patients and magnetic fields of 0.25-1.5 Tesla (T) were used for Monte Carlo simulation. Two patients had intact breast while the other two had mastectomy. Simulations of planning and chest wall irradiation were similar to the actual clinical process. The direction of superior-inferior magnetic field for the medial treatment beam was reversed for the lateral beam. Results: For the ipsilateral lung and heart mean doses were reduced by a mean (range) of 45.8% (27.6%-58.6%) and 26.0% (20.2%-38.9%), respectively, depending on various treatment plan setups. The mean V-20 for ipsilateral lung was reduced by 55.0% (43.6%-77.3%). In addition acceptable results were shown after simulation of 0.25 T magnetic field demonstrated in dose-volume reductions of the heart, ipsilateral lung, and noninvolved skin. Conclusions: Applying a reversible magnetic field during breast radiotherapy, not only reduces the dose to the lung and heart but also produces a sharp drop dose volume histogram for planning target volume, because of bending of the path of secondary charged particles toward the chest wall by the Lorentz force. The simulations have shown that use of the magnetic field at 1.5 T is not feasible for clinical applications due to the increase of ipsilateral chest wall skin dose in comparison to the conventional planning while 0.25 T is suitable for all patients due to dose reduction to the chest wall skin. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:11
相关论文
共 44 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Assessing the impact of screening mammography: breast cancer incidence and mortality rates in Connecticut (1943-2002) [J].
Anderson, William F. ;
Jatoi, Ismail ;
Devesa, Susan S. .
BREAST CANCER RESEARCH AND TREATMENT, 2006, 99 (03) :333-340
[3]   Evaluation of skin dose associated with different frequencies of bolus applications in post-mastectomy three-dimensional conformal radiotherapy [J].
Andic, Fundagul ;
Ors, Yasemin ;
Davutoglu, Rima ;
Cifci, Sule Baz ;
Ispir, Emine Burcin ;
Erturk, Mehmet Ertugrul .
JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH, 2009, 28
[4]   THE EFFECT OF STRONG LONGITUDINAL MAGNETIC-FIELDS ON DOSE DEPOSITION FROM ELECTRON AND PHOTON BEAMS [J].
BIELAJEW, AF .
MEDICAL PHYSICS, 1993, 20 (04) :1171-1179
[5]   POSSIBLE TECHNIQUES IN DIRECT-ELECTRON-BEAM TUMOR THERAPY [J].
BOSTICK, WH .
PHYSICAL REVIEW, 1950, 77 (04) :564-565
[6]   Long-term mortality from heart disease and lung cancer after radiotherapy for early breast cancer: prospective cohort study of about 300 000 women in US SEER cancer registries [J].
Darby, SC ;
McGale, P ;
Taylor, CW ;
Peto, R .
LANCET ONCOLOGY, 2005, 6 (08) :557-565
[7]   The effect of changes in tumor size on breast carcinoma survival in the US: 1975-1999 [J].
Elkin, EB ;
Hudis, C ;
Begg, CB ;
Schrag, D .
CANCER, 2005, 104 (06) :1149-1157
[8]  
Esmaeeli A. D., INT J RAD R IN PRESS
[9]  
Fallone B, 2007, AAPM MINN 49 ANN M
[10]   First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system [J].
Fallone, B. G. ;
Murray, B. ;
Rathee, S. ;
Stanescu, T. ;
Steciw, S. ;
Vidakovic, S. ;
Blosser, E. ;
Tymofichuk, D. .
MEDICAL PHYSICS, 2009, 36 (06) :2084-2088