Cup Press Fit in Uncemented THA Depends on Sex, Acetabular Shape, and Surgical Technique

被引:31
作者
Garcia-Rey, Eduardo [1 ]
Garcia-Cimbrelo, Eduardo [1 ]
Cruz-Pardos, Ana [1 ]
机构
[1] Hosp La Paz Idi Paz, Dept Orthopaed, Madrid 28046, Spain
关键词
TOTAL HIP-ARTHROPLASTY; 10-YEAR FOLLOW-UP; SCREW FIXATION; RADIOGRAPHIC ANALYSIS; COMPONENT; POLYETHYLENE; WEAR; SURVIVORSHIP; REPLACEMENT; STABILITY;
D O I
10.1007/s11999-012-2381-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Uncemented press-fit cups provide bone fixation in primary THA, but the use of screws is sometimes necessary to achieve primary stability of the socket. However, it is unclear whether and when screws should be used. Question/Purposes We analyzed the factors related to screw use with a press-fit uncemented cup and assessed whether screw use is associated with the same rates of loosening and revision as a press-fit technique. Methods We retrospectively reviewed 248 patients who underwent THA using the same prosthetic design. Eighty-eight hips had screws to achieve primary cup fixation (Group 1), and 189 did not (Group 2). Mean age was 50 years (range, 14-73 years). We analyzed factors related to the patient, acetabular type, and reconstruction of the rotation center of the hip. Minimum followup was 5 years (mean, 8.9 years; range, 5-12 years). Results We found higher screw use in women, patients with less physical activity, Acetabular Types A or C, and a distance from the center of the prosthetic femoral head to the normal center of rotation of more than 3 mm. There were four revisions in Group 1 and five in Group 2. Eight hips had radiographic loosening in Group 1 and nine in Group 2. Cups with a postoperative abduction angle of more than 50 degrees had a higher risk for loosening. Conclusions Press fit was achieved less frequently in women and patients with Acetabular Types A or C and less physical activity; a closer distance to the normal center of rotation decreased screw use. Screw use to augment fixation achieved survival similar to that of a press-fit cup. Level of Evidence Level II, prognostic study. See Instructions for Authors for a complete description of levels of evidence
引用
收藏
页码:3014 / 3023
页数:10
相关论文
共 42 条
[1]   Neurovascular injury - Avoiding catastrophe [J].
Barrack, RL .
JOURNAL OF ARTHROPLASTY, 2004, 19 (04) :104-107
[2]  
Bizot P, 2001, CLIN ORTHOP RELAT R, P85
[3]   The Harris-Galante porous-coated acetabular component with screw fixation - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :66-73
[4]   FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS [J].
DAUBIGNE, RM ;
POSTEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) :451-475
[5]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[6]   Three-dimensional polyethylene wear of a press-fit titanium prosthesis - Factors influencing generation of polyethylene debris [J].
Devane, PA ;
Horne, JG ;
Martin, K ;
Coldham, G ;
Krause, B .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :256-266
[7]  
Dorr LD, 1998, CLIN ORTHOP RELAT R, P158
[8]   Radiographic anatomic structure of the arthritic acetabulum and its influence on total hip arthroplasty [J].
Dorr, LD ;
Bechtol, CO ;
Watkins, RG ;
Wan, ZN .
JOURNAL OF ARTHROPLASTY, 2000, 15 (07) :890-900
[9]   STRUCTURAL AND CELLULAR ASSESSMENT OF BONE QUALITY OF PROXIMAL FEMUR [J].
DORR, LD ;
FAUGERE, MC ;
MACKEL, AM ;
GRUEN, TA ;
BOGNAR, B ;
MALLUCHE, HH .
BONE, 1993, 14 (03) :231-242
[10]   Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation [J].
Engh, CA ;
Hopper, RH ;
Engh, CA .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :54-60